Applied Physics Letters

Quasiparticle heterodyne mixing in SIS tunnel junctions

P. L. Richards, T. M. Shen, R. Harris, Frances L. Lloyd

Published Mar 1, 1979• 163 citations
Publisher

Abstract

The rapid onset of quasiparitcle tunneling current in superconductor-insulator-superconductor (Josephson) junctions at voltages above 2Δ/e is being used for millimeter-wave heterodyne mixing. Junctions with a 2-μm diameter and RN=50 Ω have little capacitive shunting at the signal frequency of 36 GHz. Because there is no series resistance, residual capacitance can be tuned out. Double sideband conversion efficiencies of 0.32 and mixer noise temperatures as low as TM⩽7 K=4hν/k have been observed. The results are compared with shot-noise-limited mixer theory. Photon-assisted tunneling effects are seen which indicate the approach to photon-noise-limited operation.

DOI
10.1063/1.90782

Related papers

Predicted conversion gain in superconductor-insulator-superconductor quasiparticle mixers

John R. Tucker

A computer simulation is constructed to describe the performance of superconductor-insulator-superconductor (SIS) quasiparticle heterodyne receivers in terms of photon-assisted tunneling theory. The results predict that conversion efficiencies greater than unity can be realized at millimeter wave frequencies, with noise temperatures approaching the fundamental quantum limit. The nonlinearity responsible for the mixing is the extremely rapid onset of quasiparticle tunneling current in SIS junctions near the full gap voltage 2Δ/e, and is independent of the Josephson pair currents. Substantial gain is expected under a variety of conditions and for a wide range of source and load impedances.

Applied Physics Letters•Mar 15, 1980•107 citations

Conversion gain in mm-wave quasiparticle heterodyne mixers

T. M. Shen, P. L. Richards, R. Harris +1 more

We report the observation of heterodyne mixing in superconductor-insulator-superconductor tunnel junctions with significant conversion gain and with a noise temperature comparable to the photon noise limit. (Double sideband L−1=1.400.14, TM≲1.5 K at 36 GHz.) The mixing arises from the strong nonlinearity in the quasiparticle tunneling currents at voltages comparable to the full energy gap. Gain is observed when the onset of quasiparticle current is sufficiently sharp that quantum effects are important. The observed gain is in good quantitative agreement with calculations based on the work of Tucker. It should make possible the construction of photon-noise-limited microwave heterodyne receivers.

Applied Physics Letters•May 1, 1980•76 citations

Superconductive devices for millimeter wave detection, mixing, and amplification

P. L. Richards, Tek-Ming Shen

Single-particle (quasi-particle) tunneling through an insulating barrier between two superconductors or between a superconductor and a normal conductor is being used to make very-low-noise detectors and mixers for millimeter wavelengths. The nonlinearity of theI-Vcurve obtained from tunneling between two superconductors can be so strong that classical theory breaks down and photon-assisted tunneling theory must be used to understand device performance. Quantum theory predicts that a quasi-particle tunnel junction can be operated as a microwave photon detector with quantum efficiency close to unity or as a heterodyne mixer with conversion gain and with mixer noise temperature comparable with the quantum noise limitT_{M} =\bar{h}\omega/k. Both of these predictions have been experimentally realized at 36 GHz using superconductor-insulator-superconductor (SIS) junctions. It appears probable that these quasi-particle detectors and mixers will supercede the corresponding Josephson-effect devices at millimeter wavelengths.

IEEE Transactions on Electron Devices•Oct 1, 1980•61 citations

Quantum Limited Millimeter Wave Mixers and Detectors

P. L. Richards, T. M. Shen, R. Harris +1 more

We report operation of superconductor-insulator-superconductor quasiparticle tunnel junctions as mixers and detectors at millimeter wavelengths. The voltage scale of the nonlinearity in the I-V curve of such junctions can be small enough that classical device theory breaks down. Calculations based on photon assisted tunneling theory are then necessary to understand the observed performance. The performance predicted in this novel regime is sufficiently good that practical applications appear very promising. The best mixer result observed at 36 GHz is a double side-band mixer noise temperature Tm≤ 7 K which is about 4 times the photon noise limited value of hv/k. When operated as a direct detector, a current responsivity of 3,500 A/W was observed. This is half the quantum limited value e/hv, which corresponds to one tunneling electron for each incident microwave photon. The best observed NEP was 3 × 10-16W√Hz.

International Conference on Submillimeter Waves and Their Applications•Dec 1, 1979•0 citations

High-frequency limits of superconducting tunnel junction mixers

Dag Winkler, T. Claeson

We have investigated high-frequency limits of superconducting quasiparticle mixers from experiments on Al/Al-oxide-In/Al (or Ag) tunnel junctions, and from calculations based on Tucker’s quantum theory of mixing (QTM). The small superconducting energy gap of Al enabled us to study mixer performance at around the junction gap frequency, fg =(Δ1+Δ2)/h≊87 GHz, of superconductor-insulator-superconductor (SIS) mixers, and at twice the junction gap frequency for S-I-normal metal (SIN) mixers ( fg =Δ1/h) with available millimeter wave sources. Because of the low transition temperature of Al (Tc ≊1.3 K), a dilution refrigerator was used for providing temperatures below 1 K. The best mixer conversion efficiency was obtained for a low-resistance (∼34 Ω) six-junction array SIS mixer operated at f/fg ≊1 (in this case 73 GHz). The coupled single sideband conversion gain (with no image rejection) was −13.8 dB and the available conversion gain was estimated to −8.4 dB. Complicating nonequilibrium phenomena made it difficult to compare the performance of these relatively high-current-density mixers to the QTM. However, good agreement between calculated and corresponding measured conversion efficiencies and dynamic resistance values was obtained for the low-current-density mixers. Noise due to switching between rf-induced Josephson steps and interference from Josephson mixing could be quenched by a magnetic field. Several high-frequency limits are considered in this paper (such as Josephson switching noise, nonequilibrium phenomena, pair breaking, and energy gap limitations). Our results indicate that submillimeter wave SIS mixer receivers are likely to perform well, at least up to their gap frequencies, i.e., the THz region for large gap superconductors. Our QTM calculations showed that conversion gain larger than unity should be possible up to twice the gap frequency. Above this frequency the conversion loss will increase rapidly.

Journal of Applied Physics•Dec 1, 1987•35 citations

SIS mixers for low noise millimetre-wave heterodyne receivers

Steven R. Davies, C. T. Cunningham, Leslie T. Little

The development of ultra-low-noise receivers at frequencies of >200 GHz is primarily driven by astronomical applications. The most sensitive millimeter-wave receivers that have presently been constructed make use of the strong mixing afforded by superconductor-insulator-superconductor (SIS) tunnel junctions. In a collaborative project between UKC and RAL, a 230 GHz laboratory receiver has been built using a lead alloy SIS junction as the mixing element, mounted in 4:1 reduced-height waveguide, terminated at one end with a circular cross-section, adjustable backshort. Best results indicate a double-sideband receiver noise temperature of T/sub R/(DSB) approximately=120 K, which represents state-of-the-art performance at this frequency. Initial difficulties in achieving good mixing performance prompted an investigation into the importance of the 'quality' of mixer block backshort tuning elements. An analysis of the mixer equivalent circuit is presented which allows for loss in a non-ideal mixer block, and 3-port mixer model calculations are discussed which incorporate this analysis into the Tucker quantum theory of mixing.

•Mar 22, 1988•0 citations
The rapid onset of quasiparitcle tunneling current in superconductor-insulator-superconductor (Josephson) junctions at voltages above 2Δ/e is being used for millimeter-wave heterodyne mixing. Junctions with a 2-μm diameter and RN=50 Ω have little capacitive shunting at the signal frequency of 36 GHz. Because there is no series resistance, residual capacitance can be tuned out. Double sideband conversion efficiencies of 0.32 and mixer noise temperatures as low as TM⩽7 K=4hν/k have been observed. The results are compared with shot-noise-limited mixer theory. Photon-assisted tunneling effects are seen which indicate the approach to photon-noise-limited operation.
A computer simulation is constructed to describe the performance of superconductor-insulator-superconductor (SIS) quasiparticle heterodyne receivers in terms of photon-assisted tunneling theory. The results predict that conversion efficiencies greater than unity can be realized at millimeter wave frequencies, with noise temperatures approaching the fundamental quantum limit. The nonlinearity responsible for the mixing is the extremely rapid onset of quasiparticle tunneling current in SIS junctions near the full gap voltage 2Δ/e, and is independent of the Josephson pair currents. Substantial gain is expected under a variety of conditions and for a wide range of source and load impedances.
We report the observation of heterodyne mixing in superconductor-insulator-superconductor tunnel junctions with significant conversion gain and with a noise temperature comparable to the photon noise limit. (Double sideband L−1=1.400.14, TM≲1.5 K at 36 GHz.) The mixing arises from the strong nonlinearity in the quasiparticle tunneling currents at voltages comparable to the full energy gap. Gain is observed when the onset of quasiparticle current is sufficiently sharp that quantum effects are important. The observed gain is in good quantitative agreement with calculations based on the work of Tucker. It should make possible the construction of photon-noise-limited microwave heterodyne receivers.
Single-particle (quasi-particle) tunneling through an insulating barrier between two superconductors or between a superconductor and a normal conductor is being used to make very-low-noise detectors and mixers for millimeter wavelengths. The nonlinearity of theI-Vcurve obtained from tunneling between two superconductors can be so strong that classical theory breaks down and photon-assisted tunneling theory must be used to understand device performance. Quantum theory predicts that a quasi-particle tunnel junction can be operated as a microwave photon detector with quantum efficiency close to unity or as a heterodyne mixer with conversion gain and with mixer noise temperature comparable with the quantum noise limitT_{M} =\bar{h}\omega/k. Both of these predictions have been experimentally realized at 36 GHz using superconductor-insulator-superconductor (SIS) junctions. It appears probable that these quasi-particle detectors and mixers will supercede the corresponding Josephson-effect devices at millimeter wavelengths.
We report operation of superconductor-insulator-superconductor quasiparticle tunnel junctions as mixers and detectors at millimeter wavelengths. The voltage scale of the nonlinearity in the I-V curve of such junctions can be small enough that classical device theory breaks down. Calculations based on photon assisted tunneling theory are then necessary to understand the observed performance. The performance predicted in this novel regime is sufficiently good that practical applications appear very promising. The best mixer result observed at 36 GHz is a double side-band mixer noise temperature Tm≤ 7 K which is about 4 times the photon noise limited value of hv/k. When operated as a direct detector, a current responsivity of 3,500 A/W was observed. This is half the quantum limited value e/hv, which corresponds to one tunneling electron for each incident microwave photon. The best observed NEP was 3 × 10-16W√Hz.
We have investigated high-frequency limits of superconducting quasiparticle mixers from experiments on Al/Al-oxide-In/Al (or Ag) tunnel junctions, and from calculations based on Tucker’s quantum theory of mixing (QTM). The small superconducting energy gap of Al enabled us to study mixer performance at around the junction gap frequency, fg =(Δ1+Δ2)/h≊87 GHz, of superconductor-insulator-superconductor (SIS) mixers, and at twice the junction gap frequency for S-I-normal metal (SIN) mixers ( fg =Δ1/h) with available millimeter wave sources. Because of the low transition temperature of Al (Tc ≊1.3 K), a dilution refrigerator was used for providing temperatures below 1 K. The best mixer conversion efficiency was obtained for a low-resistance (∼34 Ω) six-junction array SIS mixer operated at f/fg ≊1 (in this case 73 GHz). The coupled single sideband conversion gain (with no image rejection) was −13.8 dB and the available conversion gain was estimated to −8.4 dB. Complicating nonequilibrium phenomena made it difficult to compare the performance of these relatively high-current-density mixers to the QTM. However, good agreement between calculated and corresponding measured conversion efficiencies and dynamic resistance values was obtained for the low-current-density mixers. Noise due to switching between rf-induced Josephson steps and interference from Josephson mixing could be quenched by a magnetic field. Several high-frequency limits are considered in this paper (such as Josephson switching noise, nonequilibrium phenomena, pair breaking, and energy gap limitations). Our results indicate that submillimeter wave SIS mixer receivers are likely to perform well, at least up to their gap frequencies, i.e., the THz region for large gap superconductors. Our QTM calculations showed that conversion gain larger than unity should be possible up to twice the gap frequency. Above this frequency the conversion loss will increase rapidly.
The development of ultra-low-noise receivers at frequencies of >200 GHz is primarily driven by astronomical applications. The most sensitive millimeter-wave receivers that have presently been constructed make use of the strong mixing afforded by superconductor-insulator-superconductor (SIS) tunnel junctions. In a collaborative project between UKC and RAL, a 230 GHz laboratory receiver has been built using a lead alloy SIS junction as the mixing element, mounted in 4:1 reduced-height waveguide, terminated at one end with a circular cross-section, adjustable backshort. Best results indicate a double-sideband receiver noise temperature of T/sub R/(DSB) approximately=120 K, which represents state-of-the-art performance at this frequency. Initial difficulties in achieving good mixing performance prompted an investigation into the importance of the 'quality' of mixer block backshort tuning elements. An analysis of the mixer equivalent circuit is presented which allows for loss in a non-ideal mixer block, and 3-port mixer model calculations are discussed which incorporate this analysis into the Tucker quantum theory of mixing.