Experiments on the Josephson junction amplifier. Final report (Part 3)

Aldert van der Ziel, Hyeokmin Choe

Published Mar 1, 1972• 0 citations
OpenAlex

Related papers

Externally pumped millimeter-wave Josephson-junction parametric amplifier

Mogens T. Levinsen, N. F. Pedersen, O. H. Soerensen +2 more

A unified theory of the singly and doubly degenerate Josephson-junction parametric amplifier is presented. Experiments with single junctions on both amplifier modes at frequencies 10, 35, and 70 GHz are discussed. Low-noise temperature (∼100 K, single sideband (SSB)) and reasonable gain (∼8 dB) were obtained at 35 GHz in the singly degenerate mode. On the basis of the theory and experiments, a general procedure for optimizing junction parameters is discussed and illustrated by the specific design of a 100-GHz amplifier.

IEEE Transactions on Electron Devices•Oct 1, 1980•17 citations

Advanced Concepts in Josephson Junction Reflection Amplifiers

Pasi Lähteenmäki, Visa Vesterinen, Juha Hassel +3 more

arXiv:1405.5019•Journal of Low Temperature Physics•Apr 2, 2014•19 citations

Microwave parametric amplifiers using externally pumped Josephson junctions

O. H. Soerensen, J. Mygind, N. F. Pedersen

Externally pumped parametric amplifiers are discussed. Theory and experiments on the singly degenerate parametric amplifier based on a Josephson junction are presented. Advantages and limitations of the singly degenerate and doubly degenerate parametric amplifiers are discussed. Some plans and proposals for future research are presented.

AIP conference proceedings•Jan 1, 1978•6 citations

Optimizing the Josephson Parametric Amplifier - A numerical study

Zlatko Minev, Rajamani Vijayaraghavan, Irfan A. Siddiqi

Bulletin of the American Physical Society•Mar 22, 2011•0 citations

Josephson Junctions: Fabrication and Applications for the Axion Dark Matter eXperiment

Jonah Sachs

The observation of axions could revolutionize the world of physics. Through microwave frequency cavity readout of the photons associated with these axions, the ADMX project at WashU utilizes multiple different forms of the Josephson junction (JJ), a superconductive circuit element. The physics behind the JJ are essential to understanding its operation for resonant cavity readout in addition to parametric amplification. Parametric amplifiers produced using JJs can approach the signal-to-noise ratio set by quantum mechanics, and prove essential for the amplification chain used by the ADMX experiment for axionic detection. The limits of these amplifiers are set by the noise tuning source used for calibration. This tuning device can be used to solve for the intrinsic gain and added noise present within the amplifier, which defines the effectiveness of the amplifier. Multiple models for a tuning device, based upon different models of noise, will be analyzed. Also discussed is the fabrication behind the tunnel junction-based noise source, in addition to the Dolan bridge procedure and corresponding physics used for design of experiment and parameter manipulation.

•Jan 1, 2025•0 citations

Design and Calibration of an Improved Josephson Parametric Amplifier

William Kindel, Hsiang-Sheng Ku, F. Mallet +4 more

Bulletin of the American Physical Society•Mar 21, 2011•0 citations
A unified theory of the singly and doubly degenerate Josephson-junction parametric amplifier is presented. Experiments with single junctions on both amplifier modes at frequencies 10, 35, and 70 GHz are discussed. Low-noise temperature (∼100 K, single sideband (SSB)) and reasonable gain (∼8 dB) were obtained at 35 GHz in the singly degenerate mode. On the basis of the theory and experiments, a general procedure for optimizing junction parameters is discussed and illustrated by the specific design of a 100-GHz amplifier.
The observation of axions could revolutionize the world of physics. Through microwave frequency cavity readout of the photons associated with these axions, the ADMX project at WashU utilizes multiple different forms of the Josephson junction (JJ), a superconductive circuit element. The physics behind the JJ are essential to understanding its operation for resonant cavity readout in addition to parametric amplification. Parametric amplifiers produced using JJs can approach the signal-to-noise ratio set by quantum mechanics, and prove essential for the amplification chain used by the ADMX experiment for axionic detection. The limits of these amplifiers are set by the noise tuning source used for calibration. This tuning device can be used to solve for the intrinsic gain and added noise present within the amplifier, which defines the effectiveness of the amplifier. Multiple models for a tuning device, based upon different models of noise, will be analyzed. Also discussed is the fabrication behind the tunnel junction-based noise source, in addition to the Dolan bridge procedure and corresponding physics used for design of experiment and parameter manipulation.