Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1404.0534 · Review of Scientific Instruments

A near-field scanning microwave microscope based on a superconducting resonator for low power measurements

Sebastian E. de Graaf, Andrey V. Danilov, A. A. Adamyan, Sergey Kubatkin

Published Feb 1, 2013• 33 citations
arXivHTMLPDF

Abstract

We report on the design and performance of a cryogenic (300 mK) near-field scanning microwave microscope. It uses a microwave resonator as the near-field sensor, operating at a frequency of 6 GHz and microwave probing amplitudes down to 100 μV, approaching low enough photon population (N ∼ 1000) of the resonator such that coherent quantum manipulation becomes feasible. The resonator is made out of a miniaturized distributed fractal superconducting circuit that is integrated with the probing tip, micromachined to be compact enough such that it can be mounted directly on a quartz tuning-fork, and used for parallel operation as an atomic force microscope (AFM). The resonator is magnetically coupled to a transmission line for readout, and to achieve enhanced sensitivity we employ a Pound-Drever-Hall measurement scheme to lock to the resonance frequency. We achieve a well localized near-field around the tip such that the microwave resolution is comparable to the AFM resolution, and a capacitive sensitivity down to 6.4 × 10(-20) F/Hz, limited by mechanical noise. We believe that the results presented here are a significant step towards probing quantum systems at the nanoscale using near-field scanning microwave microscopy.

DOI
10.1063/1.4792381

Related papers

Fractal superconducting resonators for the interrogation of two-level systems

D. de Graaf, Sebastian Erik

In this thesis we use high-Q superconducting thin-film microwave resonators to interact with several types of quantum mechanical two-level systems. Such a resonator is used as the central building block in a cryogenic near-field scanning microwave microscope (NSMM) to reach a completely new regime of NSMM operation. In this regime where the superconducting resonator is only populated with a small number of photons, we demonstrate a capacitance sensitivity down to 64x10^(-21) Farad/rtHz and nanoscale resolution, which is sufficient to apply this scanning probe technique to quantum coherent objects. Such a 'coherent'-NSMM enables several new applications: for example to study the interaction of the NSMM probe with two-level defects in samples and to characterize artificial two-level systems (qubits), which eventually could lead to better understanding of decoherence mechanisms in superconducting quantum circuits. We demonstrate the ability to reach this regime in a sample consisting of a Cooper-pair box (CPB) weakly coupled to a superconducting resonator. In the strong driving regime we observe Landau-Zener-Stückelberg interference and we discover a new type of relaxation mechanism in the strongly driven CPBthat involves pair breaking and quasiparticle tunneling. It results in a recovered parity of the CPB and a population inversion of the dressed states. Not only does this demonstrate the applicability of NSMM for qubit characterization, but the quasiparticle mediated population inversion also becomes suitable for robust charge sensing in a scanning probe setup. To integrate the superconducting resonator onto our NSMM probe we develop a new type of resonator design - the fractal design - that have a very small external dipole moment allowing for a compact resonator. Another advantage of the fractal resonator is its resilience to magnetic fields. We show that the fractal resonator, after further optimization, can maintain quality factors above 10^5 in applied fields of more than 400 mT, something that becomes particularly useful for the interrogation of spin ensembles coupled to the resonator. We demonstrate that it is possible to detect down to 5x10^5 spins/rtHz in a very small volume coupled to a fractal resonator. Furthermore, the low dipole moment of the fractal resonator allows us to also introduce DC bias into the resonator without degrading its Q-factor. This is an important technological step that allows us to interact with new materials where spins can be quickly and locally manipulated using electric fields and we demonstrate the first steps in this direction with ensembles of manganese doped ZnO nanowires and frustrated molecular Cu spin triangles.The measurements achieve a very high sensitivity thanks to the Pound-Drever-Hall locking technique used. We develop this technique such that both resonance frequency and quality factor can be monitored with very high accuracy in real time. The demonstrated stability is ~30 Hz/rtHz for frequency readout and we can determine the Q-factor with a precision of 34 dB/rtHz.

•Jan 1, 2014•1 citation

Coherent interaction with two-level fluctuators using near field scanning microwave microscopy

Sebastian E. de Graaf, Andrey V. Danilov, Sergey Kubatkin

Near field Scanning Microwave Microscopy (NSMM) is a scanning probe technique that non-invasively can obtain material properties on the nano-scale at microwave frequencies. While focus has been on developing room-temperature systems it was recently shown that this technique can potentially reach the quantum regime, opening up for applications in materials science and device characterization in solid state quantum information processing. In this paper we theoretically investigate this new regime of NSMM. Specifically we show that interaction between a resonant NSMM probe and certain types of two-level systems become possible when the NSMM probe operates in the (sub-) single photon regime, and we expect a high signal-to-noise ratio if operated under the right conditions. This would allow to detect single atomic material defects with energy splittings in the GHz range with nano-scale resolution, provided that individual defects in the material under study are well enough separated. We estimate that this condition is fulfilled for materials with loss tangents below tan δ ∼ 10(-3) which holds for materials used in today's quantum circuits and devices where typically tan δ < 10(-5). We also propose several extensions to a resonant NSMM that could improve sensitivity and functionality also for microscopes operating in a high power regime.

Scientific Reports•Nov 24, 2015•11 citations

Microwave near-field imaging of electric fields in a superconducting microstrip resonator

Ashfaq S. Thanawalla, S. K. Dutta, C. P. Vlahacos +5 more

We describe the use of a cryogenic near-field scanning microwave microscope to image microwave electric fields from superconducting and normal-metal microstrip resonators. The microscope employs an open-ended coaxial probe and operates from 77 to 300 K in the 0.01–20 GHz frequency range with a spatial resolution of about 200 μm. We describe the operation of the system and present microwave images of Cu and Tl2Ba2CaCu2O8 microstrip resonators, showing standing wave patterns at the fundamental and second harmonic frequencies.

arXiv:cond-mat/9805239•Applied Physics Letters•Oct 26, 1998•25 citations

A micro-SQUID with dispersive readout for magnetic scanning microscopy

F. Foroughi, J.-M. Mol, T. Müller +3 more

We have designed and characterized a micro-SQUID with dispersive readout for use in low temperature scanning probe microscopy systems. The design features a capacitively shunted RF SQUID with a tunable resonance frequency from 5 to 12 GHz, micrometer spatial resolution, and integrated superconducting coils for local application of magnetic fields. The SQUID is operated as a nonlinear oscillator with a flux- and power-dependent resonance frequency. Measurements for device characterization and noise benchmarking were carried out at 4 K. The measured flux noise above 10 kHz at 4 K is 80 nΦ0 Hz−1∕2 at a bandwidth of 200 MHz. Estimations suggest that one can benefit from parametric gain based on inherent nonlinearity of the Josephson junction and reduce the flux noise to 30 nΦ0Hz–1∕2 at 100 mK, which corresponds to 10.6 μBHz–1∕2 for a magnetic moment located at the center of the pickup loop.

arXiv:1803.07636•Applied Physics Letters•Jun 18, 2018•24 citations

Scanning-Probe Quantum Sensing of a Microwave and Static Magnetic Field Response of an On-Chip Superconducting Resonator

Senlei Li, Jingcheng Zhou, 熊泽龙 +2 more

Superconducting resonators are finding increasing applications in designing advanced quantum circuits for an ongoing sensing, metrology, and computing technological revolution. A detailed knowledge of the microscopic electromagnetic properties of superconducting resonators is directly relevant for their further improvements on circuitry design and device performance. Here, we introduce scanning-probe quantum microscopy to report nanoscale sensing of the microwave and static magnetic field environment of an on-chip niobium (Nb) superconducting resonator. Taking advantage of Rabi oscillation measurements, we show that microwave magnetic fields generated by the superconducting resonator mode can be utilized to achieve coherent control of a quantum spin sensor. We further visualize the static electromagnetic field response of the Nb resonator, showing magnetic field-induced formation, evolution, and depinning of superconducting vortices. Our results provide insights into future design, testing, and evaluation of solid-state superconducting resonators, highlighting the potential of quantum sensors as a local probe to investigate electromagnetic properties of superconducting quantum circuits.

arXiv:2606.20904•Nano Letters•Aug 7, 2026•1 citation

Ultra-broadband near-field Josephson microwave microscopy

Ping Zhang, Yang-Yang Lyu, Jingjing Lv +15 more

Advanced microwave technologies constitute the foundation of a wide range of modern sciences, including microwave integrated circuits, quantum computing, microwave photonics, spintronics, etc. To facilitate the design of chip-based microwave devices, there is an increasing demand for state-of-the-art microscopic techniques that are capable of characterizing near-field microwave distribution and performance. In this work, we integrate Josephson junctions onto a nanosized quartz tip, forming a highly sensitive microwave mixer on-tip. This allows us to conduct spectroscopic imaging of near-field microwave distributions with high spatial resolution. By leveraging its microwave-sensitive characteristics, our Josephson microscopy achieves a broad detecting bandwidth of ≤200 GHz, as well as remarkable frequency and intensity resolutions. Near-field characterizations of microwave circuits are also conducted to demonstrate the capabilities of Josephson microscopy. Our work emphasizes the benefits of utilizing Josephson microscopy as a real-time, non-destructive technique to advance integrated microwave devices.

arXiv:2401.12545•National Science Review•Sep 3, 2024•8 citations
We report on the design and performance of a cryogenic (300 mK) near-field scanning microwave microscope. It uses a microwave resonator as the near-field sensor, operating at a frequency of 6 GHz and microwave probing amplitudes down to 100 μV, approaching low enough photon population (N ∼ 1000) of the resonator such that coherent quantum manipulation becomes feasible. The resonator is made out of a miniaturized distributed fractal superconducting circuit that is integrated with the probing tip, micromachined to be compact enough such that it can be mounted directly on a quartz tuning-fork, and used for parallel operation as an atomic force microscope (AFM). The resonator is magnetically coupled to a transmission line for readout, and to achieve enhanced sensitivity we employ a Pound-Drever-Hall measurement scheme to lock to the resonance frequency. We achieve a well localized near-field around the tip such that the microwave resolution is comparable to the AFM resolution, and a capacitive sensitivity down to 6.4 × 10(-20) F/Hz, limited by mechanical noise. We believe that the results presented here are a significant step towards probing quantum systems at the nanoscale using near-field scanning microwave microscopy.
In this thesis we use high-Q superconducting thin-film microwave resonators to interact with several types of quantum mechanical two-level systems. Such a resonator is used as the central building block in a cryogenic near-field scanning microwave microscope (NSMM) to reach a completely new regime of NSMM operation. In this regime where the superconducting resonator is only populated with a small number of photons, we demonstrate a capacitance sensitivity down to 64x10^(-21) Farad/rtHz and nanoscale resolution, which is sufficient to apply this scanning probe technique to quantum coherent objects. Such a 'coherent'-NSMM enables several new applications: for example to study the interaction of the NSMM probe with two-level defects in samples and to characterize artificial two-level systems (qubits), which eventually could lead to better understanding of decoherence mechanisms in superconducting quantum circuits. We demonstrate the ability to reach this regime in a sample consisting of a Cooper-pair box (CPB) weakly coupled to a superconducting resonator. In the strong driving regime we observe Landau-Zener-Stückelberg interference and we discover a new type of relaxation mechanism in the strongly driven CPBthat involves pair breaking and quasiparticle tunneling. It results in a recovered parity of the CPB and a population inversion of the dressed states. Not only does this demonstrate the applicability of NSMM for qubit characterization, but the quasiparticle mediated population inversion also becomes suitable for robust charge sensing in a scanning probe setup. To integrate the superconducting resonator onto our NSMM probe we develop a new type of resonator design - the fractal design - that have a very small external dipole moment allowing for a compact resonator. Another advantage of the fractal resonator is its resilience to magnetic fields. We show that the fractal resonator, after further optimization, can maintain quality factors above 10^5 in applied fields of more than 400 mT, something that becomes particularly useful for the interrogation of spin ensembles coupled to the resonator. We demonstrate that it is possible to detect down to 5x10^5 spins/rtHz in a very small volume coupled to a fractal resonator. Furthermore, the low dipole moment of the fractal resonator allows us to also introduce DC bias into the resonator without degrading its Q-factor. This is an important technological step that allows us to interact with new materials where spins can be quickly and locally manipulated using electric fields and we demonstrate the first steps in this direction with ensembles of manganese doped ZnO nanowires and frustrated molecular Cu spin triangles.The measurements achieve a very high sensitivity thanks to the Pound-Drever-Hall locking technique used. We develop this technique such that both resonance frequency and quality factor can be monitored with very high accuracy in real time. The demonstrated stability is ~30 Hz/rtHz for frequency readout and we can determine the Q-factor with a precision of 34 dB/rtHz.
Near field Scanning Microwave Microscopy (NSMM) is a scanning probe technique that non-invasively can obtain material properties on the nano-scale at microwave frequencies. While focus has been on developing room-temperature systems it was recently shown that this technique can potentially reach the quantum regime, opening up for applications in materials science and device characterization in solid state quantum information processing. In this paper we theoretically investigate this new regime of NSMM. Specifically we show that interaction between a resonant NSMM probe and certain types of two-level systems become possible when the NSMM probe operates in the (sub-) single photon regime, and we expect a high signal-to-noise ratio if operated under the right conditions. This would allow to detect single atomic material defects with energy splittings in the GHz range with nano-scale resolution, provided that individual defects in the material under study are well enough separated. We estimate that this condition is fulfilled for materials with loss tangents below tan δ ∼ 10(-3) which holds for materials used in today's quantum circuits and devices where typically tan δ < 10(-5). We also propose several extensions to a resonant NSMM that could improve sensitivity and functionality also for microscopes operating in a high power regime.
We describe the use of a cryogenic near-field scanning microwave microscope to image microwave electric fields from superconducting and normal-metal microstrip resonators. The microscope employs an open-ended coaxial probe and operates from 77 to 300 K in the 0.01–20 GHz frequency range with a spatial resolution of about 200 μm. We describe the operation of the system and present microwave images of Cu and Tl2Ba2CaCu2O8 microstrip resonators, showing standing wave patterns at the fundamental and second harmonic frequencies.
We have designed and characterized a micro-SQUID with dispersive readout for use in low temperature scanning probe microscopy systems. The design features a capacitively shunted RF SQUID with a tunable resonance frequency from 5 to 12 GHz, micrometer spatial resolution, and integrated superconducting coils for local application of magnetic fields. The SQUID is operated as a nonlinear oscillator with a flux- and power-dependent resonance frequency. Measurements for device characterization and noise benchmarking were carried out at 4 K. The measured flux noise above 10 kHz at 4 K is 80 nΦ0 Hz−1∕2 at a bandwidth of 200 MHz. Estimations suggest that one can benefit from parametric gain based on inherent nonlinearity of the Josephson junction and reduce the flux noise to 30 nΦ0Hz–1∕2 at 100 mK, which corresponds to 10.6 μBHz–1∕2 for a magnetic moment located at the center of the pickup loop.
Superconducting resonators are finding increasing applications in designing advanced quantum circuits for an ongoing sensing, metrology, and computing technological revolution. A detailed knowledge of the microscopic electromagnetic properties of superconducting resonators is directly relevant for their further improvements on circuitry design and device performance. Here, we introduce scanning-probe quantum microscopy to report nanoscale sensing of the microwave and static magnetic field environment of an on-chip niobium (Nb) superconducting resonator. Taking advantage of Rabi oscillation measurements, we show that microwave magnetic fields generated by the superconducting resonator mode can be utilized to achieve coherent control of a quantum spin sensor. We further visualize the static electromagnetic field response of the Nb resonator, showing magnetic field-induced formation, evolution, and depinning of superconducting vortices. Our results provide insights into future design, testing, and evaluation of solid-state superconducting resonators, highlighting the potential of quantum sensors as a local probe to investigate electromagnetic properties of superconducting quantum circuits.
Advanced microwave technologies constitute the foundation of a wide range of modern sciences, including microwave integrated circuits, quantum computing, microwave photonics, spintronics, etc. To facilitate the design of chip-based microwave devices, there is an increasing demand for state-of-the-art microscopic techniques that are capable of characterizing near-field microwave distribution and performance. In this work, we integrate Josephson junctions onto a nanosized quartz tip, forming a highly sensitive microwave mixer on-tip. This allows us to conduct spectroscopic imaging of near-field microwave distributions with high spatial resolution. By leveraging its microwave-sensitive characteristics, our Josephson microscopy achieves a broad detecting bandwidth of ≤200 GHz, as well as remarkable frequency and intensity resolutions. Near-field characterizations of microwave circuits are also conducted to demonstrate the capabilities of Josephson microscopy. Our work emphasizes the benefits of utilizing Josephson microscopy as a real-time, non-destructive technique to advance integrated microwave devices.