Applied Physics Letters

Planar microwave biased radio frequency SQUIDs with a cryogenic preamplifier

Michael Mück, G. Hallmanns, Christoph Heiden, Giorgio Fontana, MASSIMO CERDONIO, R. Mezzena, Stefano Vitale

Published Sep 7, 1992• 6 citations
Publisher

Abstract

We report on the design and performance of a planar microwave rf-SQUID readout by a cryogenic preamplifier. The SQUID-sensor consists of a planar half-wavelength microstrip resonator, into which the SQUID-loop is integrated. The pump frequency is 1.7 GHz. The cryogenic preamplifier employs a microwave high electron mobility transistor (HEMT), located close to the SQUID sensor. Measurements of the flux noise and the fractional step rise parameter were carried out in the temperature range between 4.2 and 1.5 K. In an open loop white flux noise values of 2×10−6 Φ0/√Hz were obtained at 4.2 K.

DOI
10.1063/1.107604

Related papers

Improved sensitivity of planar microwave based RF-SQUIDs using a cryogenic HEMT preamplifier

Giorgio Fontana, R. Mezzena, Stefano Vitale +4 more

The design and performance of a planar microwave RF-SQUID (superconducting quantum interference device) read out by a cryogenic high-electron-mobility-transistor (HEMT) preamplifier are described. The SQUID sensor consists of a planar half-wavelength microstrip resonator, into which the SQUID loop is integrated. The SQUID is operated at a pump frequency of 1.7 GHz. The cryogenic preamplifier uses a microwave HEMT, located close to the SQUID sensor. Measurements of the flux noise and the fractional step rise parameter were carried out in the temperature range between 4.2 K and 1.5 K. In an open loop, a flux noise of 2*10/sup -6/ Phi /sub 0// square root Hz was measured at 4.2 K, resulting in an energy resolution of about 100 h. The design of a 3-GHz magnetometer is also described, and the preliminary results of the measurements are reported.>

IEEE Transactions on Applied Superconductivity•Mar 1, 1993•5 citations

Ultrahigh frequency thin film rf-SQUID magnetometer with a cryogenic preamplifier employing a high-electron-mobility transistor

Antonella Cavalleri, MASSIMO CERDONIO, Giorgio Fontana +5 more

Ultrahigh frequency rf-SQUID magnetometer employing a cryogenic preamplifier and a commercially available thin film rf-SQUID sensor have been designed, manufactured, and tested. The system has been operated at 316 MHz, which is the maximum pump frequency accepted by the thin film sensor. The cryogenic preamplifier has been built around a microwave high-electron-mobility transistor which was made unconditionally stable at ultrahigh frequency band by means of an appropriate circuit design, namely, a cascode configuration. The total flux noise of the magnetometer has been found to be 8.4 × 10−6Φ0/√Hz at 4.2 K and 5.8× 10−6Φ0/√Hz at 1.4 K. The temperature dependence of the fractional step rise α of the current-voltage rf characteristic has been measured to be proportional to the 2/3 power of the SQUID sensor temperature. The noise performance of the system at 4.2 K has been limited by the intrinsic SQUID noise only, in good agreement with theoretical predictions.

Review of Scientific Instruments•Nov 1, 1992•4 citations

High-TC rf superconducting quantum interference device readout with a cryogenic preamplifier

Dongfeng He, M. Tachiki, Hideo Itozaki

A high-TC rf superconducting quantum interference device (SQUID) readout with a cryogenic preamplifier was developed. The noise figure of the preamplifier at 350MHz was about 0.92dB at room temperature and 0.35dB at 77K. For a high-TC yttrium barium copper oxide rf SQUID coupled with a lumped element tank circuit with a resonant frequency of about 360MHz, the white flux noise was about 25μΦ0∕√Hz and 22μΦ0∕√Hz when the preamplifier was at room temperature and at 77K, respectively. The flux noise was only reduced by about 12% using the cryogenic preamplifier. As the thermal noise of the SQUID and the noise generated by the tank circuit are already higher than the preamplifier noise, cooling the preamplifier has only a small effect of the system noise, when the SQUID is operated at 77K. Lower operating temperatures, e.g., when using a SQUID made from MgB2, might justify the use of a cooled preamplifier.

Review of Scientific Instruments•Jun 1, 2006•0 citations

Use of super Schottky diodes in a cryogenic radio frequency superconducting quantum interference device readout

Michael Mück, Th. Becker, Christoph Heiden

We describe the fabrication and characterization of super Schottky diodes which are used in the cryogenic part of a 3 GHz radio frequency superconducting quantum interference device (rf SQUID) readout electronics. The diodes were prepared on silicon wafers with an n-doping level of 5×1024 m−3. They exhibited sensitivities of 1500 V−1 at 4.2 K, and a noise equivalent power of 2×10−15 W/√Hz was measured at 2.1 GHz. Using planar niobium 3 GHz rf SQUIDs and a cooled rf amplifier, experiments have been performed to investigate the feasibility of these super Schottky diodes for demodulation of the SQUID rf signal voltage. A simple cryogenic rf SQUID readout, employing two transistors and one super Schottky diode is described and investigated. Flux noise measurements in an open loop have been performed using this readout.

Applied Physics Letters•Jan 16, 1995•2 citations

1/f noise in radio frequency SQUIDs made of niobium thin films

Michael Mueck, John L. Clarke, Christoph Heiden

Applications of Superconducting Quantum Interference Devices (SQUIDs) usually require high sensitivity at relatively low frequencies, often down to 1 Hz or lower. Excess noise, typically with a spectral density scaling inversely as the frequency, can substantially reduce the sensitivity of SQUIDs at low frequencies. We have studied 1/f noise in niobium rf-SQUIDs in some detail. To reduce any noise contribution of the readout electronics, a cryogenic preamplifier was used. When one measures the signal voltage of the SQUID directly, a pronounced 1/f noise was observed in all samples, and was nearly independent of the bias frequency used. The crossover between 1/f and white noise moved towards higher frequencies as the bias frequency was increased, because of a lower white noise contribution. The 1/f noise scaled approximately as the inductance of the SQUID. When operated in a flux locked loop, however, no 1/f noise could be observed above 0.5 Hz. Operating a rf SQUID in a flux locked loop can thus substantially reduce 1/f noise in rf SQUIDs.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Jul 2, 1994•0 citations

Microwave rf SQUID integrated into a planar YBa2Cu3O7 resonator

Y. Zhang, Michael Mück, M. Bode +5 more

We fabricated and characterized microwave rf SQUIDs integrated into a planar, S-shaped λ/2 microstrip resonator. This 3 GHz resonator was fabricated from a pulsed-laser-deposited YBa2Cu3O7 epitaxial film. The SQUID structures incorporated double step-edge junctions and had a loop inductance of 120 pH. Such unoptimized SQUIDs operated between 4.2 and 85 K with dV/dΦ=18–20 μV/Φ0 at 77 K. At that temperature, the energy resolution of (8±2)×10−29 J/Hz above 0.1 Hz (in the best samples) was limited by the white noise, SΦ1/2=(7±1)×10−5 Φ0/Hz1/2. Optimization may increase dV/dΦ and improve the energy resolution by up to an order of magnitude.

Applied Physics Letters•May 4, 1992•46 citations
We report on the design and performance of a planar microwave rf-SQUID readout by a cryogenic preamplifier. The SQUID-sensor consists of a planar half-wavelength microstrip resonator, into which the SQUID-loop is integrated. The pump frequency is 1.7 GHz. The cryogenic preamplifier employs a microwave high electron mobility transistor (HEMT), located close to the SQUID sensor. Measurements of the flux noise and the fractional step rise parameter were carried out in the temperature range between 4.2 and 1.5 K. In an open loop white flux noise values of 2×10−6 Φ0/√Hz were obtained at 4.2 K.
The design and performance of a planar microwave RF-SQUID (superconducting quantum interference device) read out by a cryogenic high-electron-mobility-transistor (HEMT) preamplifier are described. The SQUID sensor consists of a planar half-wavelength microstrip resonator, into which the SQUID loop is integrated. The SQUID is operated at a pump frequency of 1.7 GHz. The cryogenic preamplifier uses a microwave HEMT, located close to the SQUID sensor. Measurements of the flux noise and the fractional step rise parameter were carried out in the temperature range between 4.2 K and 1.5 K. In an open loop, a flux noise of 2*10/sup -6/ Phi /sub 0// square root Hz was measured at 4.2 K, resulting in an energy resolution of about 100 h. The design of a 3-GHz magnetometer is also described, and the preliminary results of the measurements are reported.>
Ultrahigh frequency rf-SQUID magnetometer employing a cryogenic preamplifier and a commercially available thin film rf-SQUID sensor have been designed, manufactured, and tested. The system has been operated at 316 MHz, which is the maximum pump frequency accepted by the thin film sensor. The cryogenic preamplifier has been built around a microwave high-electron-mobility transistor which was made unconditionally stable at ultrahigh frequency band by means of an appropriate circuit design, namely, a cascode configuration. The total flux noise of the magnetometer has been found to be 8.4 × 10−6Φ0/√Hz at 4.2 K and 5.8× 10−6Φ0/√Hz at 1.4 K. The temperature dependence of the fractional step rise α of the current-voltage rf characteristic has been measured to be proportional to the 2/3 power of the SQUID sensor temperature. The noise performance of the system at 4.2 K has been limited by the intrinsic SQUID noise only, in good agreement with theoretical predictions.
A high-TC rf superconducting quantum interference device (SQUID) readout with a cryogenic preamplifier was developed. The noise figure of the preamplifier at 350MHz was about 0.92dB at room temperature and 0.35dB at 77K. For a high-TC yttrium barium copper oxide rf SQUID coupled with a lumped element tank circuit with a resonant frequency of about 360MHz, the white flux noise was about 25μΦ0∕√Hz and 22μΦ0∕√Hz when the preamplifier was at room temperature and at 77K, respectively. The flux noise was only reduced by about 12% using the cryogenic preamplifier. As the thermal noise of the SQUID and the noise generated by the tank circuit are already higher than the preamplifier noise, cooling the preamplifier has only a small effect of the system noise, when the SQUID is operated at 77K. Lower operating temperatures, e.g., when using a SQUID made from MgB2, might justify the use of a cooled preamplifier.
We describe the fabrication and characterization of super Schottky diodes which are used in the cryogenic part of a 3 GHz radio frequency superconducting quantum interference device (rf SQUID) readout electronics. The diodes were prepared on silicon wafers with an n-doping level of 5×1024 m−3. They exhibited sensitivities of 1500 V−1 at 4.2 K, and a noise equivalent power of 2×10−15 W/√Hz was measured at 2.1 GHz. Using planar niobium 3 GHz rf SQUIDs and a cooled rf amplifier, experiments have been performed to investigate the feasibility of these super Schottky diodes for demodulation of the SQUID rf signal voltage. A simple cryogenic rf SQUID readout, employing two transistors and one super Schottky diode is described and investigated. Flux noise measurements in an open loop have been performed using this readout.
Applications of Superconducting Quantum Interference Devices (SQUIDs) usually require high sensitivity at relatively low frequencies, often down to 1 Hz or lower. Excess noise, typically with a spectral density scaling inversely as the frequency, can substantially reduce the sensitivity of SQUIDs at low frequencies. We have studied 1/f noise in niobium rf-SQUIDs in some detail. To reduce any noise contribution of the readout electronics, a cryogenic preamplifier was used. When one measures the signal voltage of the SQUID directly, a pronounced 1/f noise was observed in all samples, and was nearly independent of the bias frequency used. The crossover between 1/f and white noise moved towards higher frequencies as the bias frequency was increased, because of a lower white noise contribution. The 1/f noise scaled approximately as the inductance of the SQUID. When operated in a flux locked loop, however, no 1/f noise could be observed above 0.5 Hz. Operating a rf SQUID in a flux locked loop can thus substantially reduce 1/f noise in rf SQUIDs.
We fabricated and characterized microwave rf SQUIDs integrated into a planar, S-shaped λ/2 microstrip resonator. This 3 GHz resonator was fabricated from a pulsed-laser-deposited YBa2Cu3O7 epitaxial film. The SQUID structures incorporated double step-edge junctions and had a loop inductance of 120 pH. Such unoptimized SQUIDs operated between 4.2 and 85 K with dV/dΦ=18–20 μV/Φ0 at 77 K. At that temperature, the energy resolution of (8±2)×10−29 J/Hz above 0.1 Hz (in the best samples) was limited by the white noise, SΦ1/2=(7±1)×10−5 Φ0/Hz1/2. Optimization may increase dV/dΦ and improve the energy resolution by up to an order of magnitude.