Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Review of Scientific Instruments

Acousto-optic modulator based frequency stabilized diode laser system for atom trapping

Peter D. McDowall, Mikkel F. Andersen

Published May 1, 2009• 6 citations
Publisher

Abstract

We report on an inexpensive commercial laser diode stabilized to the D(2)-line in rubidium using a simple scheme. The linewidth was reduced to 1.3 MHz without an external cavity, making it suitable for laser cooling and trapping. The system is very robust and the laser frequency can be changed rapidly (within 51 micros) while the laser remains in lock. The frequency of the locked laser drifts less than 850 kHz peak-to-peak over 25 h. We demonstrate laser cooling and trapping using our system.

DOI
10.1063/1.3125029

Related papers

Frequency-stabilized diode laser with the Zeeman shift in an atomic vapor

Kristan L. Corwin, Zheng‐Tian Lu, Carter F. Hand +2 more

We demonstrate a robust method of stabilizing a diode laser frequency to an atomic transition. This technique employs the Zeeman shift to generate an antisymmetric signal about a Doppler-broadened atomic resonance, and therefore offers a large recapture range as well as high stability. The frequency of a 780-nm diode laser, stabilized to such a signal in Rb, drifted less than 0.5 MHz peak-peak (1 part in 10(9)) in 38 h. This tunable frequency lock can be constructed inexpensively, requires little laser power, rarely loses lock, and can be extended to other wavelengths by use of different atomic species.

Applied Optics•May 20, 1998•381 citations

Laser system for frequency domain velocimetry and atom interferometry experiments

J. Randhawa, G. Carlse, M. B. Llaguno +5 more

We discuss the characterization and specifications of a home-built external cavity diode laser system that is suitable for frequency-domain cold-atom velocimetry and measurements of gravitational acceleration. The laser system is frequency stabilized using a modulation-free technique that lowers the temperature of a magneto-optical trap (MOT) in comparison with a MOT realized using a laser that relies on lock-in spectroscopy. The laser system also incorporates a feedback loop involving an acousto-optic modulator for intensity stabilization, which reduces the effect of low frequency vibrations. By integrating this laser with a home-built, dual-output radio frequency synthesizer, we are able to derive two laser beams with a precisely controlled relative detuning for frequency domain interferometry using laser-cooled atoms. The detuning can range from the mHz to the MHz level with a stability of 10 μHz.

Review of Scientific Instruments•Dec 1, 2025•1 citation

Sub-megahertz laser stabilization by harnessing orthogonality between the acousto-optic modulator dither and atomic spectroscopy

Phatwarach Siriworakoonchai, Parinya Udommai, Nuttanan Tanasanchai +1 more

A sub-MHz frequency stability of the laser is crucial in the quantum-atom experiment where precise atomic transition is required for control and manipulation of atom like in the atom quantum computing. In this work, we have built the frequency stabilization system for the lasers used in our cold Rubidium atom experiment in the magneto-optical trap (MOT) and the optical tweezers. We utilized a Rubidium vapour glass cell as a frequency reference, which provides atomically absolute reference point with low complexity setup. By mean of the absorption of the laser beam by the Rubidium vapour, the saturated absorption spectroscopy (SAS) experiment was setup to produce the D2 line spectra. The acousto-optic modulator (AOM) was used to sinusoidally dither the laser frequency and consequently the resonance peaks in the spectra. Detailing in this work, the AOM sinusoidal dithering and the dithered SAS signal had orthogonality and were processed together to produce the error signal used to stabilize the laser frequency to the resonant peak. This frequency stabilization system achieved the frequency standard deviation below 0.80 MHz over up to 8 min 00 period. The system also allowed for stabilized frequency tunability over a range of 55 - 60 MHz about the target resonance peak. This performance is significant for stabilizing the lasers in the MOT experiment and related quantum-atom research.

Results in Optics•Oct 28, 2025•4 citations

Frequency stabilized diode laser with variable linewidth at a wavelength of 4047 nm

Benjamin Rein, Thomas Walther

We report on a frequency stabilized laser system with a variable linewidth at a wavelength of 404.7 nm used as an incoherent repump on the 6P30↔7S31 transition in mercury. By directly modulating the laser diode current with Gaussian white noise, the laser linewidth can be broadened up to 68 MHz. A Doppler-free dichroic atomic vapor laser lock spectroscopy provides an error signal suitable for frequency stabilization even for the broadened laser. Without the need of an acousto-optic modulator for the linewidth tuning or lock-in technique for frequency stabilization, this laser system provides an inexpensive approach for an incoherent and highly efficient repumper in atomic experiments.

Optics Letters•Apr 3, 2017•5 citations

A narrow linewidth diode laser system for strontium laser cooling applications

Sarah Nagel

The diode laser system for laser cooling on the 1S 0 → 3P1 intercombination line of strontium discussed in this thesis allows us to cool and trap an atomic strontium sample to 15 muK. Samples in this temperature range are useful for the development of the next generation of atomic frequency standards, cold collision studies, and as a step towards quantum degeneracy. This laser system consists of a Littrow configuration external-cavity diode laser, which is frequency locked to a high finesse cavity. The cavity is subsequently locked to an absorption feature to produce a few mW of tunable, stabilized, single mode power at the target wavelength. We present the design and characterization of this system, including a linewidth measurement of 70 kHz, as well as preliminary results from cooling and trapping.

•Jan 1, 2004•1 citation

Laser Frequency Stabilization for Narrow Linewidth Cooling of Lithium-6

Adam Reed

Laser cooling to micro-Kelvin temperatures requires a laser with active frequency stabilization. The linewidth of an atomic transition sets a lower bound on the Doppler cooling temperature. The 2s-2p transition in lithium-6 has a Doppler temperature of ~140 μK In contrast, the 2s-3p transition has a narrower linewidth and thus provides a lower temperature limit of ~20 μK. We present a method for stabilizing a laser to an atomic line in a vapor cell using modulation transfer spectroscopy and a home-built lock-in amplifier. Our results demonstrate successful locking of a 323 nm laser to the 2s-3p transition. The stabilized laser provides a second stage of magneto-optical trapping that results in a factor of ∼5 increase in the phase space density before evaporating to degeneracy in an optical dipole trap.

•Mar 1, 2011•0 citations
We report on an inexpensive commercial laser diode stabilized to the D(2)-line in rubidium using a simple scheme. The linewidth was reduced to 1.3 MHz without an external cavity, making it suitable for laser cooling and trapping. The system is very robust and the laser frequency can be changed rapidly (within 51 micros) while the laser remains in lock. The frequency of the locked laser drifts less than 850 kHz peak-to-peak over 25 h. We demonstrate laser cooling and trapping using our system.
We demonstrate a robust method of stabilizing a diode laser frequency to an atomic transition. This technique employs the Zeeman shift to generate an antisymmetric signal about a Doppler-broadened atomic resonance, and therefore offers a large recapture range as well as high stability. The frequency of a 780-nm diode laser, stabilized to such a signal in Rb, drifted less than 0.5 MHz peak-peak (1 part in 10(9)) in 38 h. This tunable frequency lock can be constructed inexpensively, requires little laser power, rarely loses lock, and can be extended to other wavelengths by use of different atomic species.
We discuss the characterization and specifications of a home-built external cavity diode laser system that is suitable for frequency-domain cold-atom velocimetry and measurements of gravitational acceleration. The laser system is frequency stabilized using a modulation-free technique that lowers the temperature of a magneto-optical trap (MOT) in comparison with a MOT realized using a laser that relies on lock-in spectroscopy. The laser system also incorporates a feedback loop involving an acousto-optic modulator for intensity stabilization, which reduces the effect of low frequency vibrations. By integrating this laser with a home-built, dual-output radio frequency synthesizer, we are able to derive two laser beams with a precisely controlled relative detuning for frequency domain interferometry using laser-cooled atoms. The detuning can range from the mHz to the MHz level with a stability of 10 μHz.
A sub-MHz frequency stability of the laser is crucial in the quantum-atom experiment where precise atomic transition is required for control and manipulation of atom like in the atom quantum computing. In this work, we have built the frequency stabilization system for the lasers used in our cold Rubidium atom experiment in the magneto-optical trap (MOT) and the optical tweezers. We utilized a Rubidium vapour glass cell as a frequency reference, which provides atomically absolute reference point with low complexity setup. By mean of the absorption of the laser beam by the Rubidium vapour, the saturated absorption spectroscopy (SAS) experiment was setup to produce the D2 line spectra. The acousto-optic modulator (AOM) was used to sinusoidally dither the laser frequency and consequently the resonance peaks in the spectra. Detailing in this work, the AOM sinusoidal dithering and the dithered SAS signal had orthogonality and were processed together to produce the error signal used to stabilize the laser frequency to the resonant peak. This frequency stabilization system achieved the frequency standard deviation below 0.80 MHz over up to 8 min 00 period. The system also allowed for stabilized frequency tunability over a range of 55 - 60 MHz about the target resonance peak. This performance is significant for stabilizing the lasers in the MOT experiment and related quantum-atom research.
We report on a frequency stabilized laser system with a variable linewidth at a wavelength of 404.7 nm used as an incoherent repump on the 6P30↔7S31 transition in mercury. By directly modulating the laser diode current with Gaussian white noise, the laser linewidth can be broadened up to 68 MHz. A Doppler-free dichroic atomic vapor laser lock spectroscopy provides an error signal suitable for frequency stabilization even for the broadened laser. Without the need of an acousto-optic modulator for the linewidth tuning or lock-in technique for frequency stabilization, this laser system provides an inexpensive approach for an incoherent and highly efficient repumper in atomic experiments.
The diode laser system for laser cooling on the 1S 0 → 3P1 intercombination line of strontium discussed in this thesis allows us to cool and trap an atomic strontium sample to 15 muK. Samples in this temperature range are useful for the development of the next generation of atomic frequency standards, cold collision studies, and as a step towards quantum degeneracy. This laser system consists of a Littrow configuration external-cavity diode laser, which is frequency locked to a high finesse cavity. The cavity is subsequently locked to an absorption feature to produce a few mW of tunable, stabilized, single mode power at the target wavelength. We present the design and characterization of this system, including a linewidth measurement of 70 kHz, as well as preliminary results from cooling and trapping.
Laser cooling to micro-Kelvin temperatures requires a laser with active frequency stabilization. The linewidth of an atomic transition sets a lower bound on the Doppler cooling temperature. The 2s-2p transition in lithium-6 has a Doppler temperature of ~140 μK In contrast, the 2s-3p transition has a narrower linewidth and thus provides a lower temperature limit of ~20 μK. We present a method for stabilizing a laser to an atomic line in a vapor cell using modulation transfer spectroscopy and a home-built lock-in amplifier. Our results demonstrate successful locking of a 323 nm laser to the 2s-3p transition. The stabilized laser provides a second stage of magneto-optical trapping that results in a factor of ∼5 increase in the phase space density before evaporating to degeneracy in an optical dipole trap.