Physics Today

New Atomic Magnetometer Achieves Subfemtotesla Sensitivity

Richard Fitzgerald

Published Jul 1, 2003• 10 citations
Publisher

Abstract

In a field dominated by superconducting quantum interference devices (SQUIDs), a rival technique has gotten a boost by operating in a new parameter regime.
DOI
10.1063/1.1603066

Related papers

Harnessing nonlinearity for linear measurements

Hendrik Bluhm

Researchers develop a new type of superconducting quantum interference device (SQUID) with significantly enhanced sensitivity and bandwidth, which can function as a general-purpose magnetic sensor.

Physics•Apr 4, 2011•1 citation

Prospects for atomic magnetometers employing hollow core optical fibre

C. N. Ironside, Krishna Seunarine, Giuseppe Tandoi +1 more

Presently, among the most demanding applications for highly sensitive magnetometers are Magnetocardiography (MCG) and Magnetoencephalography (MEG), where sensitivities of around 1pT.Hz-1/2 and 1fT.Hz-1/2 are required. Cryogenic Superconducting Quantum Interference Devices (SQUIDs) are currently used as the magnetometers. However, there has been some recent work on replacing these devices with magnetometers based on atomic spectroscopy and operating at room temperature. There are demonstrations of MCG and MEG signals measured using atomic spectroscopy These atomic magnetometers are based on chip-scale microfabricated components. In this paper we discuss the prospects of using photonic crystal optical fibres or hollow core fibres (HCFs) loaded with Rb vapour in atomic magnetometer systems. We also consider new components for magnetometers based on mode-locked semiconductor lasers for measuring magnetic field via coherent population trapping (CPT) in Rb loaded HCFs.

Photonics and Micro- and Nano-structured Materials•Jan 20, 2012•1 citation

Sensitive superconducting quantum magnetometer

B. V. Vasiliev, V. G. Grebinnik, V. G. Simkin

•Jan 1, 1973•1 citation

A compact and closed-loop spin-exchange relaxation-free atomic magnetometer for wearable magnetoencephalography

Qingqian Guo, Tao Hu, Xiaoyu Feng +10 more

Atomic magnetometers operated in the spin-exchange relaxation-free (SERF) regime are the promising sensor to replace superconducting quantum interference devices (SQUIDs) in the biomagnetism field. The SERF magnetometer with compact size and good performance is crucial to the new generation of wearable magnetoencephalography (MEG) system. In this paper, we developed a compact and closed-loop SERF magnetometer with the dimensions of 15.0×22.0×30.0 mm3 based on a single-beam configuration. The bandwidth of the magnetometer was extended to 675 Hz while the sensitivity was maintained at 22 fT/Hz1/2. A nearly 3-fold enhancement of the bandwidth was obtained in comparison with the open-loop control. The implementation of the closed-loop control also greatly improved the dynamic range, enabling the magnetometer to be robust against the disturbance of the ambient field. Moreover, the magnetometer was successfully applied for the detection of human α-rhythm and auditory evoked fields (AEFs), which demonstrated the potential to be extended to multi-channel MEG measurements for future neuroscience studies.

Chinese Physics B•Jul 5, 2022•12 citations

Highly sensitive miniature SQUID magnetometer fabricated with cross-type Josephson tunnel junctions

Matthias Schmelz, Ronny Stolz, V. Zakosarenko +4 more

Physica C Superconductivity•Mar 1, 2012•19 citations

Broadband Superconducting Quantum Magnetometer

R.A. Kamper, M. B. Simmonds

We describe the design, operation, and performance of a superconducting quantum interference device (SQUID) which operates at a frequency of 9 GHz. It is sensitive to variations of magnetic field in a frequency band from 0 to 1 GHz.

Applied Physics Letters•Apr 15, 1972•62 citations
Presently, among the most demanding applications for highly sensitive magnetometers are Magnetocardiography (MCG) and Magnetoencephalography (MEG), where sensitivities of around 1pT.Hz-1/2 and 1fT.Hz-1/2 are required. Cryogenic Superconducting Quantum Interference Devices (SQUIDs) are currently used as the magnetometers. However, there has been some recent work on replacing these devices with magnetometers based on atomic spectroscopy and operating at room temperature. There are demonstrations of MCG and MEG signals measured using atomic spectroscopy These atomic magnetometers are based on chip-scale microfabricated components. In this paper we discuss the prospects of using photonic crystal optical fibres or hollow core fibres (HCFs) loaded with Rb vapour in atomic magnetometer systems. We also consider new components for magnetometers based on mode-locked semiconductor lasers for measuring magnetic field via coherent population trapping (CPT) in Rb loaded HCFs.
Atomic magnetometers operated in the spin-exchange relaxation-free (SERF) regime are the promising sensor to replace superconducting quantum interference devices (SQUIDs) in the biomagnetism field. The SERF magnetometer with compact size and good performance is crucial to the new generation of wearable magnetoencephalography (MEG) system. In this paper, we developed a compact and closed-loop SERF magnetometer with the dimensions of 15.0×22.0×30.0 mm3 based on a single-beam configuration. The bandwidth of the magnetometer was extended to 675 Hz while the sensitivity was maintained at 22 fT/Hz1/2. A nearly 3-fold enhancement of the bandwidth was obtained in comparison with the open-loop control. The implementation of the closed-loop control also greatly improved the dynamic range, enabling the magnetometer to be robust against the disturbance of the ambient field. Moreover, the magnetometer was successfully applied for the detection of human α-rhythm and auditory evoked fields (AEFs), which demonstrated the potential to be extended to multi-channel MEG measurements for future neuroscience studies.