Symposium on Frequency Standards and Metrology

SYSTEMATIC FREQUENCY SHIFTS AND QUANTUM PROJECTION NOISE IN NIST-F1

Steven R. Jefferts, Thomas P. Heavner, J.H. Shirley, T.E. Parker

Published May 1, 2002• 3 citations
Publisher

Abstract

We present results from NIST-F1, the NIST primary frequency standard, a Cesium atomic fountain. In particular we give the results of the latest frequency evaluation which has a combined standard fractional frequency uncertainty of 1.3 × 10 -15 in the laboratory and a total uncertainty of 1.5 × 10 -15 including the time transfer to the Bureau International des Poids et Mesures (BIPM) international atomic time scale (TAI). We also present results that demonstrate the attainment of the quantum projection noise limit in this fountain.

DOI
10.1142/9789812777713_0010

Related papers

Quantum Projection Noise in an Atomic Fountain: A High Stability Cesium Frequency Standard

Giorgio Santarelli, Philippe Laurent, P. Lemonde +5 more

We describe the operation of a laser cooled cesium fountain clock in the quantum limited regime. An ultrastable cryogenic sapphire oscillator is used to measure the short-term frequency stability of the fountain as a function of the number of detected atoms ${N}_{\mathrm{at}}$. For ${N}_{\mathrm{at}}$ varying from $4\ifmmode\times\else\texttimes\fi{}{10}^{4}$ to $6\ifmmode\times\else\texttimes\fi{}{10}^{5}$ the Allan standard deviation of the frequency fluctuations is in excellent agreement with the ${N}_{\mathrm{at}}^{\ensuremath{-}1/2}$ law of atomic projection noise. With $6\ifmmode\times\else\texttimes\fi{}{10}^{5}$ atoms, the relative frequency stability is $4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$, where \ensuremath{\tau} is the integration time in seconds. This is the best short-term stability ever reported for primary frequency standards, a factor of 5 improvement over previous results.

Physical Review Letters•Jun 7, 1999•569 citations

Article

Marie-Claude Gagné, J.-S. Boulanger, R.J. Douglas

The accelerated development of laser methods for manipulating the internal state and motion of atoms, and the recent primary evaluation in France of a cesium frequency standard using cold atoms in an atomic fountain configuration, allow the frontiers of time metrology, accuracy, and stability to be pushed near parts in the 1016 level, a factor of 100 over the present primary laboratory clocks. These positive results revived the development of more accurate cesium atomic clocks, and the Institute of National Measurement Standards (INMS), of the National Research Council of Canada (NRC) is undertaking a cesium-fountain project aimed at reaching these new levels of accuracy and stability. This paper reviews its present status. To appreciate the considerable impact of cold atoms in time and frequency metrology, we begin by recalling the background principles of traditional cesium frequency standards, their typical performance and main limitations. After introducing the important theoretical results essential to understanding the techniques of laser cooling and magneto-optical trapping, we focus on describing the characterization and control of our magneto-optical trap (MOT) and report the parameters that allow us to fill the trap with a few million atoms in less than a second and cool them to a temperature lower than 5 muK using optical molasses. We will describe the specifics of our cesium-fountain prototype, which operates with a 2-dimensional moving molasses. This special configuration is applicable for multipulse operation of the fountain, which can greatly relax the local oscillator requirements for time keeping. Finally, progress toward our objective of launching cooled atoms, at a rate of one ensemble per second, at speeds of 7 m/s, for a fountain with an interrogation time of about 1 s, will be analysed.PACS Nos.: 06.20, 06.30, and 32.80P

Canadian Journal of Physics•Jan 1, 1998•1 citation

Absolute frequency measurement of a $^{176}$Lu$^+\,(^{3}\mathrm{D}_1)$ standard against the NRC-FCs2 fountain with $2.6\times10^{-16}$ uncertainty

K. J. Arnold, Bin Jian, Zhao Zhang +6 more

We report an improved absolute frequency measurement of the $^{176}$Lu$^+\,(^{3}\mathrm{D}_1)$ optical frequency standard, evaluated via a remote link to the NRC-FCs2 caesium fountain primary frequency standard. Operating a single ion clock with 94.2% uptime over 10 days, and using an ambiguity-resolved precise point positioning (PPP-AR) link over the Global Positioning System, we determine an absolute frequency of $353\,638\,794\,073\,800.332(91)\,$Hz at a fractional uncertainty of $2.6 \times 10^{-16}$. This agrees with our previous result, which underpins the Comité international des poids et mesures recommended frequency value, and reduces the uncertainty by a factor of 3.6.

physics.atom-phCross-listedarXiv:2607.07044•Jul 9, 2026

Progress towards a laser-cooled cesium atomic fountain frequency standard at NIST, Gaithersburg

William M. Klipstein, Christopher R. Ekstrom, S. L. Rolston +1 more

We report here on progress towards the realization of an atomic frequency standard using a fountain of laser cooled cesium atoms. We have recently observed Ramsey fringes on the 9.2 GHz clock transition and have begun preliminary work aimed at characterizing our fountain. This paper describes briefly the apparatus, discusses our current work and near-term directions. We conclude with a brief discussion of a laser system being built to realize two-dimensional Raman cooling or Raman velocity selection for cooling below the single photon recoil limit. This system will be used either in our fountain or in a cold-atom clock to be flown on the International Space Station.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Nov 27, 2002•2 citations

Ticking near the Zero-Point Energy: Towards 1 x 10^-18 Accuracy in Al^+ Optical Clocks

Jwo-Sy Chen

The advancement of optical atomic clocks in the past two decades has motivated many potential applications in navigation, communication, and science. Accurate optical clocks that outperform the current cesium time standard also trigger a discussion about a possible redefinition of the SI second. The 27Al+ quantum logic clocks developed at the National Institute of Standards and Technology (NIST) were the first to achieve the clock fractional frequency uncertainty below 10-17 in 2010. To date, a few research groups around the world have demonstrated optical clocks based on various atomic transitions with fractional frequency uncertainty in the 10-18 range. The accuracy of the previous 27Al+ clocks was limited by the second order Doppler (time dilation) shift and the blackbody shift. Since 2010, the third 27Al+ optical clock is being developed at NIST to achieve a higher accuracy. The frequency uncertainties dominant in the previous clocks are controlled and reduced in the current optical clock. The new design of the ion trap system has reduced significantly both the blackbody radiation shift uncertainty and the time dilation shift uncertainty due to micromotion, while the time dilation shift uncertainty due to the secular motion has been reduced by more than an order of magnitude by operating the optical clock near the three dimensional zero-point energy. Despite those previously dominant uncertainties, several other systematic effects are being evaluated and some other efforts are being made to achieve a total uncertainty towards 1.0 x 10-18. In this thesis, I will document the detail of the construction and evaluation of the current 27Al+ optical clock developed at NIST.

•Jan 1, 2017•4 citations

Quantum projection noise limited stability and blackbody radiation shift uncertainty of NRC's Sr+atomic clock

Bin Jian, P. Dubé, Alan A. Madej

We present the current status of the Sr+optical atomic ion clock at the National Research Council of Canada including the study of the quantum projection noise (QPN) limited stability and the progress on the evaluation of the blackbody radiation (BBR) shift uncertainty. The latest QPN limited stability of NRC's Sr+ clock is 3 × 10-15at 1 sec averaging time. The fractional evaluated accuracy of the Sr+ ion clock has reached 1.2 × 10-17and is now dominated by the BBR shift uncertainty, the improved evaluation of which is currently in progress.

Conference on Precision Electromagnetic Measurements•Jul 1, 2016•0 citations
We present results from NIST-F1, the NIST primary frequency standard, a Cesium atomic fountain. In particular we give the results of the latest frequency evaluation which has a combined standard fractional frequency uncertainty of 1.3 × 10 -15 in the laboratory and a total uncertainty of 1.5 × 10 -15 including the time transfer to the Bureau International des Poids et Mesures (BIPM) international atomic time scale (TAI). We also present results that demonstrate the attainment of the quantum projection noise limit in this fountain.
We describe the operation of a laser cooled cesium fountain clock in the quantum limited regime. An ultrastable cryogenic sapphire oscillator is used to measure the short-term frequency stability of the fountain as a function of the number of detected atoms Nat{N}_{\mathrm{at}}Nat​. For Nat{N}_{\mathrm{at}}Nat​ varying from $4\ifmmode\times\else\texttimes\fi{}{10}^{4}$ to $6\ifmmode\times\else\texttimes\fi{}{10}^{5}$ the Allan standard deviation of the frequency fluctuations is in excellent agreement with the ${N}_{\mathrm{at}}^{\ensuremath{-}1/2}$ law of atomic projection noise. With $6\ifmmode\times\else\texttimes\fi{}{10}^{5}$ atoms, the relative frequency stability is $4\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}14}{\ensuremath{\tau}}^{\ensuremath{-}1/2}$, where \ensuremath{\tau} is the integration time in seconds. This is the best short-term stability ever reported for primary frequency standards, a factor of 5 improvement over previous results.
The accelerated development of laser methods for manipulating the internal state and motion of atoms, and the recent primary evaluation in France of a cesium frequency standard using cold atoms in an atomic fountain configuration, allow the frontiers of time metrology, accuracy, and stability to be pushed near parts in the 1016 level, a factor of 100 over the present primary laboratory clocks. These positive results revived the development of more accurate cesium atomic clocks, and the Institute of National Measurement Standards (INMS), of the National Research Council of Canada (NRC) is undertaking a cesium-fountain project aimed at reaching these new levels of accuracy and stability. This paper reviews its present status. To appreciate the considerable impact of cold atoms in time and frequency metrology, we begin by recalling the background principles of traditional cesium frequency standards, their typical performance and main limitations. After introducing the important theoretical results essential to understanding the techniques of laser cooling and magneto-optical trapping, we focus on describing the characterization and control of our magneto-optical trap (MOT) and report the parameters that allow us to fill the trap with a few million atoms in less than a second and cool them to a temperature lower than 5 muK using optical molasses. We will describe the specifics of our cesium-fountain prototype, which operates with a 2-dimensional moving molasses. This special configuration is applicable for multipulse operation of the fountain, which can greatly relax the local oscillator requirements for time keeping. Finally, progress toward our objective of launching cooled atoms, at a rate of one ensemble per second, at speeds of 7 m/s, for a fountain with an interrogation time of about 1 s, will be analysed.PACS Nos.: 06.20, 06.30, and 32.80P
Absolute frequency measurement of a 176^{176}176Lu+ (3D1)^+\,(^{3}\mathrm{D}_1)+(3D1​) standard against the NRC-FCs2 fountain with 2.6×10−162.6\times10^{-16}2.6×10−16 uncertainty
We report an improved absolute frequency measurement of the 176^{176}176Lu+ (3D1)^+\,(^{3}\mathrm{D}_1)+(3D1​) optical frequency standard, evaluated via a remote link to the NRC-FCs2 caesium fountain primary frequency standard. Operating a single ion clock with 94.2% uptime over 10 days, and using an ambiguity-resolved precise point positioning (PPP-AR) link over the Global Positioning System, we determine an absolute frequency of 353 638 794 073 800.332(91) 353\,638\,794\,073\,800.332(91)\,353638794073800.332(91)Hz at a fractional uncertainty of 2.6×10−162.6 \times 10^{-16}2.6×10−16. This agrees with our previous result, which underpins the Comité international des poids et mesures recommended frequency value, and reduces the uncertainty by a factor of 3.6.
We report here on progress towards the realization of an atomic frequency standard using a fountain of laser cooled cesium atoms. We have recently observed Ramsey fringes on the 9.2 GHz clock transition and have begun preliminary work aimed at characterizing our fountain. This paper describes briefly the apparatus, discusses our current work and near-term directions. We conclude with a brief discussion of a laser system being built to realize two-dimensional Raman cooling or Raman velocity selection for cooling below the single photon recoil limit. This system will be used either in our fountain or in a cold-atom clock to be flown on the International Space Station.
The advancement of optical atomic clocks in the past two decades has motivated many potential applications in navigation, communication, and science. Accurate optical clocks that outperform the current cesium time standard also trigger a discussion about a possible redefinition of the SI second. The 27Al+ quantum logic clocks developed at the National Institute of Standards and Technology (NIST) were the first to achieve the clock fractional frequency uncertainty below 10-17 in 2010. To date, a few research groups around the world have demonstrated optical clocks based on various atomic transitions with fractional frequency uncertainty in the 10-18 range. The accuracy of the previous 27Al+ clocks was limited by the second order Doppler (time dilation) shift and the blackbody shift. Since 2010, the third 27Al+ optical clock is being developed at NIST to achieve a higher accuracy. The frequency uncertainties dominant in the previous clocks are controlled and reduced in the current optical clock. The new design of the ion trap system has reduced significantly both the blackbody radiation shift uncertainty and the time dilation shift uncertainty due to micromotion, while the time dilation shift uncertainty due to the secular motion has been reduced by more than an order of magnitude by operating the optical clock near the three dimensional zero-point energy. Despite those previously dominant uncertainties, several other systematic effects are being evaluated and some other efforts are being made to achieve a total uncertainty towards 1.0 x 10-18. In this thesis, I will document the detail of the construction and evaluation of the current 27Al+ optical clock developed at NIST.
We present the current status of the Sr+optical atomic ion clock at the National Research Council of Canada including the study of the quantum projection noise (QPN) limited stability and the progress on the evaluation of the blackbody radiation (BBR) shift uncertainty. The latest QPN limited stability of NRC's Sr+ clock is 3 × 10-15at 1 sec averaging time. The fractional evaluated accuracy of the Sr+ ion clock has reached 1.2 × 10-17and is now dominated by the BBR shift uncertainty, the improved evaluation of which is currently in progress.