Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Express

Quantum nondemolition measurement of photon number via optical Kerr effect in an ultra-high-Q microtoroid cavity

Yun‐Feng Xiao, Şahin Kaya Özdemir, Venkat Gaddam, Chun-Hua Dong, Nobuyuki Imoto, Lan Yang

Published Dec 15, 2008• 88 citations
Publisher

Abstract

We theoretically investigate a quantum nondemolition (QND) measurement with optical Kerr effect in an ultra-high-Q microtoroidal system. The analytical and numerical results predict that the present QND measurement scheme possesses a high sensitivity, which allows for detecting few photons or even single photons. Ultra-high-Q toroidal microcavity may provide a novel experimental platform to study quantum physics with nonlinear optics at low light levels.

DOI
10.1364/oe.16.021462

Related papers

Quantum nondemolition measurements in optical cavities

P. M. Alsing, Gerard J Milburn, Daniel F. Walls

We analyze schemes for performing quantum nondemolition (QND) measurements in optical cavities. We consider three schemes: (1) measurement of a quadrature phase amplitude using a parametric process, (2) measurement of a quadrature phase amplitude using the optical Kerr effect in a nonlinear fiber, and (3) measurement of the photon number also using the Kerr effect in a fiber. We show that in the second scheme an enhancement of the QND effect may be obtained by making the cavity finesse for the signal larger than that for the probe.

Physical Review A•Apr 1, 1988•62 citations

Quantum nondemolition measurements of photon number in monolithic microcavities

Stepan N. Balybin, Andrey B. Matsko, Farid Ya Khalili +5 more

We revisit the idea of quantum nondemolition measurement (QND) of optical quanta via a resonantly enhanced Kerr nonlinearity taking into account quantum backaction. We show that the monolithic microcavities enable QND measurement of the number of quanta in a weak signal field using a classical probe field spatially overlapping with the signal. The phase of the probe field acquires information about the signal number of quanta without altering it due to the cross-phase modulation effect. We find the exact solution to the Heisenberg equations of motion of this system and calculate the measurement error, accounting for the optical losses in the measurement path. We identify a realistic approximation to obtain the explicit form of the final conditional quantum state of the signal field, accounting for the undesirable self-phase modulation effect and designing the optimal homodyne measurement of the probe beam to evade this effect. We show that the best modern monolithic microcavities allow achieving the measurement imprecision several times better than the standard quantum limit.

arXiv:2111.14700•Physical Review A•Jul 28, 2022•10 citations

Quantum nondemolition measurement of photon number in a lossy optical Kerr medium

N. Imoto, Shigeru Saito

A photon-number quantum nondemolition (QND) measurement theory that takes dissipative losses into account is presented. A QND measurement criterion is developed to determine the feasibility of QND measurements in a lossy optical medium. Using an analysis based on loss-error characteristics, we examine a lossy Kerr medium. We obtain restrictions on the losses and requirements for the nonlinearity and signal and probe powers necessary to observe the QND effect. We calculate the expected results for an experimental system meeting such requirements. We conclude that QND measurements are possible in existing media.

Physical Review A•Jan 1, 1989•35 citations

Quantum Nondemolition Measurement of Photon Number and Number-Phase Minimum Uncertainty State

Y. Yamamoto, N. Imoto, S. Machida

Two strategies for beating the standard quantum limit in preparation and measurement of optical quantum states are discussed. One is the quantum nondemolition (QND) measurement of the photon number using the optical Kerr effect. The other is the generation of number-phase minimum uncertainty states using either controlled reduction of the wave function by QND measurement and feedback or feedforward, or phase sensitive deamplification in a highly saturated laser oscillator with suppressed-pump-fluctuation.

Advanced series in applied physics•Jan 1, 1997•1 citation

Quantum nondemolition measurements in an optical-fiber ring resonator

Hans‐A. Bachor, M. D. Levenson, Daniel F. Walls +2 more

A quantum nondemolition (QND) measurement scheme utilizing a Kerr medium enclosed in a resonant cavity is described and analyzed theoretically. The theory demonstrates that the conditions for QND can be met in such a device. An experimental realization in the form of an optical-fiber ring resonator has been constructed and initial experimental results are presented.

Physical Review A•Jul 1, 1988•51 citations

Intracavity squeezing for a Kerr quantum nondemolition measurement scheme

Dariya Salykina, Stepan N. Balybin, Farid Ya Khalili

In the work by Balybin et al. [Phys. Rev. A 108, 053708 (2023)], the scheme of quantum nondemolition measurement of optical quanta that uses a resonantly enhanced Kerr nonlinearity in the optical microresonator, presqueezing of the probe beam, and its parametric amplification before the detection was analyzed theoretically. It was shown that the main factor that limits the sensitivity of the considered scheme is the interplay of optical losses and the nonlinear self-phase modulation (SPM) effect. Here we show that using the intracavity squeezing of the probe beam in this scheme, it is possible to cancel out the SPM effect. In this case, the sensitivity will be limited only by the available power in the pump beam and by the input/output losses in the signal beam. Our estimates show that using the best optical microresonators currently available, the sensitivity for the intracavity photon number approaching the single-photon one can be achieved. Therefore, this scheme could be of interest for optical quantum information processing tasks.

arXiv:2409.10222•Physical Review A•Jan 23, 2025•2 citations
We theoretically investigate a quantum nondemolition (QND) measurement with optical Kerr effect in an ultra-high-Q microtoroidal system. The analytical and numerical results predict that the present QND measurement scheme possesses a high sensitivity, which allows for detecting few photons or even single photons. Ultra-high-Q toroidal microcavity may provide a novel experimental platform to study quantum physics with nonlinear optics at low light levels.
We analyze schemes for performing quantum nondemolition (QND) measurements in optical cavities. We consider three schemes: (1) measurement of a quadrature phase amplitude using a parametric process, (2) measurement of a quadrature phase amplitude using the optical Kerr effect in a nonlinear fiber, and (3) measurement of the photon number also using the Kerr effect in a fiber. We show that in the second scheme an enhancement of the QND effect may be obtained by making the cavity finesse for the signal larger than that for the probe.
We revisit the idea of quantum nondemolition measurement (QND) of optical quanta via a resonantly enhanced Kerr nonlinearity taking into account quantum backaction. We show that the monolithic microcavities enable QND measurement of the number of quanta in a weak signal field using a classical probe field spatially overlapping with the signal. The phase of the probe field acquires information about the signal number of quanta without altering it due to the cross-phase modulation effect. We find the exact solution to the Heisenberg equations of motion of this system and calculate the measurement error, accounting for the optical losses in the measurement path. We identify a realistic approximation to obtain the explicit form of the final conditional quantum state of the signal field, accounting for the undesirable self-phase modulation effect and designing the optimal homodyne measurement of the probe beam to evade this effect. We show that the best modern monolithic microcavities allow achieving the measurement imprecision several times better than the standard quantum limit.
A photon-number quantum nondemolition (QND) measurement theory that takes dissipative losses into account is presented. A QND measurement criterion is developed to determine the feasibility of QND measurements in a lossy optical medium. Using an analysis based on loss-error characteristics, we examine a lossy Kerr medium. We obtain restrictions on the losses and requirements for the nonlinearity and signal and probe powers necessary to observe the QND effect. We calculate the expected results for an experimental system meeting such requirements. We conclude that QND measurements are possible in existing media.
Two strategies for beating the standard quantum limit in preparation and measurement of optical quantum states are discussed. One is the quantum nondemolition (QND) measurement of the photon number using the optical Kerr effect. The other is the generation of number-phase minimum uncertainty states using either controlled reduction of the wave function by QND measurement and feedback or feedforward, or phase sensitive deamplification in a highly saturated laser oscillator with suppressed-pump-fluctuation.
In the work by Balybin et al. [Phys. Rev. A 108, 053708 (2023)], the scheme of quantum nondemolition measurement of optical quanta that uses a resonantly enhanced Kerr nonlinearity in the optical microresonator, presqueezing of the probe beam, and its parametric amplification before the detection was analyzed theoretically. It was shown that the main factor that limits the sensitivity of the considered scheme is the interplay of optical losses and the nonlinear self-phase modulation (SPM) effect. Here we show that using the intracavity squeezing of the probe beam in this scheme, it is possible to cancel out the SPM effect. In this case, the sensitivity will be limited only by the available power in the pump beam and by the input/output losses in the signal beam. Our estimates show that using the best optical microresonators currently available, the sensitivity for the intracavity photon number approaching the single-photon one can be achieved. Therefore, this scheme could be of interest for optical quantum information processing tasks.