Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Superconductor Science and Technology

A post-SQUID ac amplifier aimed for multiplexed detector readouts

M. Kiviranta, Antti Virtanen, Heikki Seppä, Jari S Penttilä, Juha Hassel, P. Helistö

Published Mar 16, 2006• 6 citations
Publisher

Abstract

We have built a room temperature amplifier based on Si JFETs (junction field effect transistors) intended for ac-coupled SQUID (superconducting quantum interference device) readouts, such as in frequency-domain multiplexed transition-edge sensor systems. The amplifier operates at 5M Hzcentre frequency where it has the measured noise temperature of 27 K for a 60 � load, which includes the noise from the active termination and the room temperature transformer. When it was driven from a SQUID with an on-chip matching transformer, flux noise of 0.45 µ� 0 Hz −1/2 was obtained. Additionally, w ec onsider the potential o ft he recently introduced SiGe bipolar transistors for the same application. The dynamic range considerations for SQUID multiplexers, which require the use of an amplifier with a low noise temperature, are briefly discussed. (Some figures in this article are in colour only in the electronic version)

DOI
10.1088/0953-2048/19/5/s43

Related papers

Nearly Quantum Limited Two-Stage SQUID Amplifiers for the Frequency Domain Multiplexing of TES Based X-ray and Infrared Detectors

Luciano G. Gottardi, M. Kiviranta, Jan van der Kuur +3 more

The frequency domain multiplexing (FDM) readout of arrays of transition edges sensors for the X-IFU/Athena and SAFARI/SPICA instruments requires SQUID amplifiers with low input inductance, low flux noise, high-dynamic range and low power consumption. We report the performance of two-stage SQUID amplifiers developed at VTT coupled to multiple high-Q LC resonators of the SRON FDM readout operating in the frequency range from 2 to 5 MHz. The SQUIDs have been tested in the following configurations: 1) the two SQUIDs at base temperature with open input; 2) the amplifier SQUID at 1K temperature and the front-end SQUID at base temperature in the FDM readout of low-G TES bolometers; and 3) and in the FDM readout of X-ray microcalorimeter arrays with both SQUIDS at base temperature. We measured an input flux noise equal to 0.18 μΦ0/Hz1/2at 20 mK, equivalent to an energy resolution of 9 b. The measured current noise at the SQUID input is ~1 pA/Hz1/2at 20 mK, which corresponds to a coupled energy resolution of about 15 b.

IEEE Transactions on Applied Superconductivity•Nov 10, 2014•15 citations

SiGe Integrated Circuit∕SQUID Hybrid Cryogenic Multiplexer for Superconducting Bolometer Array

D. Prêle, Fabrice Voisin, R. Oger +6 more

The development of large superconducting bolometer (Transition Edge Sensor: TES) arrays requires ultra low noise amplification and multiplexing electronics. The use of a first transducer stage such as a SQUID (Superconducting QUantum Interference Device) allows ultimate performance in terms of noise. However, the linearization of the SQUID characteristic requires low noise amplification. Furthermore, to realize a time domain multiplexer with SQUIDs, switched biasing is also needed. We have designed an Integrated Circuit (IC) in standard BiCMOS SiGe technology for the readout and the control of a SQUID multiplexer. It includes a low noise amplifier with multiplexed inputs, switched current sources for SQUIDs, and digital circuit for the addressing with only one room temperature clock signal. We have successfully tested this integrated circuit down to 2 K. To validate the operation of a SQUID multiplexer controlled by this SiGe cryogenic IC, we have developed a 2×2 SQUID hybrid demonstrator. It consists of four commercial SQUIDs connected to a SiGe IC.

AIP conference proceedings•Jan 1, 2009•3 citations

A frequency-domain SQUID multiplexer for arrays of transition-edge superconducting sensors

Trevor M. Lanting, Hsiao-Mei Cho, John L. Clarke +5 more

We describe the development of a frequency-domain multiplexer (MUX) to read out arrays of superconducting transition-edge sensors (TES). Fabrication of large-format arrays of these sensors is becoming practical; however, reading out each sensor in the array is a major instrumental challenge. Frequency-domain multiplexing can greatly simplify the instrumentation of large arrays by reducing the number of SQUID's (superconducting quantum interference devices) and wires to the low temperature stages. Each sensor is AC biased at a different frequency, ranging from 380 kHz to 1 MHz. Each sensor signal amplitude-modulates its respective AC bias frequency. An LC filter associated with each sensor suppresses Johnson noise from the other sensors. The signals are combined at a current summing node and measured by a single SQUID. The individual signals from each sensor are then lock-in detected by room temperature electronics. Test chips with fully lithographed LC filters for up to 32 channels have been designed and fabricated. The capacitance and inductance values have been measured and are close to the design goals. We discuss the basic principles of frequency-domain multiplexing, the design and testing of the test chips, and the implementation of a practical system.

IEEE Transactions on Applied Superconductivity•Jun 1, 2003•20 citations

Dc and un SQUID's for readout of ac-biased transition-edge sensors

M. Kiviranta, Jari S Penttilä, Leif Grönberg +2 more

We have developed a set of SQUIDs optimized for readout of ac-biased transition edge sensors. Junction shunts are made of Pd and attached to cooling fins to facilitate low-noise operation at sub-kelvin temperatures. SQUID's have a low loop inductance in order to reach a large natural dynamic range even without negative feedback. The SQUIDs are intended to be used for frequency-domain multiplexing of X-ray calorimeter arrays. Both traditional dc-SQUIDs and novel un-SQUIDs are manufactured. The fabrication process and SQUID design criteria are reviewed.

IEEE Transactions on Applied Superconductivity•Jun 1, 2003•11 citations

Very low noise, tightly coupled, dc SQUID amplifiers

B. Muhlfelder, J. A. Beall, Michael W. Cromar +1 more

We have fabricated and tested thin film, niobium edge junction, double transformer, dc superconducting quantum interference devices (SQUID’s) that were stable under room-temperature storage and thermal cycling and that had very good noise performance. The input inductance, approximately 1.7 μH, was large enough to facilitate good matching to many experiments. When the SQUID was operated as a small-signal amplifier, the minimum detectable energy per unit bandwidth (Se) was 5×10−33 J/Hz at 100 kHz, referred to the SQUID loop (uncoupled). The minimum detectable energy per unit bandwidth was 1.8×10−31 J/Hz at 100 kHz, referred to the input coil. The SQUID’s had good characteristics for flux-locked operation since the small signal Se was low over a substantial range of bias current and magnetic flux. For operation in a flux-locked feedback circuit, Se was 6×10−32 J/Hz at 1 kHz.

Applied Physics Letters•Oct 27, 1986•19 citations

Low-noise ultra-high-speed dc SQUID readout electronics

D. Drung, Colmar Hinnrichs, H.-J. Barthelmess

User-friendly ultra-high-speed readout electronics for dc superconducting quantum interference devices (SQUIDs) are presented. To maximize the system bandwidth, the SQUID is directly read out without flux modulation. A composite preamplifier is used consisting of a slow dc amplifier in parallel with a fast ac amplifier. In this way, excellent dc precision and a high amplifier bandwidth of 50 MHz are achieved, simultaneously. A virtual 50 Ω amplifier input resistance with negligible excess noise is realized by active shunting, i.e., by applying feedback from preamplifier output to input via a high resistance. The white voltage and current noise levels are 0.33 nV Hz −1 and 2.6 pA Hz −1/2 , respectively. The electronics is fully computer controlled via a microcontroller integrated into the flux-locked loop (FLL) board. Easy-to-use software makes the various electronic settings accessible. A wide bias voltage range of 1.3 mV enables the readout of series SQUID arrays. Furthermore, additional current sources allow the operation of two-stage SQUIDs or transition edge sensors. The electronics was tested using various SQUIDs with input inductances between 30 nH and 1.5 µH. Typically, the maximum FLL bandwidth was 20 MHz, which is close to the theoretical limit given by transmission line delay within the FLL. Slew rates of up to 4.6 Φ 0 µs −1 were achieved with series SQUID arrays. Current noise levels as low as 0.47 pA Hz −1/2 and coupled energy sensitivities between 90 h and 500 h were measured at 4.2 K, where h is the Planck constant. The noise did not degrade when the system bandwidth was increased to the maximum value of about 20 MHz. With a two-stage set-up, intrinsic white energy sensitivities of 30 h and 2.3 h were measured at 4.2 and 0.3 K, respectively.

Superconductor Science and Technology•Feb 27, 2006•76 citations
We have built a room temperature amplifier based on Si JFETs (junction field effect transistors) intended for ac-coupled SQUID (superconducting quantum interference device) readouts, such as in frequency-domain multiplexed transition-edge sensor systems. The amplifier operates at 5M Hzcentre frequency where it has the measured noise temperature of 27 K for a 60 � load, which includes the noise from the active termination and the room temperature transformer. When it was driven from a SQUID with an on-chip matching transformer, flux noise of 0.45 µ� 0 Hz −1/2 was obtained. Additionally, w ec onsider the potential o ft he recently introduced SiGe bipolar transistors for the same application. The dynamic range considerations for SQUID multiplexers, which require the use of an amplifier with a low noise temperature, are briefly discussed. (Some figures in this article are in colour only in the electronic version)
The frequency domain multiplexing (FDM) readout of arrays of transition edges sensors for the X-IFU/Athena and SAFARI/SPICA instruments requires SQUID amplifiers with low input inductance, low flux noise, high-dynamic range and low power consumption. We report the performance of two-stage SQUID amplifiers developed at VTT coupled to multiple high-Q LC resonators of the SRON FDM readout operating in the frequency range from 2 to 5 MHz. The SQUIDs have been tested in the following configurations: 1) the two SQUIDs at base temperature with open input; 2) the amplifier SQUID at 1K temperature and the front-end SQUID at base temperature in the FDM readout of low-G TES bolometers; and 3) and in the FDM readout of X-ray microcalorimeter arrays with both SQUIDS at base temperature. We measured an input flux noise equal to 0.18 μΦ0/Hz1/2at 20 mK, equivalent to an energy resolution of 9 b. The measured current noise at the SQUID input is ~1 pA/Hz1/2at 20 mK, which corresponds to a coupled energy resolution of about 15 b.
The development of large superconducting bolometer (Transition Edge Sensor: TES) arrays requires ultra low noise amplification and multiplexing electronics. The use of a first transducer stage such as a SQUID (Superconducting QUantum Interference Device) allows ultimate performance in terms of noise. However, the linearization of the SQUID characteristic requires low noise amplification. Furthermore, to realize a time domain multiplexer with SQUIDs, switched biasing is also needed. We have designed an Integrated Circuit (IC) in standard BiCMOS SiGe technology for the readout and the control of a SQUID multiplexer. It includes a low noise amplifier with multiplexed inputs, switched current sources for SQUIDs, and digital circuit for the addressing with only one room temperature clock signal. We have successfully tested this integrated circuit down to 2 K. To validate the operation of a SQUID multiplexer controlled by this SiGe cryogenic IC, we have developed a 2×2 SQUID hybrid demonstrator. It consists of four commercial SQUIDs connected to a SiGe IC.
We describe the development of a frequency-domain multiplexer (MUX) to read out arrays of superconducting transition-edge sensors (TES). Fabrication of large-format arrays of these sensors is becoming practical; however, reading out each sensor in the array is a major instrumental challenge. Frequency-domain multiplexing can greatly simplify the instrumentation of large arrays by reducing the number of SQUID's (superconducting quantum interference devices) and wires to the low temperature stages. Each sensor is AC biased at a different frequency, ranging from 380 kHz to 1 MHz. Each sensor signal amplitude-modulates its respective AC bias frequency. An LC filter associated with each sensor suppresses Johnson noise from the other sensors. The signals are combined at a current summing node and measured by a single SQUID. The individual signals from each sensor are then lock-in detected by room temperature electronics. Test chips with fully lithographed LC filters for up to 32 channels have been designed and fabricated. The capacitance and inductance values have been measured and are close to the design goals. We discuss the basic principles of frequency-domain multiplexing, the design and testing of the test chips, and the implementation of a practical system.
We have developed a set of SQUIDs optimized for readout of ac-biased transition edge sensors. Junction shunts are made of Pd and attached to cooling fins to facilitate low-noise operation at sub-kelvin temperatures. SQUID's have a low loop inductance in order to reach a large natural dynamic range even without negative feedback. The SQUIDs are intended to be used for frequency-domain multiplexing of X-ray calorimeter arrays. Both traditional dc-SQUIDs and novel un-SQUIDs are manufactured. The fabrication process and SQUID design criteria are reviewed.
We have fabricated and tested thin film, niobium edge junction, double transformer, dc superconducting quantum interference devices (SQUID’s) that were stable under room-temperature storage and thermal cycling and that had very good noise performance. The input inductance, approximately 1.7 μH, was large enough to facilitate good matching to many experiments. When the SQUID was operated as a small-signal amplifier, the minimum detectable energy per unit bandwidth (Se) was 5×10−33 J/Hz at 100 kHz, referred to the SQUID loop (uncoupled). The minimum detectable energy per unit bandwidth was 1.8×10−31 J/Hz at 100 kHz, referred to the input coil. The SQUID’s had good characteristics for flux-locked operation since the small signal Se was low over a substantial range of bias current and magnetic flux. For operation in a flux-locked feedback circuit, Se was 6×10−32 J/Hz at 1 kHz.
User-friendly ultra-high-speed readout electronics for dc superconducting quantum interference devices (SQUIDs) are presented. To maximize the system bandwidth, the SQUID is directly read out without flux modulation. A composite preamplifier is used consisting of a slow dc amplifier in parallel with a fast ac amplifier. In this way, excellent dc precision and a high amplifier bandwidth of 50 MHz are achieved, simultaneously. A virtual 50 Ω amplifier input resistance with negligible excess noise is realized by active shunting, i.e., by applying feedback from preamplifier output to input via a high resistance. The white voltage and current noise levels are 0.33 nV Hz −1 and 2.6 pA Hz −1/2 , respectively. The electronics is fully computer controlled via a microcontroller integrated into the flux-locked loop (FLL) board. Easy-to-use software makes the various electronic settings accessible. A wide bias voltage range of 1.3 mV enables the readout of series SQUID arrays. Furthermore, additional current sources allow the operation of two-stage SQUIDs or transition edge sensors. The electronics was tested using various SQUIDs with input inductances between 30 nH and 1.5 µH. Typically, the maximum FLL bandwidth was 20 MHz, which is close to the theoretical limit given by transmission line delay within the FLL. Slew rates of up to 4.6 Φ 0 µs −1 were achieved with series SQUID arrays. Current noise levels as low as 0.47 pA Hz −1/2 and coupled energy sensitivities between 90 h and 500 h were measured at 4.2 K, where h is the Planck constant. The noise did not degrade when the system bandwidth was increased to the maximum value of about 20 MHz. With a two-stage set-up, intrinsic white energy sensitivities of 30 h and 2.3 h were measured at 4.2 and 0.3 K, respectively.