Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Physics Conference Series

Amplifier development for multiplexed cryogenic detectors

M. Kiviranta

Published Dec 17, 2012• 2 citations
Publisher

Abstract

We make some considerations on the question of driving the cable from the cryogenic stage of refrigerators to the room temperature, in the case of multiplexed detector array systems where a high total Shannon information capacity is required. We have constructed large SQUID arrays for the purpose, some of which exhibit lower than 5 × 10 −8 Φ 0 Hz −1/2 flux noise at 4.2 K and do not require magnetic shielding in a typical laboratory environment. The option of using class-D amplifiers to reduce the cryogenic heat load is briefly reviewed.

DOI
10.1088/1742-6596/400/5/052014

Related papers

Two-stage locally linearized SQUID readout for frequency domain multiplexed calorimeter arrays

M. Kiviranta, Leif Grönberg, Hannu Sipola

We have constructed a two-stage SQUID amplifier intended for multiplexed cryogenic detector arrays. The upper SQUID is a locally linearized 6 × 80 array showing 0.13 μΦ 0 Hz − 1/2 flux noise at 4.2 K. The lower linearized 4 × 3 SQUID array has decoupled input and feedback coils and shows 0.28 μΦ 0 Hz − 1/2 flux noise at 4.2 K. Design principles and measured performance are reviewed.

Superconductor Science and Technology•Jan 27, 2011•17 citations

The Microwave SQUID Multiplexer

J. A. B. Mates

This thesis describes a multiplexer of Superconducting Quantum Interference Devices (SQUIDs) with low-noise, ultra-low power dissipation, and great scalability. The multiplexer circuit measures the magnetic flux in a large number of unshunted rf SQUIDs by coupling each SQUID to a superconducting microwave resonator tuned to a unique resonance frequency and driving the resonators from a common feedline. A superposition of microwave tones measures each SQUID simultaneously using only two coaxial cables between the cryogenic device and room temperature. This multiplexer will enable the instrumentation of arrays with hundreds of thousands of low-temperature detectors for new applications in cosmology, materials analysis, and nuclear non-proliferation.\nThe driving application of the Microwave SQUID Multiplexer is the readout of large arrays of superconducting transition-edge sensors, by some figures of merit the most sensitive detectors of electromagnetic signals over a span of more than nine orders of magnitude in energy, from 40 GHz microwaves to 200 keV gamma rays. Modern transition-edge sensors have noise-equivalent power as low as 10-20 W / [square root] Hz and energy resolution as good as 2 eV at 6 keV. These per-pixel sensitivities approach theoretical limits set by the underlying signals, motivating a rapid increase in pixel count to access new science. Compelling applications, like the non-destructive assay of nuclear material for treaty verification or the search for primordial gravity waves from inflation use arrays of these detectors to increase collection area or tile a focal plane.\nWe developed three generations of SQUID multiplexers, optimizing the first for flux noise (0.17 mu Phi0 / [square root] Hz) the second for input current noise (19 pA / [square root] Hz) and the last for practical multiplexing of large arrays of cosmic microwave background polarimeters based on transition-edge sensors. Using the last design we demonstrated multiplexed readout of prototype polarimeters with the performance required for the future development of a large-scale astronomical instrument.

•Dec 1, 2011•43 citations

A post-SQUID ac amplifier aimed for multiplexed detector readouts

M. Kiviranta, Antti Virtanen, Heikki Seppä +3 more

We have built a room temperature amplifier based on Si JFETs (junction field effect transistors) intended for ac-coupled SQUID (superconducting quantum interference device) readouts, such as in frequency-domain multiplexed transition-edge sensor systems. The amplifier operates at 5M Hzcentre frequency where it has the measured noise temperature of 27 K for a 60 � load, which includes the noise from the active termination and the room temperature transformer. When it was driven from a SQUID with an on-chip matching transformer, flux noise of 0.45 µ� 0 Hz −1/2 was obtained. Additionally, w ec onsider the potential o ft he recently introduced SiGe bipolar transistors for the same application. The dynamic range considerations for SQUID multiplexers, which require the use of an amplifier with a low noise temperature, are briefly discussed. (Some figures in this article are in colour only in the electronic version)

Superconductor Science and Technology•Mar 16, 2006•6 citations

Nearly Quantum Limited Two-Stage SQUID Amplifiers for the Frequency Domain Multiplexing of TES Based X-ray and Infrared Detectors

Luciano G. Gottardi, M. Kiviranta, Jan van der Kuur +3 more

The frequency domain multiplexing (FDM) readout of arrays of transition edges sensors for the X-IFU/Athena and SAFARI/SPICA instruments requires SQUID amplifiers with low input inductance, low flux noise, high-dynamic range and low power consumption. We report the performance of two-stage SQUID amplifiers developed at VTT coupled to multiple high-Q LC resonators of the SRON FDM readout operating in the frequency range from 2 to 5 MHz. The SQUIDs have been tested in the following configurations: 1) the two SQUIDs at base temperature with open input; 2) the amplifier SQUID at 1K temperature and the front-end SQUID at base temperature in the FDM readout of low-G TES bolometers; and 3) and in the FDM readout of X-ray microcalorimeter arrays with both SQUIDS at base temperature. We measured an input flux noise equal to 0.18 μΦ0/Hz1/2at 20 mK, equivalent to an energy resolution of 9 b. The measured current noise at the SQUID input is ~1 pA/Hz1/2at 20 mK, which corresponds to a coupled energy resolution of about 15 b.

IEEE Transactions on Applied Superconductivity•Nov 10, 2014•15 citations

An X-band SQUID Multiplexer

Inseob Hahn, Bruce Bumble, Henry George LeDuc +2 more

We are developing a microwave readout multiplexer for arrays of superconducting quantum interference devices (SQUIDs). A series of microwave resonators with frequencies ∼10 GHz are each loaded by a dc SQUID to a degree that depends on the flux state of the SQUID. By using resonators with high quality factors and slightly different resonance frequencies, many of these resonator‐coupled SQUIDs may be read out with a single excitation line and cryogenic amplifier. Our multiplexer is similar to the one demonstrated by Irwin and Lehnert except for the use of higher‐frequency, fully‐lithographed transmission line resonators. We discuss a technique for modulating the SQUID array in series that alleviates the need to individually flux‐bias the SQUIDs. The multiplexer has applications to the readout of detector arrays for astronomy as well as medical magnetic imaging.

AIP conference proceedings•Jan 1, 2006•4 citations

Evaluation of a Microwave SQUID Multiplexer Prototype

Konrad W. Lehnert, K. D. Irwin, Manuel A. Castellanos-Beltran +2 more

As large arrays of ultrasensitive cryogenic detectors of radiant energy are developed, multiplexing schemes are required to manage system complexity. Any such scheme must also meet stringent sensitivity, bandwidth, dynamic range and power dissipation specifications. We describe preliminary tests of a microwave frequency-division multiplexed readout of SQUID amplifiers. From these initial tests we estimated the number of SQUIDs that can be multiplexed with this scheme and the sensitivity and bandwidth of each SQUID amplifier.

IEEE Transactions on Applied Superconductivity•Jun 1, 2007•18 citations
We make some considerations on the question of driving the cable from the cryogenic stage of refrigerators to the room temperature, in the case of multiplexed detector array systems where a high total Shannon information capacity is required. We have constructed large SQUID arrays for the purpose, some of which exhibit lower than 5 × 10 −8 Φ 0 Hz −1/2 flux noise at 4.2 K and do not require magnetic shielding in a typical laboratory environment. The option of using class-D amplifiers to reduce the cryogenic heat load is briefly reviewed.
This thesis describes a multiplexer of Superconducting Quantum Interference Devices (SQUIDs) with low-noise, ultra-low power dissipation, and great scalability. The multiplexer circuit measures the magnetic flux in a large number of unshunted rf SQUIDs by coupling each SQUID to a superconducting microwave resonator tuned to a unique resonance frequency and driving the resonators from a common feedline. A superposition of microwave tones measures each SQUID simultaneously using only two coaxial cables between the cryogenic device and room temperature. This multiplexer will enable the instrumentation of arrays with hundreds of thousands of low-temperature detectors for new applications in cosmology, materials analysis, and nuclear non-proliferation.\nThe driving application of the Microwave SQUID Multiplexer is the readout of large arrays of superconducting transition-edge sensors, by some figures of merit the most sensitive detectors of electromagnetic signals over a span of more than nine orders of magnitude in energy, from 40 GHz microwaves to 200 keV gamma rays. Modern transition-edge sensors have noise-equivalent power as low as 10-20 W / [square root] Hz and energy resolution as good as 2 eV at 6 keV. These per-pixel sensitivities approach theoretical limits set by the underlying signals, motivating a rapid increase in pixel count to access new science. Compelling applications, like the non-destructive assay of nuclear material for treaty verification or the search for primordial gravity waves from inflation use arrays of these detectors to increase collection area or tile a focal plane.\nWe developed three generations of SQUID multiplexers, optimizing the first for flux noise (0.17 mu Phi0 / [square root] Hz) the second for input current noise (19 pA / [square root] Hz) and the last for practical multiplexing of large arrays of cosmic microwave background polarimeters based on transition-edge sensors. Using the last design we demonstrated multiplexed readout of prototype polarimeters with the performance required for the future development of a large-scale astronomical instrument.
We have built a room temperature amplifier based on Si JFETs (junction field effect transistors) intended for ac-coupled SQUID (superconducting quantum interference device) readouts, such as in frequency-domain multiplexed transition-edge sensor systems. The amplifier operates at 5M Hzcentre frequency where it has the measured noise temperature of 27 K for a 60 � load, which includes the noise from the active termination and the room temperature transformer. When it was driven from a SQUID with an on-chip matching transformer, flux noise of 0.45 µ� 0 Hz −1/2 was obtained. Additionally, w ec onsider the potential o ft he recently introduced SiGe bipolar transistors for the same application. The dynamic range considerations for SQUID multiplexers, which require the use of an amplifier with a low noise temperature, are briefly discussed. (Some figures in this article are in colour only in the electronic version)
The frequency domain multiplexing (FDM) readout of arrays of transition edges sensors for the X-IFU/Athena and SAFARI/SPICA instruments requires SQUID amplifiers with low input inductance, low flux noise, high-dynamic range and low power consumption. We report the performance of two-stage SQUID amplifiers developed at VTT coupled to multiple high-Q LC resonators of the SRON FDM readout operating in the frequency range from 2 to 5 MHz. The SQUIDs have been tested in the following configurations: 1) the two SQUIDs at base temperature with open input; 2) the amplifier SQUID at 1K temperature and the front-end SQUID at base temperature in the FDM readout of low-G TES bolometers; and 3) and in the FDM readout of X-ray microcalorimeter arrays with both SQUIDS at base temperature. We measured an input flux noise equal to 0.18 μΦ0/Hz1/2at 20 mK, equivalent to an energy resolution of 9 b. The measured current noise at the SQUID input is ~1 pA/Hz1/2at 20 mK, which corresponds to a coupled energy resolution of about 15 b.
We are developing a microwave readout multiplexer for arrays of superconducting quantum interference devices (SQUIDs). A series of microwave resonators with frequencies ∼10 GHz are each loaded by a dc SQUID to a degree that depends on the flux state of the SQUID. By using resonators with high quality factors and slightly different resonance frequencies, many of these resonator‐coupled SQUIDs may be read out with a single excitation line and cryogenic amplifier. Our multiplexer is similar to the one demonstrated by Irwin and Lehnert except for the use of higher‐frequency, fully‐lithographed transmission line resonators. We discuss a technique for modulating the SQUID array in series that alleviates the need to individually flux‐bias the SQUIDs. The multiplexer has applications to the readout of detector arrays for astronomy as well as medical magnetic imaging.
As large arrays of ultrasensitive cryogenic detectors of radiant energy are developed, multiplexing schemes are required to manage system complexity. Any such scheme must also meet stringent sensitivity, bandwidth, dynamic range and power dissipation specifications. We describe preliminary tests of a microwave frequency-division multiplexed readout of SQUID amplifiers. From these initial tests we estimated the number of SQUIDs that can be multiplexed with this scheme and the sensitivity and bandwidth of each SQUID amplifier.