Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review Letters

Realization of a two-photon maser oscillator

M. Brune, J. M. Raimond, P. Goy, L. Davidovich, S. Haroche

Published Oct 26, 1987• 560 citations
Publisher

Abstract

We have built the first quantum oscillator working on two-photon stimulated emission of radiation. It oscillates continuously on a degenerate two-photon transition between the levels 40S and 39S of rubidium atoms. The oscillation is sustained in a Q\ensuremath{\simeq}${10}^{8}$ niobium superconducting cavity at 68.415 87 GHz. At threshold, this new maser system operates with only a few atoms and a few tens of photons at a time in the cavity.

DOI
10.1103/physrevlett.59.1899

Related papers

Theory of the Rydberg-atom two-photon micromaser

M. Brune, J. M. Raimond, S. Haroche

A continuous-wave maser operating on a two-photon transition between Rydberg levels is expected to oscillate with about one atom and a few tens of microwave photons at any time in its superconducting cavity. We analyze in detail the characteristics of this new microscopic quantum electronics device presently under construction in our laboratory.

Physical Review A•Jan 1, 1987•241 citations

The two-photon Rydberg atom micromaser

M. Brune, J. M. Raimond, P. Goy +2 more

A Rydberg atom maser operated on a two-photon degenerate atomic transition is discussed. This device combines two interesting features: it is a quantum oscillator working on an intrinsically nonlinear effect and it is a micromaser, with only a few atoms and a few tens of photons at a time in the cavity. The reasons why Rydberg atom-superconducting cavity systems are well adapted for two-photon maser studies are discussed, and the main properties of the device are analyzed by comparing it to Rydberg masers operating on one-photon transitions.>

IEEE Journal of Quantum Electronics•Jul 1, 1988•31 citations

Quantum theory of a two-photon micromaser

L. Davidovich, J. M. Raimond, M. Brune +1 more

We present the quantum theory of a microscopic maser operating on a degenerate two-photon transition between levels of the same parity. We derive both a master equation and a Fokker-Planck equation for this system, and show that quantum effects may have a substantial influence on the behavior of the maser. They modify the oscillation threshold and make external triggering of this maser unnecessary, whereas, according to semiclassical theory, such a triggering is required to start up the maser oscillation. We derive the phase-diffusion properties of the field and show that the diffusion coefficient is complex in this case, its imaginary part being associated with a frequency shift of the field inside the cavity. We show that, in steady state, the photon-number statistics is sub-Poissonian for a wide range of pumping rates.

Physical Review A•Oct 1, 1987•202 citations

THE ONE-ATOM MASER AND THE GENERATION OF NONCLASSICAL LIGHT

HERBERT WALTHER

The work on the one-atom-maser is reviewed. The superconducting maser cavity made of niobium and cooled to 0.5 K to exclude thermal photons has a quality factor of 3×10 10 . Velocity-selected Rydberg atoms pump the maser. The field inside the cavity is investigated by probing the atoms leaving the cavity. The dynamics of the Rabi nutation was investigated. Furthermore the statistics of the photons in the cavity was determined to be sub-Poissionian corresponding to photon-number fluctuations of 70% below the vacuum-state limit. The one-atom maser is the only maser system which leads to nonclassical radiation even when pumping processes with Poissonian statistics are used.

Foundations of Quantum Mechanics•Apr 1, 1992•0 citations

From micromasers to microlasers

HERBERT WALTHER

The one-atom maser or micromaser is, in contrary to ordinary masers and lasers, a pure quantum device operating with only a few photons and less than one pump atom on the average in the maser cavity. It is thus an ideal device to study quantum phenomena such as the generation of nonclassical light. The cavity is a superconducting niobium microwave resonator with a high quality factor (up to 3 × 1010). Using a single trapped ion related experiments can now also be performed in the infrared spectral region.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jan 1, 1994•0 citations

Single-atom experiments and the test of fundamental quantum physics

HERBERT WALTHER

The work on the one-atom maser is reviewed. The superconducting maser cavity made of niobium and cooled to 0.5 K to exclude thermal photons has a quality factor of 3 X 1010. Velocity-selected Rydberg atoms pump the maser. The field inside the cavity is investigated by probing the atoms leaving the cavity. The dynamics of the Rabi nutation were investigated. Furthermore, the statistics of the photons in the cavity were determined to be sub-Poissonian corresponding to photon-number fluctuations of 70% below the vacuum-state limit. The one-atom maser is the only maser system which leads to nonclassical radiation even when pumping processes with Poissonian statistics are used. Some applications of the one- atom maser to study the quantum measurement process also are discussed.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Oct 28, 1992•0 citations
We have built the first quantum oscillator working on two-photon stimulated emission of radiation. It oscillates continuously on a degenerate two-photon transition between the levels 40S and 39S of rubidium atoms. The oscillation is sustained in a Q\ensuremath{\simeq}108{10}^{8}108 niobium superconducting cavity at 68.415 87 GHz. At threshold, this new maser system operates with only a few atoms and a few tens of photons at a time in the cavity.
A Rydberg atom maser operated on a two-photon degenerate atomic transition is discussed. This device combines two interesting features: it is a quantum oscillator working on an intrinsically nonlinear effect and it is a micromaser, with only a few atoms and a few tens of photons at a time in the cavity. The reasons why Rydberg atom-superconducting cavity systems are well adapted for two-photon maser studies are discussed, and the main properties of the device are analyzed by comparing it to Rydberg masers operating on one-photon transitions.>
We present the quantum theory of a microscopic maser operating on a degenerate two-photon transition between levels of the same parity. We derive both a master equation and a Fokker-Planck equation for this system, and show that quantum effects may have a substantial influence on the behavior of the maser. They modify the oscillation threshold and make external triggering of this maser unnecessary, whereas, according to semiclassical theory, such a triggering is required to start up the maser oscillation. We derive the phase-diffusion properties of the field and show that the diffusion coefficient is complex in this case, its imaginary part being associated with a frequency shift of the field inside the cavity. We show that, in steady state, the photon-number statistics is sub-Poissonian for a wide range of pumping rates.
The work on the one-atom-maser is reviewed. The superconducting maser cavity made of niobium and cooled to 0.5 K to exclude thermal photons has a quality factor of 3×10 10 . Velocity-selected Rydberg atoms pump the maser. The field inside the cavity is investigated by probing the atoms leaving the cavity. The dynamics of the Rabi nutation was investigated. Furthermore the statistics of the photons in the cavity was determined to be sub-Poissionian corresponding to photon-number fluctuations of 70% below the vacuum-state limit. The one-atom maser is the only maser system which leads to nonclassical radiation even when pumping processes with Poissonian statistics are used.
The one-atom maser or micromaser is, in contrary to ordinary masers and lasers, a pure quantum device operating with only a few photons and less than one pump atom on the average in the maser cavity. It is thus an ideal device to study quantum phenomena such as the generation of nonclassical light. The cavity is a superconducting niobium microwave resonator with a high quality factor (up to 3 × 1010). Using a single trapped ion related experiments can now also be performed in the infrared spectral region.
The work on the one-atom maser is reviewed. The superconducting maser cavity made of niobium and cooled to 0.5 K to exclude thermal photons has a quality factor of 3 X 1010. Velocity-selected Rydberg atoms pump the maser. The field inside the cavity is investigated by probing the atoms leaving the cavity. The dynamics of the Rabi nutation were investigated. Furthermore, the statistics of the photons in the cavity were determined to be sub-Poissonian corresponding to photon-number fluctuations of 70% below the vacuum-state limit. The one-atom maser is the only maser system which leads to nonclassical radiation even when pumping processes with Poissonian statistics are used. Some applications of the one- atom maser to study the quantum measurement process also are discussed.