Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE Journal of Quantum Electronics

The two-photon Rydberg atom micromaser

M. Brune, J. M. Raimond, P. Goy, L. Davidovich, S. Haroche

Published Jul 1, 1988• 31 citations
Publisher

Abstract

A Rydberg atom maser operated on a two-photon degenerate atomic transition is discussed. This device combines two interesting features: it is a quantum oscillator working on an intrinsically nonlinear effect and it is a micromaser, with only a few atoms and a few tens of photons at a time in the cavity. The reasons why Rydberg atom-superconducting cavity systems are well adapted for two-photon maser studies are discussed, and the main properties of the device are analyzed by comparing it to Rydberg masers operating on one-photon transitions.>

DOI
10.1109/3.970

Related papers

Theory of the Rydberg-atom two-photon micromaser

M. Brune, J. M. Raimond, S. Haroche

A continuous-wave maser operating on a two-photon transition between Rydberg levels is expected to oscillate with about one atom and a few tens of microwave photons at any time in its superconducting cavity. We analyze in detail the characteristics of this new microscopic quantum electronics device presently under construction in our laboratory.

Physical Review A•Jan 1, 1987•241 citations

Realization of a two-photon maser oscillator

M. Brune, J. M. Raimond, P. Goy +2 more

We have built the first quantum oscillator working on two-photon stimulated emission of radiation. It oscillates continuously on a degenerate two-photon transition between the levels 40S and 39S of rubidium atoms. The oscillation is sustained in a Q\ensuremath{\simeq}${10}^{8}$ niobium superconducting cavity at 68.415 87 GHz. At threshold, this new maser system operates with only a few atoms and a few tens of photons at a time in the cavity.

Physical Review Letters•Oct 26, 1987•560 citations

From micromasers to microlasers

HERBERT WALTHER

The one-atom maser or micromaser is, in contrary to ordinary masers and lasers, a pure quantum device operating with only a few photons and less than one pump atom on the average in the maser cavity. It is thus an ideal device to study quantum phenomena such as the generation of nonclassical light. The cavity is a superconducting niobium microwave resonator with a high quality factor (up to 3 × 1010). Using a single trapped ion related experiments can now also be performed in the infrared spectral region.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jan 1, 1994•0 citations

Experiments with the One-atom-maser

Linas Urbonas

There are only fistful of systems in physics that can be described by an exact theory from first principles and, at the same time, can be investigated under experimental conditions approaching the idealized theoretical ones. The one-atom-maser or micromaser provides such an example, making a detailed study of the fundamental properties of the atom-field interaction possible. The situation realized in a micromaser is very close to the ideal case of a single two-level atom interacting with a single quantized mode of a cavity field. In the micromaser the atoms have a dual purpose of both pumping the field and also probing it via measurements of the outgoing atoms. Any other means of measuring the field inside the resonator has the detrimental effect of lowering its Q-factor and thereby the photon storage time. The long photon storage time of the resonator allows for the decay of the field to be negligible during the passage of an atom and its interaction with the field. The behavior of atoms in a cavity is governed by the oscillatory exchange of energy between the atoms and the field, which is called Rabi oscillation. For cavity fields in the vacuum and few photon number states (Fock states), Rabi oscillations have been measured in the past. To prevent thermal effects from polluting the pure number states these experiments were performed at low temperatures (below 1 K). However, the observed resolution of the Rabi oscillations measurements was quite disappointing (only about 2% of the predicted theoretical value) and precluded more ambitious experiments like atom-atom correlations or time resolved investigations of the maser field dynamics. The observed contrast of Rabi oscillations can be considered as a figure of merit for the experimental resolution of quantum features of a maser field. Therefore, a high resolution in the measurements of Rabi oscillations is crucial. This thesis describes the methods and improvements applied to enhance the resolution of Rabi oscillations by a factor of 8. The following upgrades and developments proved to be crucial in this work: 1) The base temperature of the cryogenic system was lowered to 0.3 K, i.e. one third of the original value. At the same time, the time during which the system remains at the base temperature was improved by almost of an order of magnitude (to more than 12 h). 2) For the promotion of the atoms to the Rydberg regime new three-step diode laser setup was constructed. The excitation efficiency compared to the old dye laser was increased by two orders. Using top-of-fringe stabilization with new spectroscopic methods, specially designed error detection and feedback schemes as well as state-of-the-art PID regulators the continuous locking of lasers is about 8 h (compared to about 20 min with the old dye laser system). 3) The flexibility of using the three step excitation allows to excite different maser states and for the first time to investigate pure maser transition. 4) Various improvements on the atomic oven and the channeltron detection unit led to the reliable and stable production and detection of the atomic beam. Observed distribution of the atomic beam statistics reaches to within 6% the Poisson limit which is expected in the absence of experimental imperfections. 5) New developed techniques in magnetic field compensation allow to perform such measurements with two orders of magnitude better accuracy compared to the previous experiments. To demonstrate the new capabilities of the apparatus and to apply its improved resolution of quantum fields we performed a previously impossible in-depth analysis of mean photon number and the atomic inversion produced by a micromaser for various detunings between the cavity- and atomic resonance frequency.

•Jan 1, 2009•0 citations

Quantum theory of a two-photon micromaser

L. Davidovich, J. M. Raimond, M. Brune +1 more

We present the quantum theory of a microscopic maser operating on a degenerate two-photon transition between levels of the same parity. We derive both a master equation and a Fokker-Planck equation for this system, and show that quantum effects may have a substantial influence on the behavior of the maser. They modify the oscillation threshold and make external triggering of this maser unnecessary, whereas, according to semiclassical theory, such a triggering is required to start up the maser oscillation. We derive the phase-diffusion properties of the field and show that the diffusion coefficient is complex in this case, its imaginary part being associated with a frequency shift of the field inside the cavity. We show that, in steady state, the photon-number statistics is sub-Poissonian for a wide range of pumping rates.

Physical Review A•Oct 1, 1987•202 citations

Construction, Theory and simulation of Cavity QED Systems

Mark S. Everitt

The microscopically pumped maser, or micromaser is a cavity QED experiment intended to be a physical realisation of the Jaynes-Cummings model of a single two-level atom interacting with a single mode electromagnetic field. This is the simplest model that describes the interaction between light and matter, yet it predicts behaviour unexpected from semiclassical models, such as the revival of Rabi oscillations of an atom interacting with an initially coherent field and non-monotonic linewidth as a function of pumping. The micromaser at the University of Leeds consists of a high quality superconducting microwave cavity designed to be resonant with the transition between two specific Rydberg states of rubidium. These two states behave like an ideal two level atom, and couple strongly to the cavity field due to a large dipole moment. These Rydberg atoms are passed through the cavity in a rarified beam such that in most instances when there is an atom in the cavity, there will only be one, closely approximating the Jaynes-Cummings model. I present experimental work on the build phase of the micromaser. Specifically I routed all of the wiring and microwave lines in the cryostat that contains the micromaser, and designed mounts for various components. I also designed several testing methods for probing high quality microwave cavity resonances and quality factors which are presented. Using the Jaynes-Cummings model as a prototype, I demonstrate how extensions to the model can be used to construct universal quantum logic gates that operate on photonic qubits in a multi-mode cavity. This could be realised in a micromaser with a multi-mode cavity. Conversely, I demonstrate that by using atoms as qubits, detuned cavities can be used to generate entangled resources such as the Greenberger-Horne-Zeilinger state, the W state, and graph states of atoms. I show that single qubit rotations on Rydberg atom qubits have already been experimentally demonstrated so that in combination these entangled resources are useful for quantum metrology, quantum computation and even tests of quantum gravity.

•Sep 1, 2009•0 citations
A Rydberg atom maser operated on a two-photon degenerate atomic transition is discussed. This device combines two interesting features: it is a quantum oscillator working on an intrinsically nonlinear effect and it is a micromaser, with only a few atoms and a few tens of photons at a time in the cavity. The reasons why Rydberg atom-superconducting cavity systems are well adapted for two-photon maser studies are discussed, and the main properties of the device are analyzed by comparing it to Rydberg masers operating on one-photon transitions.>
We have built the first quantum oscillator working on two-photon stimulated emission of radiation. It oscillates continuously on a degenerate two-photon transition between the levels 40S and 39S of rubidium atoms. The oscillation is sustained in a Q\ensuremath{\simeq}108{10}^{8}108 niobium superconducting cavity at 68.415 87 GHz. At threshold, this new maser system operates with only a few atoms and a few tens of photons at a time in the cavity.
The one-atom maser or micromaser is, in contrary to ordinary masers and lasers, a pure quantum device operating with only a few photons and less than one pump atom on the average in the maser cavity. It is thus an ideal device to study quantum phenomena such as the generation of nonclassical light. The cavity is a superconducting niobium microwave resonator with a high quality factor (up to 3 × 1010). Using a single trapped ion related experiments can now also be performed in the infrared spectral region.
There are only fistful of systems in physics that can be described by an exact theory from first principles and, at the same time, can be investigated under experimental conditions approaching the idealized theoretical ones. The one-atom-maser or micromaser provides such an example, making a detailed study of the fundamental properties of the atom-field interaction possible. The situation realized in a micromaser is very close to the ideal case of a single two-level atom interacting with a single quantized mode of a cavity field. In the micromaser the atoms have a dual purpose of both pumping the field and also probing it via measurements of the outgoing atoms. Any other means of measuring the field inside the resonator has the detrimental effect of lowering its Q-factor and thereby the photon storage time. The long photon storage time of the resonator allows for the decay of the field to be negligible during the passage of an atom and its interaction with the field. The behavior of atoms in a cavity is governed by the oscillatory exchange of energy between the atoms and the field, which is called Rabi oscillation. For cavity fields in the vacuum and few photon number states (Fock states), Rabi oscillations have been measured in the past. To prevent thermal effects from polluting the pure number states these experiments were performed at low temperatures (below 1 K). However, the observed resolution of the Rabi oscillations measurements was quite disappointing (only about 2% of the predicted theoretical value) and precluded more ambitious experiments like atom-atom correlations or time resolved investigations of the maser field dynamics. The observed contrast of Rabi oscillations can be considered as a figure of merit for the experimental resolution of quantum features of a maser field. Therefore, a high resolution in the measurements of Rabi oscillations is crucial. This thesis describes the methods and improvements applied to enhance the resolution of Rabi oscillations by a factor of 8. The following upgrades and developments proved to be crucial in this work: 1) The base temperature of the cryogenic system was lowered to 0.3 K, i.e. one third of the original value. At the same time, the time during which the system remains at the base temperature was improved by almost of an order of magnitude (to more than 12 h). 2) For the promotion of the atoms to the Rydberg regime new three-step diode laser setup was constructed. The excitation efficiency compared to the old dye laser was increased by two orders. Using top-of-fringe stabilization with new spectroscopic methods, specially designed error detection and feedback schemes as well as state-of-the-art PID regulators the continuous locking of lasers is about 8 h (compared to about 20 min with the old dye laser system). 3) The flexibility of using the three step excitation allows to excite different maser states and for the first time to investigate pure maser transition. 4) Various improvements on the atomic oven and the channeltron detection unit led to the reliable and stable production and detection of the atomic beam. Observed distribution of the atomic beam statistics reaches to within 6% the Poisson limit which is expected in the absence of experimental imperfections. 5) New developed techniques in magnetic field compensation allow to perform such measurements with two orders of magnitude better accuracy compared to the previous experiments. To demonstrate the new capabilities of the apparatus and to apply its improved resolution of quantum fields we performed a previously impossible in-depth analysis of mean photon number and the atomic inversion produced by a micromaser for various detunings between the cavity- and atomic resonance frequency.
We present the quantum theory of a microscopic maser operating on a degenerate two-photon transition between levels of the same parity. We derive both a master equation and a Fokker-Planck equation for this system, and show that quantum effects may have a substantial influence on the behavior of the maser. They modify the oscillation threshold and make external triggering of this maser unnecessary, whereas, according to semiclassical theory, such a triggering is required to start up the maser oscillation. We derive the phase-diffusion properties of the field and show that the diffusion coefficient is complex in this case, its imaginary part being associated with a frequency shift of the field inside the cavity. We show that, in steady state, the photon-number statistics is sub-Poissonian for a wide range of pumping rates.
The microscopically pumped maser, or micromaser is a cavity QED experiment intended to be a physical realisation of the Jaynes-Cummings model of a single two-level atom interacting with a single mode electromagnetic field. This is the simplest model that describes the interaction between light and matter, yet it predicts behaviour unexpected from semiclassical models, such as the revival of Rabi oscillations of an atom interacting with an initially coherent field and non-monotonic linewidth as a function of pumping. The micromaser at the University of Leeds consists of a high quality superconducting microwave cavity designed to be resonant with the transition between two specific Rydberg states of rubidium. These two states behave like an ideal two level atom, and couple strongly to the cavity field due to a large dipole moment. These Rydberg atoms are passed through the cavity in a rarified beam such that in most instances when there is an atom in the cavity, there will only be one, closely approximating the Jaynes-Cummings model. I present experimental work on the build phase of the micromaser. Specifically I routed all of the wiring and microwave lines in the cryostat that contains the micromaser, and designed mounts for various components. I also designed several testing methods for probing high quality microwave cavity resonances and quality factors which are presented. Using the Jaynes-Cummings model as a prototype, I demonstrate how extensions to the model can be used to construct universal quantum logic gates that operate on photonic qubits in a multi-mode cavity. This could be realised in a micromaser with a multi-mode cavity. Conversely, I demonstrate that by using atoms as qubits, detuned cavities can be used to generate entangled resources such as the Greenberger-Horne-Zeilinger state, the W state, and graph states of atoms. I show that single qubit rotations on Rydberg atom qubits have already been experimentally demonstrated so that in combination these entangled resources are useful for quantum metrology, quantum computation and even tests of quantum gravity.