A technique suitable for making automated high precision (1%) measurements of column densities Nl in vapor cells and ovens will be presented. The method employs a single-pass low finesse interferometer (e.g., a Mach-Zehnder), a broadband light source, and a 1024-element diode array in the image plane of a stigmatic spectrograph to measure photometrically the frequency-dependent intensity profiles of distorted interference fringes produced by the anomalous dispersion near an absorption line. Experimental measurements of Ba, Ca, and Li column densities show that Nl can be determined with high precision by numerically fitting a small segment (5–20 nm) of the spectrum to a simple analytic expression describing the intensity.
A technique suitable for making automated high precision (1%) measurements of column densities Nl in vapor cells and ovens will be presented. The method employs a single-pass low finesse interferometer (e.g., a Mach-Zehnder), a broadband light source, and a 1024-element diode array in the image plane of a stigmatic spectrograph to measure photometrically the frequency-dependent intensity profiles of distorted interference fringes produced by the anomalous dispersion near an absorption line. Experimental measurements of Ba, Ca, and Li column densities show that Nl can be determined with high precision by numerically fitting a small segment (5–20 nm) of the spectrum to a simple analytic expression describing the intensity.
A quick and simple technique for determining line of sight number densities in atomic vapor ovens will be presented. The technique is based on measuring the frequency-dependent distortion of interference fringe profiles which is produced when an absorbing vapor is placed in one arm of a Mach-Zehnder interferometer. In contrast to previous interferometric methods, in which only the peak intensity positions of the fringes are measured, this method relies on measuring the entire intensity profiles of the fringes. This is made possible by placing a 1024-channel diode array detector at the exit plane of a spectrograph. The density is then determined with a precision of 1 % or better by fitting the experimental data to a simple analytic expression.
III-8.Comparison of optical pumping signals for two spherical cells with different buffer gas pressures as a function of density times diameter of cell for equal D2/D1.60 IV-1.Energy level diagram showing hyperfine structure of Rb Di line.Units are 10*3 cm-1.67 IV-2.Equivalent circuit for rate equations involving ex change polarization.73 IV-3.Diagram of optical system for optical pumping of Rb. 83 IV-4.Block diagram of Rb optical pumping signal detection system.85 IV-5.Block diagram of Rb light detection system.90 IV-6.Typical photograph from which relaxation time measure ments are made..Time increases from left to right.Scale is 1 millisecond per division.92 IV-7.Lines determined from measurements on time dependence of Rb87 signals at 50°C for the two different light in tensities.Scatter of points is too small to be notice able on graph.93 A-1.Spectral profile of D1 radiation from a Varian spectral lamp containing natural Rb.Ill A-2.Spectral profile of Di radiation from a Varian spectral lamp containing Rb87.112 A-3-Spectral profile of Di radiation from a Varian spectral lamp containing Rb87 after filtering by an Rb85 absorption cell.113 vi CHAPTER I2 atomic ground states and the parameters of various relaxation processes of gaseous systems.These investigations led to the development of mag netometers of unique sensitivity.More recently, very precise frequency standards have been developed using the methods of optical pumping and the knowledge gained through their application.The present work was undertaken in the context of extending our knowledge of the dynamics of optical pumping methods and of exploiting these methods for the deter mination of an interesting atomic exchange cross section.Optical pumping may be considered as a specialized technique used in conjunction with magnetic resonance phenomena.All magnetic reso nance techniques depend upon obtaining an oriented (polarized) macro scopic sample of matter, that is, matter with a net magnetic moment.In the atomic beam magnetic resonance method, this is accomplished by sort ing out, spatially, atoms whose magnetic moments have a particular ori entation with respect to a magnetic field.In nuclear or electron para magnetic resonance work in solids, liquids, or gases, the small thermal equilibrium polarization that matter possesses in a magnetic field is exploited.Optical pumping enhances this equilibrium polarization through selective optical absorption, by a gaseous atomic system, of polarized resonance radiation.Optical pumping offers the great advan tage of experimental simplicity, as compared to other magnetic resonance techniques, but suffers from severe limitations in application.Since the original suggestion by Brossel and Nastier^ and subse quent development by many others, optical pumping, in conjunction with the transmission monitoring technique of signal detection, has became a standard technique in the study of alkali metal ground states.By far the greatest amount of work in optical pumping has been concerned with alkali metal vapors.Bell, Bloom/ and others^ have considered the process of the optical pumping of the alkalis with attention to the spec tral composition of the pumping light, that is, the resonance radiation incident on the alkali vapor.Colegrove and Franken? have recently dis cussed the complication in the analyses of optical pumping signals for Q helium when the helium absorption cell is optically thick.Hobart has considered this same complication for sodium.Prediction of signals must take into account the fact that the pumping light is absorbed ap proximately exponentially in the optical pumping absorption cell.This means that the absorption coefficient, which is proportional to the al kali density, times the length of the cell is a significant parameter in determining the strength of the signal.Similar calculations of the dependence of optical pumping signals on alkali density and spectral com position of the pumping light will be presented in this work.In order to test the signal predictions> a high resolution Fabry-Perot spectrometer was constructed.This instrument can be used for two purposes : the investigation of the intensity distribution of the pumping light, and, more importantly, determinations of the alkali vapor density in the absorption cell.The desired data are curves of optical pumping signals, for a typical sodium optical pumping experiment, as a function of density.It is often necessary to know these densities in order to is limited to the accuracy to which the density is known.Since the Fabry-Perot spectrometer used to measure sodium vapor densities in conjunction with the signal strength versus density meas urements can be applied to different systems, it was decided to make a determination of the rubidium 85-rubidium 87 spin exchange cross sec tion.The reasons for this choice are discussed in detail in Chapt.IV.In brief, work on rubidium exchange offered some experimental sim plifications and rubidium has previously been studied more thoroughly than other systems.
We have calculated the line profiles to be expected when a Fabry–Perot interferometer is used to measure absorption lines. We have shown that large errors may be introduced in the measurement of the integrated absorption, even when an interferometer of high finesse is used. Curves and tables are given for finding the true absorption width and the true peak absorption from the apparent values observed under different operating conditions of the emission light source and the interferometer. We show qualitatively that the distortions are partially due to the presence of nonzero wings in the instrument-bandpass function. Finally, we show a Fourier series expansion of the integral giving the transmittance of the Fabry-Perot interferometer when absorbing atoms are in the light path.
The sensitivity of the resonance-fluorescence method for the measurement of very-low sodium-vapor densities (<1010 atoms/cm3) has been studied. Light from a sodium spectral lamp is sent through a sodium-containing vessel, whose temperature can be varied. The vapor density has been measured in the region of 47–146 °C. At 47 °C, the vapor density is about 107 atoms/cm3. The measurements were performed with both a photon-counting device and a lock-in amplifier. The experimental results have been normalized to absolute density data given in the literature. Fitting our points to the equation logN = a + b/T yields the values a = 23.715 and b = −5257.7 K.
We review our recent experimental progress in quantum technology employing amplification effect of four-wave mixing in a rubidium vapor. We have produced an intensity difference squeezed light source at frequencies as low as 1.5 kHz which is so far the lowest frequency at which squeezing has been observed in an atomic system. Moreover, we find that the bandwidth of our squeezed light source can be controlled with light intensity pumping. Using our non-classical light source, we have further developed a nonlinear Mach-Zehnder (MZ) interferometer, for which the maximum fringe intensity depends quadratically on the intensity of the phase-sensing field at the high-gain regime, leading to much better sensitivity than a linear MZ interferometer in which the beam splitters have the same phase-sensing intensity. The quantum technologies developed by our group could have great potential in areas such as precision measurement and quantum information.
Dott. Alessandra Rocco Negative dispersion without absorption in atomic ensembles In this work the optical properties of a calcium atomic beam, strongly driven on the transition, are investigated, in order to obtain a coherently prepared medium with the right amount of negative dispersion at a point of zero absorption. From the theory it is well known that a strongly driven Two-Level system exhibits such properties. Such a medium could in particular be used to fill an optical resonator in order to obtain a broadband high finesse cavity (White Light Cavity). For the investigations a spectroscopic method had been used, consisting of a Mach-Zehnder interferometer with a phase modulated arm. In this way it is possible to perform a high sensitive simultaneous measurement of both phase shift and absorption profiles in a calcium atomic beam, for an increasing driving field, which frequency is stabilized on the transition 4s2 S0 4s4p P1 at 423nm. For the first time both absorption and phase shift were systematic investigated as function of the driving field intensity, while it was developed a new geometrical configuration for the atomic oven which permitted to reach a higher particle density in the interaction zone. It was then possible to calculate the values of derivative of phase shift and absorption at the transition frequency, where the dispersion results anomalous, having fitted the measured curves to the phase shift and absorption profiles for a strongly driven Two-Level Atom. An analysis of the evolution of the both the quantities as driving field function could be then performed. The theoretical analysis of the strongly driven two level system could then be experimentally verified, especially that the absorption decreases stronger than dispersion with an increasing driving field. It was in fact measured a decreasing of a factor 53 in the dispersion, between the not driven and driven atomic system while the corresponding absorption decreased of a factor 330, for a value of the driving field of D 2π54.4MHz. The possibility of inserting the medium inside an optical resonator to obtain a broadband high finesse cavity has also been discussed. The data analysis showed that even if the λ compensation was reachable in the achieved condition, the residual absorption was still too high to realize a White Light Cavity. The configuration for further development of the system which should allow this realization was also analyzed, together with a comparison with the performances of different atomic systems.