Applied Physics B

A flexible optimization method for scaling surface-electrode ion traps

Wei Liu, Shuming Chen, Wei Wu

Published Oct 23, 2014• 3 citations
Publisher
DOI
10.1007/s00340-014-5939-2

Related papers

Optimization of parameters of a surface-electrode ion trap and experimental study of influences of surface on ion lifetime

Bao-Quan Ou, Jie Zhang, Xinfang Zhang +5 more

Science China Physics Mechanics and Astronomy•Oct 24, 2016•16 citations

Analytical methods for design of surface-electrode ion traps

Janus H. Wesenberg, Jason Amini, R. B. Blakestad +11 more

Bulletin of the American Physical Society•Jun 7, 2007•1 citation

Characterizing the spatial potential of an ion trap chip

Qingqing Qin, Ting Chen, Xinfang Zhang +6 more

The accurate characterization of the spatial electric field generated by electrodes in a surface electrode trap is of paramount importance. In this pursuit, we have identified a simple yet highly precise parametric expression to describe the spatial field of a rectangular-shaped electrode. Leveraging this expression, we introduced an optimization method designed to accurately characterize the axial electric field intensity produced by the powered electrode and the stray field. Distinct from the existing methods, our approach integrates a diverse array of experimental data, including the equilibrium positions of ions in a linear string, the equilibrium positions of single trapped ions, and trap frequencies, to effectively reduce the systematic errors. This approach provides considerable flexibility in voltage settings for data acquisition, making it especially advantageous for surface electrode traps where the trapping height of ion probes may vary with casual voltage settings. In our experimental demonstration, we successfully minimized the discrepancy between observations and model predictions to a remarkable degree. The relative errors of secular frequencies were contained within ±0.5%, and the positional error of ions was constrained to less than 1.2 μm, which surpasses the performance of current methodologies.

arXiv:2301.00559•Chip•Jan 1, 2025•5 citations

Surface-electrode ion trap development

Timur Abbasov, Sergei A. Zibrov, I. Sherstov

Письма в Журнал экспериментальной и теоретической физики•Dec 15, 2023•0 citations

Optimization and implementation of a surface-electrode ion trap junction

Chi Zhang, Karan K. Mehta, Jonathan Home

Abstract We describe the design of a surface-electrode ion trap junction, which is a key element for large-scale ion trap arrays. A bi-objective optimization method is used for designing the electrodes, which maintains the total pseudo-potential curvature while minimizing the axial pseudo-potential gradient along the ion transport path. To facilitate the laser beam delivery for parallel operations in multiple trap zones, we implemented integrated optics on each arm of this X-junction trap. The layout of the trap chip for commercial foundry fabrication is presented. This work suggests routes to improving ion trap junction performance in scalable implementations. Together with integrated optical addressing, this contributes to modular trapped-ion quantum computing in interconnected two-dimensional arrays.

arXiv:2201.12579•New Journal of Physics•Jul 1, 2022•10 citations

Design Optimization for Anharmonic Linear Surface-Electrode Ion Trap

Wei Liu, Shuming Chen, Ping‐Xing Chen +1 more

An accurate and rapid method is proposed to optimize anharmonic linear surface-electrode ion trap design. Based on the method, we analyze the impact of the architectural parameters, including the width, number, and applied voltage of prerequisite active electrodes, on the number and spacing of trapped ions. Sets of optimal anharmonic trap design are given. Then the optimal designs are verified by using an ant colony optimization algorithm. The results show that the maximum ion position errors and maximum ion spacing errors are less than 1 μm up to 80. The mean of the maximum errors is nearly linear with respect to the number of trapped ions.

Chinese Physics Letters•Nov 1, 2014•4 citations
The accurate characterization of the spatial electric field generated by electrodes in a surface electrode trap is of paramount importance. In this pursuit, we have identified a simple yet highly precise parametric expression to describe the spatial field of a rectangular-shaped electrode. Leveraging this expression, we introduced an optimization method designed to accurately characterize the axial electric field intensity produced by the powered electrode and the stray field. Distinct from the existing methods, our approach integrates a diverse array of experimental data, including the equilibrium positions of ions in a linear string, the equilibrium positions of single trapped ions, and trap frequencies, to effectively reduce the systematic errors. This approach provides considerable flexibility in voltage settings for data acquisition, making it especially advantageous for surface electrode traps where the trapping height of ion probes may vary with casual voltage settings. In our experimental demonstration, we successfully minimized the discrepancy between observations and model predictions to a remarkable degree. The relative errors of secular frequencies were contained within ±0.5%, and the positional error of ions was constrained to less than 1.2 μm, which surpasses the performance of current methodologies.
Abstract We describe the design of a surface-electrode ion trap junction, which is a key element for large-scale ion trap arrays. A bi-objective optimization method is used for designing the electrodes, which maintains the total pseudo-potential curvature while minimizing the axial pseudo-potential gradient along the ion transport path. To facilitate the laser beam delivery for parallel operations in multiple trap zones, we implemented integrated optics on each arm of this X-junction trap. The layout of the trap chip for commercial foundry fabrication is presented. This work suggests routes to improving ion trap junction performance in scalable implementations. Together with integrated optical addressing, this contributes to modular trapped-ion quantum computing in interconnected two-dimensional arrays.
An accurate and rapid method is proposed to optimize anharmonic linear surface-electrode ion trap design. Based on the method, we analyze the impact of the architectural parameters, including the width, number, and applied voltage of prerequisite active electrodes, on the number and spacing of trapped ions. Sets of optimal anharmonic trap design are given. Then the optimal designs are verified by using an ant colony optimization algorithm. The results show that the maximum ion position errors and maximum ion spacing errors are less than 1 μm up to 80. The mean of the maximum errors is nearly linear with respect to the number of trapped ions.