Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics A

Planar microwave biased RF-SQUIDs in niobium technology

M. M�ck, Christoph Heiden

Published Jun 1, 1992• 13 citations
Publisher
DOI
10.1007/bf00324323

Related papers

Planar Microwave Biased rf-SQUIDs with a Cryogenic HEMT amplifier

R. Mezzena, Stefano Vitale

•Jan 1, 1992•0 citations

Planar microwave rf SQUID gradiometer

Michael Mück, D. Diehl, Christoph Heiden

Cryogenics•Dec 1, 1990•7 citations

New planar SQUIDs based on niobium technology

Michael Mück, Christoph Heiden

Two new SQUID variants have been made and tested using nanobridges as Josephson contacts. The first is a dc SQUID whose hysteretic weak links are inductively shunted such that it operates as a relaxation oscillator with a frequency depending on the applied magnetic flux. When standard ICs are used for FM detection, the readout electronics are cheap and compact, of the size of a matchbox. The second variant is a microwave-biased rf SQUID incorporated into a λ/2 stripline resonator, which is capacitively coupled to a coaxial cable leading to the room-temperature electronics. Peak-to-peak modulation voltages of several hundred μV were obtained in the investigated frequency range of 3 to 4.2 GHz. For both SQUID variants, white flux noise values of some 10−5Φ0/Hz1/2 have been found.

Soviet Journal of Low Temperature Physics•May 1, 1990•0 citations

Planar microwave biased radio frequency SQUIDs with a cryogenic preamplifier

Michael Mück, G. Hallmanns, Christoph Heiden +4 more

We report on the design and performance of a planar microwave rf-SQUID readout by a cryogenic preamplifier. The SQUID-sensor consists of a planar half-wavelength microstrip resonator, into which the SQUID-loop is integrated. The pump frequency is 1.7 GHz. The cryogenic preamplifier employs a microwave high electron mobility transistor (HEMT), located close to the SQUID sensor. Measurements of the flux noise and the fractional step rise parameter were carried out in the temperature range between 4.2 and 1.5 K. In an open loop white flux noise values of 2×10−6 Φ0/√Hz were obtained at 4.2 K.

Applied Physics Letters•Sep 7, 1992•6 citations

Rf-biased SQUID with half-wavelength transmission line

Thomas W. Bradshaw, William P. Pratt

Cryogenics•Sep 1, 1979•2 citations

Construction and Performance of Wire-Junction RF-SQUIDs

A. C. Bruno, James Edward Zimmerman

Springer proceedings in physics•Jan 1, 1992•7 citations
Two new SQUID variants have been made and tested using nanobridges as Josephson contacts. The first is a dc SQUID whose hysteretic weak links are inductively shunted such that it operates as a relaxation oscillator with a frequency depending on the applied magnetic flux. When standard ICs are used for FM detection, the readout electronics are cheap and compact, of the size of a matchbox. The second variant is a microwave-biased rf SQUID incorporated into a λ/2 stripline resonator, which is capacitively coupled to a coaxial cable leading to the room-temperature electronics. Peak-to-peak modulation voltages of several hundred μV were obtained in the investigated frequency range of 3 to 4.2 GHz. For both SQUID variants, white flux noise values of some 10−5Φ0/Hz1/2 have been found.
We report on the design and performance of a planar microwave rf-SQUID readout by a cryogenic preamplifier. The SQUID-sensor consists of a planar half-wavelength microstrip resonator, into which the SQUID-loop is integrated. The pump frequency is 1.7 GHz. The cryogenic preamplifier employs a microwave high electron mobility transistor (HEMT), located close to the SQUID sensor. Measurements of the flux noise and the fractional step rise parameter were carried out in the temperature range between 4.2 and 1.5 K. In an open loop white flux noise values of 2×10−6 Φ0/√Hz were obtained at 4.2 K.