Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Review of Scientific Instruments

Superconducting microwave resonator for millikelvin magnetic resonance force microscopy

H. Jonathon Mamin, Raffi Budakian, D. Rugar

Published May 1, 2003• 18 citations
Publisher

Abstract

We have fabricated a superconducting resonator capable of generating a strong microwave magnetic field in a small (100 μm) volume for low temperature magnetic resonance experiments. While the resonator was specifically developed for use at millikelvin temperatures in a dilution refrigerator, where the total cooling power is limited to a few hundred microwatts, it is also useful at temperatures up to 5 K. The resonator consists of a 220 μm diameter, 2-1/2 turn niobium coil resonating with a short section of niobium microstripline. At a resonance frequency of 3 GHz, the loaded Q of the resonator was 780. The field strength was characterized by performing electron spin nutations. Operating at 100 mK with 320 μW of dissipated power, the resonator generated a field of 4 G at a distance of 100 μm from the coil.

DOI
10.1063/1.1564278

Related papers

A near-field scanning microwave microscope based on a superconducting resonator for low power measurements

Sebastian E. de Graaf, Andrey V. Danilov, A. A. Adamyan +1 more

We report on the design and performance of a cryogenic (300 mK) near-field scanning microwave microscope. It uses a microwave resonator as the near-field sensor, operating at a frequency of 6 GHz and microwave probing amplitudes down to 100 μV, approaching low enough photon population (N ∼ 1000) of the resonator such that coherent quantum manipulation becomes feasible. The resonator is made out of a miniaturized distributed fractal superconducting circuit that is integrated with the probing tip, micromachined to be compact enough such that it can be mounted directly on a quartz tuning-fork, and used for parallel operation as an atomic force microscope (AFM). The resonator is magnetically coupled to a transmission line for readout, and to achieve enhanced sensitivity we employ a Pound-Drever-Hall measurement scheme to lock to the resonance frequency. We achieve a well localized near-field around the tip such that the microwave resolution is comparable to the AFM resolution, and a capacitive sensitivity down to 6.4 × 10(-20) F/Hz, limited by mechanical noise. We believe that the results presented here are a significant step towards probing quantum systems at the nanoscale using near-field scanning microwave microscopy.

arXiv:1404.0534•Review of Scientific Instruments•Feb 1, 2013•33 citations

Radiative Cooling of a Superconducting Resonator

Mingrui Xu, Xu Han, Chang‐Ling Zou +5 more

Cooling microwave resonators to near the quantum ground state, crucial for their operation in the quantum regime, is typically achieved by direct device refrigeration to a few tens of millikelvin. However, in quantum experiments that require high operation power such as microwave-to-optics quantum transduction, it is desirable to operate at higher temperatures with non-negligible environmental thermal excitations, where larger cooling power is available. In this Letter, we present a radiative cooling protocol to prepare a superconducting microwave mode near its quantum ground state in spite of warm environment temperatures for the resonator. In this proof-of-concept experiment, the mode occupancy of a 10 GHz superconducting resonator thermally anchored at 1.02 K is reduced to 0.44±0.05 from 1.56 by radiatively coupling to a 70 mK cold load. This radiative cooling scheme allows high-operation-power microwave experiments to work in the quantum regime, and opens possibilities for routing microwave quantum states to elevated temperatures.

arXiv:1910.01203•Physical Review Letters•Jan 23, 2020•47 citations

A micro-SQUID with dispersive readout for magnetic scanning microscopy

F. Foroughi, J.-M. Mol, T. Müller +3 more

We have designed and characterized a micro-SQUID with dispersive readout for use in low temperature scanning probe microscopy systems. The design features a capacitively shunted RF SQUID with a tunable resonance frequency from 5 to 12 GHz, micrometer spatial resolution, and integrated superconducting coils for local application of magnetic fields. The SQUID is operated as a nonlinear oscillator with a flux- and power-dependent resonance frequency. Measurements for device characterization and noise benchmarking were carried out at 4 K. The measured flux noise above 10 kHz at 4 K is 80 nΦ0 Hz−1∕2 at a bandwidth of 200 MHz. Estimations suggest that one can benefit from parametric gain based on inherent nonlinearity of the Josephson junction and reduce the flux noise to 30 nΦ0Hz–1∕2 at 100 mK, which corresponds to 10.6 μBHz–1∕2 for a magnetic moment located at the center of the pickup loop.

arXiv:1803.07636•Applied Physics Letters•Jun 18, 2018•24 citations

Superconducting stripline resonators at frequencies up to 50 GHz for microwave spectroscopy applications

Tobias Wollandt, Markus Thiemann, Martin Dressel +1 more

Planar superconducting microwave resonators are commonly operated for various cryogenic applications, typically at frequencies between 2 and 15 GHz. But for certain applications, e.g. microwave spectroscopy to study the dynamics of charges and spins in solids, a wider spectral range is desired. Driving such microwave resonators at higher frequencies is challenging due to enhanced losses and reduced wavelength. Here we present superconducting stripline resonators operating at multiple frequencies as high as 50 GHz. These resonators are fabricated of Pb and can easily be adjusted to particular applications, including mK temperatures in a dilution refrigerator. Demonstrating such a resonator as a spectroscopic tool, we detect the superconducting transition of a Sn sample in a wide spectral range.

Journal of Physics Conference Series•Mar 1, 2018•0 citations

Magnetic field robust high quality factor NbTiN superconducting microwave resonators

Manuel Müller, Thomas Luschmann, A Faltermeier +13 more

Abstract We systematically study the performance of compact lumped element planar microwave Nb70Ti30N (NbTiN) resonators operating at 5 GHz in external in-plane magnetic fields up to 440 mT, a broad temperature regime from 2.2 K up to 13 K, as well as mK temperatures. For comparison, the resonators have been fabricated on thermally oxidized and pristine, (001) oriented silicon substrates. When operating the resonators in the multi-photon regime at T = 2.2 K, we find internal quality factors Q int ≃ 2 × 105 for NbTiN resonators grown on pristine Si substrates. In addition, we investigate the Q-factors of the resonators on pristine Si substrates at millikelvin temperatures to assess their applicability for quantum applications. We find Q int ≃ 2 × 105 in the single photon regime and Q int ≃ 5 × 105 in the high power regime at T = 7 mK. From the excellent performance of our resonators over a broad temperature and magnetic field range, we conclude that NbTiN deposited on Si (100) substrates, where the surface oxide has been removed, constitutes a promising material platform for electron spin resonance and ferromagnetic resonance experiments using superconducting planar microwave resonators.

arXiv:2112.08296•Materials for Quantum Technology•Feb 2, 2022•25 citations

Millikelvin Nb nanoSQUID-embedded tunable resonator fabricated with a neon focused-ion-beam

Jamie Potter, Laith Meti, Gemma Chapman +3 more

SQUID-embedded superconducting resonators are of great interest due to their potential for coupling highly scalable superconducting circuits with quantum memories based on solid-state spin ensembles. Such an application requires a high-Q, frequency-tunable resonator that is both resilient to magnetic field and able to operate at millikelvin temperatures. These requirements motivate the use of a higher Hc metal such as niobium; however, the challenge then becomes to sufficiently reduce the operating temperature. We address this by presenting a monolithic Nb nanoSQUID-embedded resonator, where neon focused-ion-beam fabrication of the nanoSQUID results in a device displaying frequency tunability at T=16 mK. In order to assess the applicability of the device for coupling to small spin clusters, we characterize the flux sensitivity as a function of microwave drive power and externally applied magnetic field and find that the noise is dominated by dielectric noise in the resonator. Finally, we discuss improvements to the device design that can dramatically improve the flux sensitivity, which highlights the promise of Nb SQUID-embedded resonators for hybrid superconductor-spin applications.

arXiv:2412.16045•Applied Physics Letters•Jan 3, 2025•6 citations
We have fabricated a superconducting resonator capable of generating a strong microwave magnetic field in a small (100 μm) volume for low temperature magnetic resonance experiments. While the resonator was specifically developed for use at millikelvin temperatures in a dilution refrigerator, where the total cooling power is limited to a few hundred microwatts, it is also useful at temperatures up to 5 K. The resonator consists of a 220 μm diameter, 2-1/2 turn niobium coil resonating with a short section of niobium microstripline. At a resonance frequency of 3 GHz, the loaded Q of the resonator was 780. The field strength was characterized by performing electron spin nutations. Operating at 100 mK with 320 μW of dissipated power, the resonator generated a field of 4 G at a distance of 100 μm from the coil.
We report on the design and performance of a cryogenic (300 mK) near-field scanning microwave microscope. It uses a microwave resonator as the near-field sensor, operating at a frequency of 6 GHz and microwave probing amplitudes down to 100 μV, approaching low enough photon population (N ∼ 1000) of the resonator such that coherent quantum manipulation becomes feasible. The resonator is made out of a miniaturized distributed fractal superconducting circuit that is integrated with the probing tip, micromachined to be compact enough such that it can be mounted directly on a quartz tuning-fork, and used for parallel operation as an atomic force microscope (AFM). The resonator is magnetically coupled to a transmission line for readout, and to achieve enhanced sensitivity we employ a Pound-Drever-Hall measurement scheme to lock to the resonance frequency. We achieve a well localized near-field around the tip such that the microwave resolution is comparable to the AFM resolution, and a capacitive sensitivity down to 6.4 × 10(-20) F/Hz, limited by mechanical noise. We believe that the results presented here are a significant step towards probing quantum systems at the nanoscale using near-field scanning microwave microscopy.
Cooling microwave resonators to near the quantum ground state, crucial for their operation in the quantum regime, is typically achieved by direct device refrigeration to a few tens of millikelvin. However, in quantum experiments that require high operation power such as microwave-to-optics quantum transduction, it is desirable to operate at higher temperatures with non-negligible environmental thermal excitations, where larger cooling power is available. In this Letter, we present a radiative cooling protocol to prepare a superconducting microwave mode near its quantum ground state in spite of warm environment temperatures for the resonator. In this proof-of-concept experiment, the mode occupancy of a 10 GHz superconducting resonator thermally anchored at 1.02 K is reduced to 0.44±0.05 from 1.56 by radiatively coupling to a 70 mK cold load. This radiative cooling scheme allows high-operation-power microwave experiments to work in the quantum regime, and opens possibilities for routing microwave quantum states to elevated temperatures.
We have designed and characterized a micro-SQUID with dispersive readout for use in low temperature scanning probe microscopy systems. The design features a capacitively shunted RF SQUID with a tunable resonance frequency from 5 to 12 GHz, micrometer spatial resolution, and integrated superconducting coils for local application of magnetic fields. The SQUID is operated as a nonlinear oscillator with a flux- and power-dependent resonance frequency. Measurements for device characterization and noise benchmarking were carried out at 4 K. The measured flux noise above 10 kHz at 4 K is 80 nΦ0 Hz−1∕2 at a bandwidth of 200 MHz. Estimations suggest that one can benefit from parametric gain based on inherent nonlinearity of the Josephson junction and reduce the flux noise to 30 nΦ0Hz–1∕2 at 100 mK, which corresponds to 10.6 μBHz–1∕2 for a magnetic moment located at the center of the pickup loop.
Planar superconducting microwave resonators are commonly operated for various cryogenic applications, typically at frequencies between 2 and 15 GHz. But for certain applications, e.g. microwave spectroscopy to study the dynamics of charges and spins in solids, a wider spectral range is desired. Driving such microwave resonators at higher frequencies is challenging due to enhanced losses and reduced wavelength. Here we present superconducting stripline resonators operating at multiple frequencies as high as 50 GHz. These resonators are fabricated of Pb and can easily be adjusted to particular applications, including mK temperatures in a dilution refrigerator. Demonstrating such a resonator as a spectroscopic tool, we detect the superconducting transition of a Sn sample in a wide spectral range.
Abstract We systematically study the performance of compact lumped element planar microwave Nb70Ti30N (NbTiN) resonators operating at 5 GHz in external in-plane magnetic fields up to 440 mT, a broad temperature regime from 2.2 K up to 13 K, as well as mK temperatures. For comparison, the resonators have been fabricated on thermally oxidized and pristine, (001) oriented silicon substrates. When operating the resonators in the multi-photon regime at T = 2.2 K, we find internal quality factors Q int ≃ 2 × 105 for NbTiN resonators grown on pristine Si substrates. In addition, we investigate the Q-factors of the resonators on pristine Si substrates at millikelvin temperatures to assess their applicability for quantum applications. We find Q int ≃ 2 × 105 in the single photon regime and Q int ≃ 5 × 105 in the high power regime at T = 7 mK. From the excellent performance of our resonators over a broad temperature and magnetic field range, we conclude that NbTiN deposited on Si (100) substrates, where the surface oxide has been removed, constitutes a promising material platform for electron spin resonance and ferromagnetic resonance experiments using superconducting planar microwave resonators.
SQUID-embedded superconducting resonators are of great interest due to their potential for coupling highly scalable superconducting circuits with quantum memories based on solid-state spin ensembles. Such an application requires a high-Q, frequency-tunable resonator that is both resilient to magnetic field and able to operate at millikelvin temperatures. These requirements motivate the use of a higher Hc metal such as niobium; however, the challenge then becomes to sufficiently reduce the operating temperature. We address this by presenting a monolithic Nb nanoSQUID-embedded resonator, where neon focused-ion-beam fabrication of the nanoSQUID results in a device displaying frequency tunability at T=16 mK. In order to assess the applicability of the device for coupling to small spin clusters, we characterize the flux sensitivity as a function of microwave drive power and externally applied magnetic field and find that the noise is dominated by dielectric noise in the resonator. Finally, we discuss improvements to the device design that can dramatically improve the flux sensitivity, which highlights the promise of Nb SQUID-embedded resonators for hybrid superconductor-spin applications.