Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2301.00559 · Chip

Characterizing the spatial potential of an ion trap chip

Qingqing Qin, Ting Chen, Xinfang Zhang, Bao-Quan Ou, Jie Zhang, Chun-Wang Wu, Yi Xie, Wei Wu, Ping‐Xing Chen

Published Jan 1, 2025• 5 citations
arXivHTMLPDF

Abstract

The accurate characterization of the spatial electric field generated by electrodes in a surface electrode trap is of paramount importance. In this pursuit, we have identified a simple yet highly precise parametric expression to describe the spatial field of a rectangular-shaped electrode. Leveraging this expression, we introduced an optimization method designed to accurately characterize the axial electric field intensity produced by the powered electrode and the stray field. Distinct from the existing methods, our approach integrates a diverse array of experimental data, including the equilibrium positions of ions in a linear string, the equilibrium positions of single trapped ions, and trap frequencies, to effectively reduce the systematic errors. This approach provides considerable flexibility in voltage settings for data acquisition, making it especially advantageous for surface electrode traps where the trapping height of ion probes may vary with casual voltage settings. In our experimental demonstration, we successfully minimized the discrepancy between observations and model predictions to a remarkable degree. The relative errors of secular frequencies were contained within ±0.5%, and the positional error of ions was constrained to less than 1.2 μm, which surpasses the performance of current methodologies.

DOI
10.1016/j.chip.2024.100126

Related papers

Creating equally spaced linear ion string in a surface-electrode trap by feedback control

Yi Xie, Xinfang Zhang, Bao-Quan Ou +5 more

A feedback control method for producing an equidistant ion string in a surface-electrode ion trap has been experimentally demonstrated. This method features three advantages: (i) The optimal voltage can be constrained within the specified reachable range. (ii) The height of trapped ions from the trap surface can be maintained at the same value when strings with different number of ions or with different ion spacings are to be trapped. (iii) This method is resistant to a stray electric field near the trap. By this method, the asymmetry of the ion string caused by a stray field is minimized. The robustness of trapping a variable number of ions at the same potential and the dependency of the axial frequency on the number of ions are also investigated experimentally. This work would be a practical method to create a linear ion string with a large number of ions and may find applications in large-scale quantum computing, quantum simulation, and phase transition studies utilizing homogeneous ion strings.

Physical Review A•Mar 31, 2017•17 citations

Method for Estimating Locations of Laser-Induced Stray Charges on Surface-Electrode Ion Traps Using Secular Frequency Shift at Multiple Ion Positions

Changhyun Jung, Junho Jeong, Seungwoo Yoo +2 more

This paper develops a method for estimating the locations of laser-induced stray charges on surface-electrode ion traps. How the electric potential at the trapped-ion location changes in the presence of laser-induced stray charges is theoretically modeled, and the magnitude of the shift in the secular frequency of a trapped ion is derived from the model. This model can be used inversely to find the locations of stray charges from the secular frequency shift under certain conditions. Typically, this inverse relationship is not unique. However, in surface-electrode ion traps, the secular frequency shift caused by the stray charges can be measured at multiple ion positions, and therefore, the required number of secular-frequency-shift measurements can be performed to determine the stray-charge locations uniquely. This model is experimentally evaluated by intentionally producing electric charges at a single location by irradiating a laser onto that spot and by measuring the resulting secular frequency shift. The location of produced charges is estimated from the measured result, and the estimated location is consistent with where the laser is irradiating. The developed method can be applied to characterize the laser-induced stray charges, which in turn can be used to design experiments to avoid or reduce the occurrence of stray charges.

Physical Review Applied•Jul 17, 2023•2 citations

Design Optimization for Anharmonic Linear Surface-Electrode Ion Trap

Wei Liu, Shuming Chen, Ping‐Xing Chen +1 more

An accurate and rapid method is proposed to optimize anharmonic linear surface-electrode ion trap design. Based on the method, we analyze the impact of the architectural parameters, including the width, number, and applied voltage of prerequisite active electrodes, on the number and spacing of trapped ions. Sets of optimal anharmonic trap design are given. Then the optimal designs are verified by using an ant colony optimization algorithm. The results show that the maximum ion position errors and maximum ion spacing errors are less than 1 μm up to 80. The mean of the maximum errors is nearly linear with respect to the number of trapped ions.

Chinese Physics Letters•Nov 1, 2014•4 citations

Characterization of Inner Control Electrode Shapes for Multi-Layer Surface-Electrode Ion Traps

Florian Ungerechts, Brigitte Kaune, Christian Ospelkaus

Microfabricated surface-electrode traps are a scalable platform for trapped-ion quantum processors. Recent advances in fabrication techniques have enabled the design of increasingly complex multi-layer structures. Yet the control electrodes remain mostly unchanged and of rectangular shape. We systematically analyze asymmetric inner control electrode shapes for simultaneous axial and radial control in multi-layer surface traps, characterize and compare a selection of different shapes, and verify their capabilities in realistic use-case scenarios for ion transport and micromotion compensation. Eliminating the need for the commonly used additional outer control electrodes, asymmetric inner control electrodes increase the compactness and space efficiency of surface-electrode traps while concurrently reducing the number of control signals. The improved control voltage efficiency of using solely inner electrodes enables the device's entire direct-current (DC) supply to be provided by integrated Cryo-CMOS circuits, further enhancing the scalability of the processor.

quant-pharXiv:2603.00348•Quantum Science and Technology•Mar 3, 2026•0 citations

Design optimization and precision requirements of an endcap ion trap for single-ion optical clock applications

Chaowei Wang, Shaoyang Dai, Yani Zuo +1 more

Ion traps serve as the venue for confining ions and exciting ionic transitions in ion optical clocks, where the geometric dimensions of the electrodes within the ion trap directly impact the performance metrics of the ion optical clocks. In this study, the finite element analysis method was employed to simulate the relationship between the electric field distribution and the dimensions of the electrodes in an endcap ion trap. The simulation data were subjected to curve fitting, with trap depth and potential anharmonicity utilized as the primary evaluation criteria for optimizing ion trap design. The results indicate that the ion trap demonstrates optimal performance when the distance between the radio frequency electrodes is reduced to 0.686 mm, and it is suggested that the chamfer width of the endcap electrode extension be 0.6 mm. Based on this, the study further explored the machining accuracy of certain dimensions, concluding that the required high machining accuracy values for the radio frequency electrodes and the endcap electrodes are ±3 and ±7 μm, respectively, while the aperture machining accuracy requirements are ±3 and ±22 μm, respectively. In addition, the simulation results suggest that a conical surface on the radio frequency electrodes with a height of ∼0.08 mm aids in reducing anharmonicity, although a spherical end surface does not notably improve the electric field distribution. These findings provide a valuable reference for the optimized design and machining of ion traps.

AIP Advances•May 1, 2025•2 citations

Controlling trapping potentials and stray electric fields in a microfabricated ion trap through design and compensation

S. Charles Doret, Jason Amini, Kenneth Wright +8 more

Recent advances in quantum information processing with trapped ions have demonstrated the need for new ion trap architectures capable of holding and manipulating chains of many (>10) ions. Here we present the design and detailed characterization of a new linear trap, microfabricated with scalable complementary metal-oxide-semiconductor (CMOS) techniques, that is well-suited to this challenge. Forty-four individually controlled dc electrodes provide the many degrees of freedom required to construct anharmonic potential wells, shuttle ions, merge and split ion chains, precisely tune secular mode frequencies, and adjust the orientation of trap axes. Microfabricated capacitors on dc electrodes suppress radio-frequency pickup and excess micromotion, while a top-level ground layer simplifies modeling of electric fields and protects trap structures underneath. A localized aperture in the substrate provides access to the trapping region from an oven below, permitting deterministic loading of particular isotopic/elemental sequences via species-selective photoionization. The shapes of the aperture and radio-frequency electrodes are optimized to minimize perturbation of the trapping pseudopotential. Laboratory experiments verify simulated potentials and characterize trapping lifetimes, stray electric fields, and ion heating rates, while measurement and cancellation of spatially-varying stray electric fields permits the formation of nearly-equally spaced ion chains.

arXiv:1204.4147•New Journal of Physics•Jul 6, 2012•79 citations
The accurate characterization of the spatial electric field generated by electrodes in a surface electrode trap is of paramount importance. In this pursuit, we have identified a simple yet highly precise parametric expression to describe the spatial field of a rectangular-shaped electrode. Leveraging this expression, we introduced an optimization method designed to accurately characterize the axial electric field intensity produced by the powered electrode and the stray field. Distinct from the existing methods, our approach integrates a diverse array of experimental data, including the equilibrium positions of ions in a linear string, the equilibrium positions of single trapped ions, and trap frequencies, to effectively reduce the systematic errors. This approach provides considerable flexibility in voltage settings for data acquisition, making it especially advantageous for surface electrode traps where the trapping height of ion probes may vary with casual voltage settings. In our experimental demonstration, we successfully minimized the discrepancy between observations and model predictions to a remarkable degree. The relative errors of secular frequencies were contained within ±0.5%, and the positional error of ions was constrained to less than 1.2 μm, which surpasses the performance of current methodologies.
A feedback control method for producing an equidistant ion string in a surface-electrode ion trap has been experimentally demonstrated. This method features three advantages: (i) The optimal voltage can be constrained within the specified reachable range. (ii) The height of trapped ions from the trap surface can be maintained at the same value when strings with different number of ions or with different ion spacings are to be trapped. (iii) This method is resistant to a stray electric field near the trap. By this method, the asymmetry of the ion string caused by a stray field is minimized. The robustness of trapping a variable number of ions at the same potential and the dependency of the axial frequency on the number of ions are also investigated experimentally. This work would be a practical method to create a linear ion string with a large number of ions and may find applications in large-scale quantum computing, quantum simulation, and phase transition studies utilizing homogeneous ion strings.
This paper develops a method for estimating the locations of laser-induced stray charges on surface-electrode ion traps. How the electric potential at the trapped-ion location changes in the presence of laser-induced stray charges is theoretically modeled, and the magnitude of the shift in the secular frequency of a trapped ion is derived from the model. This model can be used inversely to find the locations of stray charges from the secular frequency shift under certain conditions. Typically, this inverse relationship is not unique. However, in surface-electrode ion traps, the secular frequency shift caused by the stray charges can be measured at multiple ion positions, and therefore, the required number of secular-frequency-shift measurements can be performed to determine the stray-charge locations uniquely. This model is experimentally evaluated by intentionally producing electric charges at a single location by irradiating a laser onto that spot and by measuring the resulting secular frequency shift. The location of produced charges is estimated from the measured result, and the estimated location is consistent with where the laser is irradiating. The developed method can be applied to characterize the laser-induced stray charges, which in turn can be used to design experiments to avoid or reduce the occurrence of stray charges.
An accurate and rapid method is proposed to optimize anharmonic linear surface-electrode ion trap design. Based on the method, we analyze the impact of the architectural parameters, including the width, number, and applied voltage of prerequisite active electrodes, on the number and spacing of trapped ions. Sets of optimal anharmonic trap design are given. Then the optimal designs are verified by using an ant colony optimization algorithm. The results show that the maximum ion position errors and maximum ion spacing errors are less than 1 μm up to 80. The mean of the maximum errors is nearly linear with respect to the number of trapped ions.
Microfabricated surface-electrode traps are a scalable platform for trapped-ion quantum processors. Recent advances in fabrication techniques have enabled the design of increasingly complex multi-layer structures. Yet the control electrodes remain mostly unchanged and of rectangular shape. We systematically analyze asymmetric inner control electrode shapes for simultaneous axial and radial control in multi-layer surface traps, characterize and compare a selection of different shapes, and verify their capabilities in realistic use-case scenarios for ion transport and micromotion compensation. Eliminating the need for the commonly used additional outer control electrodes, asymmetric inner control electrodes increase the compactness and space efficiency of surface-electrode traps while concurrently reducing the number of control signals. The improved control voltage efficiency of using solely inner electrodes enables the device's entire direct-current (DC) supply to be provided by integrated Cryo-CMOS circuits, further enhancing the scalability of the processor.
Ion traps serve as the venue for confining ions and exciting ionic transitions in ion optical clocks, where the geometric dimensions of the electrodes within the ion trap directly impact the performance metrics of the ion optical clocks. In this study, the finite element analysis method was employed to simulate the relationship between the electric field distribution and the dimensions of the electrodes in an endcap ion trap. The simulation data were subjected to curve fitting, with trap depth and potential anharmonicity utilized as the primary evaluation criteria for optimizing ion trap design. The results indicate that the ion trap demonstrates optimal performance when the distance between the radio frequency electrodes is reduced to 0.686 mm, and it is suggested that the chamfer width of the endcap electrode extension be 0.6 mm. Based on this, the study further explored the machining accuracy of certain dimensions, concluding that the required high machining accuracy values for the radio frequency electrodes and the endcap electrodes are ±3 and ±7 μm, respectively, while the aperture machining accuracy requirements are ±3 and ±22 μm, respectively. In addition, the simulation results suggest that a conical surface on the radio frequency electrodes with a height of ∼0.08 mm aids in reducing anharmonicity, although a spherical end surface does not notably improve the electric field distribution. These findings provide a valuable reference for the optimized design and machining of ion traps.
Recent advances in quantum information processing with trapped ions have demonstrated the need for new ion trap architectures capable of holding and manipulating chains of many (>10) ions. Here we present the design and detailed characterization of a new linear trap, microfabricated with scalable complementary metal-oxide-semiconductor (CMOS) techniques, that is well-suited to this challenge. Forty-four individually controlled dc electrodes provide the many degrees of freedom required to construct anharmonic potential wells, shuttle ions, merge and split ion chains, precisely tune secular mode frequencies, and adjust the orientation of trap axes. Microfabricated capacitors on dc electrodes suppress radio-frequency pickup and excess micromotion, while a top-level ground layer simplifies modeling of electric fields and protects trap structures underneath. A localized aperture in the substrate provides access to the trapping region from an oven below, permitting deterministic loading of particular isotopic/elemental sequences via species-selective photoionization. The shapes of the aperture and radio-frequency electrodes are optimized to minimize perturbation of the trapping pseudopotential. Laboratory experiments verify simulated potentials and characterize trapping lifetimes, stray electric fields, and ion heating rates, while measurement and cancellation of spatially-varying stray electric fields permits the formation of nearly-equally spaced ion chains.