Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of the Optical Society of Korea

Investigation of Isotope Selective Characteristics of the Strontium Magneto-optical Trap by the Fluorescence Detection

Kwang-Hoon Ko, Do-Young Jeong, Gwon Lim, Taek-Soo Kim, Yong Ho, Hyungki Cha, You-Kyoung Lim

Published Sep 1, 2005• 8 citations
Publisher

Abstract

The strontium magneto optical trap followed by a Zeeman slower has been demonstrated. The isotope selective characteristics of the trap have been investigated. The fluorescence spectrum of the MOT was compared with those of other high resolution spectroscopic methods. The red detuned deflection beam is also considered for a more selective spectrum.

DOI
10.3807/josk.2005.9.3.087

Related papers

Measurement of the isotope selectivity of the strontium magneto-optical trap by a time-of-flight mass spectrometer

Kwang-Hoon Ko, You-Kyoung Lim, Do-Young Jeong +4 more

The isotope selectivity of the strontium (Sr) magneto-optical trap (MOT) is measured by a time-of-flight (TOF) mass spectrometer. The thermally generated Sr atoms are slowed down by the Zeeman slowing technique and trapped by the magneto-optical method. The trapped atoms are photoionized by the nonresonant two-photon ionization, and the generated ions are analyzed by the TOF mass spectrometer. The isotope selectivity of the MOT is up to approximately 2000 for 86Sr, and the overall selectivity of the system, which consists of the MOT and the mass spectrometer is also discussed.

Journal of the Optical Society of America B•Nov 29, 2006•5 citations

The progress of strontium optical clock at NIM

Shaokai Wang, Qiang Wang, Bai-Ke Lin +8 more

We report the experimental realization of88Sr magneto-optical trap (MOT) operating at the wavelength of 461 nm and 689nm. The blue MOT is loaded via a 32 cm long spin-flip type Zeeman slower which enhances the MOT population by a factor of 44. We have trapped 1.6×10888Sr atoms with the use of 679nm and 707nm repumping laser. The88Sr cloud has a temperature of about 2.3 mK, measured by recording the time evolution of the absorption signal. The 689nm laser used in our experiment has a line width of about 200Hz. To optimize the transfer efficiency, the laser spectrum is broadened by frequency modulation technique to about 2 MHz. The transfer efficiency from blue MOT to red MOT is about 20%.

European Frequency and Time Forum•Apr 1, 2010•0 citations

Efficient cooling and trapping of strontium atoms

Irène Ventrillard, Audrey Quessada, Richard P. Kovacich +4 more

We report the capture of cold strontium atoms in a magneto-optical trap (MOT) at a rate of 4 x 10(10) atoms/s. The MOT is loaded from an atomic beam decelerated by a Zeeman slower operating with a focused laser beam. The 461-nm laser, used for both cooling and trapping, was generated by sum-frequency mixing in a KTP crystal with diode lasers at 813 nm and a Nd:YAG laser at 1064 nm. As much as 115 mW of blue light was obtained.

Optics Letters•Mar 15, 2003•52 citations

Ultrasensitive detection of radioactive cesium isotopes using a magneto-optical trap

Michael D. Di Rosa, S. G. Crane, J. J. Kitten +3 more

We report the first magneto-optical trapping of radioactive 135Cs and 137Cs and a promising means for detecting these isotopes to ultrasensitive levels by using a magneto-optical trap (MOT) coupled to a mass separator. A sample containing both isotopes was placed in the source of a mass separator, ionized, mass separated, and implanted in a Zr foil within the MOT cell. After implantation, atoms were released from the foil by inductive heating and then captured in a MOT that used large diameter beams and a dry-film-coated cell to achieve high trapping efficiency. MOT fluorescence signals were measured for trapped-atom numbers from 104 to 107 and were found to increase linearly with the number of atoms implanted in the foil. The slope of signal versus number implanted was equal for each isotope to within 4%, signifying our ability to measure 137Cs/135Cs ratios to within 4% for MOT signal levels exceeding that associated with our present detection limit of 4000 trapped atoms. The MOT-based detection scheme was shown capable of suppressing interference from stable 133Cs by more than seven orders of magnitude. Including an isotopic selectivity of 105 of the mass separator, the overall suppression of 133Cs in the case of detecting either 135Cs and 137Cs is expected to exceed 1012. At present, the overall sample detection sensitivity is less than one million atoms.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Mar 29, 2002•1 citation

Ultrasensitive Detection of Radioactive Cesium Isotopes Using a Magneto-Optical Trap

Michael D. Di Rosa, S. G. Crane, J. J. Kitten +3 more

We report the first magneto-optical trapping of mdioactive {sup 135}Cs and {sup 137}Cs and a promising means for detecting these isotopes to ullrasensilive lcvels by a system coupling the magneto-optical trap (MOT) to a mass separator. The mass separator efficiently delivers a 20 kV ion beam of either isotope into a quartzcube MOT cell having in one corner a small-diameter Zr foil, on which the ion beam is focused and into which the ions are implantetl. Inductive heating of thc foil releases {approx}45% of the implanted atoms into a MOT that uses large diameter beams and a dry-film coating to capture 3% of the released vapor. MOT fluorescence signals were found to increasc linearly with the number of foil-implanted atoms over a range of 10{sup 4} to 10{sup 7} in trapped-atom number. The measured slope of MOT signal versus number implanted was equal in the case each isotope to within 4%, signifying our ability to measure {sup 137}Cs/{sup 135}Cs ratios to within 4%. The isotopic selectivities of the mass separator and MOT combine to suppress interfering signal from {sup 133}Cs by a factor of greater than 5 x 10{sup 12} in the case of detecting {sup 135}Cs or {sup 137}Cs. Our present sample detection sensitivity is one million atoms.

APS Division of Atomic, Molecular and Optical Physics Meeting Abstracts•May 1, 2002•0 citations

Single-atom detection of calcium isotopes by atom-trap trace analysis

Steven Hoekstra, A. K. Mollema, Reinhard Morgenstern +2 more

We demonstrate a combination of an isotopically purified atom beam and a magneto-optical trap which enables single-atom detection of all stable isotopes of calcium (40, 42, 43, 44, 46, and 48). These isotopes range in abundance from 96.9% $(^{40}\mathrm{Ca})$ to 0.004% $(^{46}\mathrm{Ca})$. The trap is loaded from an atomic beam which is decelerated in a Zeeman slower and subsequently deflected over an angle of 30\ifmmode^\circ\else\textdegree\fi{} by optical molasses. The isotope selectivity of the Zeeman slower and the deflection stage is investigated experimentally and compared with Monte Carlo simulations.

arXiv:physics/0501009•Physical Review A•Feb 16, 2005•18 citations
The strontium magneto optical trap followed by a Zeeman slower has been demonstrated. The isotope selective characteristics of the trap have been investigated. The fluorescence spectrum of the MOT was compared with those of other high resolution spectroscopic methods. The red detuned deflection beam is also considered for a more selective spectrum.
The isotope selectivity of the strontium (Sr) magneto-optical trap (MOT) is measured by a time-of-flight (TOF) mass spectrometer. The thermally generated Sr atoms are slowed down by the Zeeman slowing technique and trapped by the magneto-optical method. The trapped atoms are photoionized by the nonresonant two-photon ionization, and the generated ions are analyzed by the TOF mass spectrometer. The isotope selectivity of the MOT is up to approximately 2000 for 86Sr, and the overall selectivity of the system, which consists of the MOT and the mass spectrometer is also discussed.
We report the experimental realization of88Sr magneto-optical trap (MOT) operating at the wavelength of 461 nm and 689nm. The blue MOT is loaded via a 32 cm long spin-flip type Zeeman slower which enhances the MOT population by a factor of 44. We have trapped 1.6×10888Sr atoms with the use of 679nm and 707nm repumping laser. The88Sr cloud has a temperature of about 2.3 mK, measured by recording the time evolution of the absorption signal. The 689nm laser used in our experiment has a line width of about 200Hz. To optimize the transfer efficiency, the laser spectrum is broadened by frequency modulation technique to about 2 MHz. The transfer efficiency from blue MOT to red MOT is about 20%.
We report the first magneto-optical trapping of radioactive 135Cs and 137Cs and a promising means for detecting these isotopes to ultrasensitive levels by using a magneto-optical trap (MOT) coupled to a mass separator. A sample containing both isotopes was placed in the source of a mass separator, ionized, mass separated, and implanted in a Zr foil within the MOT cell. After implantation, atoms were released from the foil by inductive heating and then captured in a MOT that used large diameter beams and a dry-film-coated cell to achieve high trapping efficiency. MOT fluorescence signals were measured for trapped-atom numbers from 104 to 107 and were found to increase linearly with the number of atoms implanted in the foil. The slope of signal versus number implanted was equal for each isotope to within 4%, signifying our ability to measure 137Cs/135Cs ratios to within 4% for MOT signal levels exceeding that associated with our present detection limit of 4000 trapped atoms. The MOT-based detection scheme was shown capable of suppressing interference from stable 133Cs by more than seven orders of magnitude. Including an isotopic selectivity of 105 of the mass separator, the overall suppression of 133Cs in the case of detecting either 135Cs and 137Cs is expected to exceed 1012. At present, the overall sample detection sensitivity is less than one million atoms.
We report the first magneto-optical trapping of mdioactive {sup 135}Cs and {sup 137}Cs and a promising means for detecting these isotopes to ullrasensilive lcvels by a system coupling the magneto-optical trap (MOT) to a mass separator. The mass separator efficiently delivers a 20 kV ion beam of either isotope into a quartzcube MOT cell having in one corner a small-diameter Zr foil, on which the ion beam is focused and into which the ions are implantetl. Inductive heating of thc foil releases {approx}45% of the implanted atoms into a MOT that uses large diameter beams and a dry-film coating to capture 3% of the released vapor. MOT fluorescence signals were found to increasc linearly with the number of foil-implanted atoms over a range of 10{sup 4} to 10{sup 7} in trapped-atom number. The measured slope of MOT signal versus number implanted was equal in the case each isotope to within 4%, signifying our ability to measure {sup 137}Cs/{sup 135}Cs ratios to within 4%. The isotopic selectivities of the mass separator and MOT combine to suppress interfering signal from {sup 133}Cs by a factor of greater than 5 x 10{sup 12} in the case of detecting {sup 135}Cs or {sup 137}Cs. Our present sample detection sensitivity is one million atoms.
We demonstrate a combination of an isotopically purified atom beam and a magneto-optical trap which enables single-atom detection of all stable isotopes of calcium (40, 42, 43, 44, 46, and 48). These isotopes range in abundance from 96.9% (40Ca)(^{40}\mathrm{Ca})(40Ca) to 0.004% (46Ca)(^{46}\mathrm{Ca})(46Ca). The trap is loaded from an atomic beam which is decelerated in a Zeeman slower and subsequently deflected over an angle of 30\ifmmode^\circ\else\textdegree\fi{} by optical molasses. The isotope selectivity of the Zeeman slower and the deflection stage is investigated experimentally and compared with Monte Carlo simulations.