Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE

High-efficiency laser-pumping system for magnetic resonance imaging

Marziale Milani, Guido Baroni, Lorenzo Ferraro, Piero Sozzani, Massimo Adobati, S. Ravetta

Published May 3, 2000• 1 citation
Publisher

Abstract

Recently the demand for hyperpolarized noble gases is arising to improve NMR spectroscopy resolution for imaging. Hyperpolarization of noble gases is achieved by spin- exchange with alkali metal. atoms that undergo optical pumping by circularly polarized radiation. Optical pumping is usually achieved by high power semiconductor lasers. These sources have a bandwidth very large when compared with the transition bandwidth of the optically active species. This has two serious consequences: (i) the request of high power lasers, (ii) the losses that the unemployed energy delivered to the Rb vapor can provide in the efficiency of the energy transfer. Object of our investigation will be the comparison of two experimental set ups for optical pumping of Rb vapor where pumping is given in one case by a dye laser pumped by a UV nitrogen laser built in our laboratory according to the Blumlein scheme and in the other case by a semiconductor laser. Major elements that will be discussed are (1) the role of stimulated emission of Rb vapor to increase the pumping efficiency, (2) the fate of resonant photons that are emitted during Rb decays, (3) the role of applied magnetic fields in the efficiency of pumping processes.

DOI
10.1117/12.384902

Related papers

Production of Hyperpolarized 129Xe Using Spin Exchange Optical Pumping

Vladimir Vladimirovich Kavtanyuk, Wooyoung Kim, Yu Ando +3 more

We present a constructed setup for polarizing 129 Xe noble gas. Hyperpolarized 129 Xe has been obtained via spin exchange with an optically pumped rubidium vapor. Optical pumping is based on polarizing the valence electron of rubidium by the resonant absorption of a circularly polarized laser light. The magnetic field of 30 G was used for obtaining 129 Xe polarization. The apparatus for detecting polarization is a nuclear magnetic resonance spectrometer. The highest 129 Xe polarization of 54% has been obtained using 60 W circularly polarized laser light with wavelength of 794.7 nm. The measured longitudinal relaxation time of the hyperpolarized 129 Xe was 72.3 minutes.

Journal of the Korean Physical Society•Nov 1, 2018•1 citation

The xenon hyperpolarization by alexandrite laser spin exchange optical pumping

A. G. Putilov, А. А. Антипов, Alexandr Shepelev

This paper shows the possibility of the use of a solid-state alexandrite laser as a radiation source for the method of spin-exchange optical pumping of noble gases (xenon, krypton). The use of dispersive optical elements in the laser cavity will allows the adjusting of the radiation wavelength exactly in the rubidium spectral absorption lines 794.7 nm and 780 nm. To obtain a hyperpolarized state of noble gases, it is necessary to excite rubidium atoms for further spin-exchange process with the noble gas nuclei. This fact will allow the increasing of the magnetic resonance imaging contrast in the field of diagnosis of respiratory organs diseases.

EPJ Web of Conferences•Jan 1, 2019•3 citations

Xe 129 -Rb Spin-Exchange Optical Pumping with High Photon Efficiency

Graham Norquay, Guilhem J. Collier, Madhwesha R. Rao +2 more

Here we present a $\mathrm{Rb}\text{\ensuremath{-}}^{129}\mathrm{Xe}$ spin-exchange optical pumping polarizer capable of rapid generation of large volumes of highly polarized $^{129}\mathrm{Xe}$ gas. Through modeling and measurements we maximize the $^{129}\mathrm{Xe}$ nuclear spin polarization output to enable the generation of polarized $^{129}\mathrm{Xe}$ gas imaging volumes ($300\text{ }\text{ }{\mathrm{cm}}^{3}$) every 5 min within a clinical setting. Our model is verified by experiment to correctly predict the optimum Rb vapor density for maximum $^{129}\mathrm{Xe}$ nuclear polarization for a flux $3.4\text{ }\text{ }\mathrm{W}/{\mathrm{cm}}^{2}$ of circularly polarized Rb ${D}_{1}$ photons incident on an 80 cm long cylindrical optical cell. We measure a $^{129}\mathrm{Xe}$ magnetization production efficiency of ${\ensuremath{\eta}}_{\mathrm{pr}}=1.8%$, which approaches the photon efficiency limit ${\ensuremath{\eta}}_{\ensuremath{\gamma}}=3.3%$ of this system and enables the polarization of $2.72\ifmmode\times\else\texttimes\fi{}{10}^{22}$ $^{129}\mathrm{Xe}$ spins per hour, corresponding to $1013\text{ }\text{ }{\mathrm{cm}}^{3}$ of 100% polarized $^{129}\mathrm{Xe}$ at STP. This magnetization production rate is threefold higher than the highest previously published $^{129}\mathrm{Xe}$ magnetization production rate and has enabled routine clinical lung magnetic resonance imaging (MRI) with hyperpolarized $^{129}\mathrm{Xe}$ doses available on demand at run time, as well as high-SNR $^{129}\mathrm{Xe}$ MRI of the human brain and kidneys.

Physical Review Letters•Oct 8, 2018•99 citations

Synchronous Spin-Exchange Optical Pumping

Anna Korver, Daniel Thrasher, Michael Bulatowicz +1 more

We demonstrate a new approach to precision NMR with hyperpolarized gases designed to mitigate NMR shifts due to the alkali spin-exchange field. The NMR bias field is implemented as a sequence of alkali (Rb) 2π pulses, allowing the Rb polarization to be optically pumped transverse to the bias field. When the Rb polarization is modulated at the noble-gas (Xe) NMR resonance, spin-exchange collisions buildup a precessing transverse Xe polarization. We study and mitigate novel NMR broadening effects due to the oscillating spin-exchange field. Spin-exchange frequency shifts are suppressed 2500×, and Rb magnetometer gain measurements project photon shot-noise limited NMR frequency uncertainties below 10 nHz/sqrt[Hz].

arXiv:1506.08797•Physical Review Letters•Dec 18, 2015•64 citations

Spin-exchange optical pumping of noble-gas nuclei

Thad G Walker, W. Happer

Spin-exchange optical pumping of mixtures of alkali-metal vapors and noble gases can be used to efficiently polarize the nuclei of the noble-gas atoms. Liters of noble gases at standard temperature and pressure and with nuclear spin polarizations of several tens of percent are now used in many applications. The authors describe the basic phenomena that govern the spin-exchange process and review the physics of angular momentum transfer and loss in optical pumping and spin-exchange collisions.

Reviews of Modern Physics•Apr 1, 1997•1,475 citations

An Interferometric Technique Of Density Measurement Applied To Alkali-metal Vapors Oriented By Optical Pumping.

Steven Jarrett

III-8.Comparison of optical pumping signals for two spherical cells with different buffer gas pressures as a function of density times diameter of cell for equal D2/D1.60 IV-1.Energy level diagram showing hyperfine structure of Rb Di line.Units are 10*3 cm-1.67 IV-2.Equivalent circuit for rate equations involving ex change polarization.73 IV-3.Diagram of optical system for optical pumping of Rb. 83 IV-4.Block diagram of Rb optical pumping signal detection system.85 IV-5.Block diagram of Rb light detection system.90 IV-6.Typical photograph from which relaxation time measure ments are made..Time increases from left to right.Scale is 1 millisecond per division.92 IV-7.Lines determined from measurements on time dependence of Rb87 signals at 50°C for the two different light in tensities.Scatter of points is too small to be notice able on graph.93 A-1.Spectral profile of D1 radiation from a Varian spectral lamp containing natural Rb.Ill A-2.Spectral profile of Di radiation from a Varian spectral lamp containing Rb87.112 A-3-Spectral profile of Di radiation from a Varian spectral lamp containing Rb87 after filtering by an Rb85 absorption cell.113 vi CHAPTER I2 atomic ground states and the parameters of various relaxation processes of gaseous systems.These investigations led to the development of mag netometers of unique sensitivity.More recently, very precise frequency standards have been developed using the methods of optical pumping and the knowledge gained through their application.The present work was undertaken in the context of extending our knowledge of the dynamics of optical pumping methods and of exploiting these methods for the deter mination of an interesting atomic exchange cross section.Optical pumping may be considered as a specialized technique used in conjunction with magnetic resonance phenomena.All magnetic reso nance techniques depend upon obtaining an oriented (polarized) macro scopic sample of matter, that is, matter with a net magnetic moment.In the atomic beam magnetic resonance method, this is accomplished by sort ing out, spatially, atoms whose magnetic moments have a particular ori entation with respect to a magnetic field.In nuclear or electron para magnetic resonance work in solids, liquids, or gases, the small thermal equilibrium polarization that matter possesses in a magnetic field is exploited.Optical pumping enhances this equilibrium polarization through selective optical absorption, by a gaseous atomic system, of polarized resonance radiation.Optical pumping offers the great advan tage of experimental simplicity, as compared to other magnetic resonance techniques, but suffers from severe limitations in application.Since the original suggestion by Brossel and Nastier^ and subse quent development by many others, optical pumping, in conjunction with the transmission monitoring technique of signal detection, has became a standard technique in the study of alkali metal ground states.By far the greatest amount of work in optical pumping has been concerned with alkali metal vapors.Bell, Bloom/ and others^ have considered the process of the optical pumping of the alkalis with attention to the spec tral composition of the pumping light, that is, the resonance radiation incident on the alkali vapor.Colegrove and Franken? have recently dis cussed the complication in the analyses of optical pumping signals for Q helium when the helium absorption cell is optically thick.Hobart has considered this same complication for sodium.Prediction of signals must take into account the fact that the pumping light is absorbed ap proximately exponentially in the optical pumping absorption cell.This means that the absorption coefficient, which is proportional to the al kali density, times the length of the cell is a significant parameter in determining the strength of the signal.Similar calculations of the dependence of optical pumping signals on alkali density and spectral com position of the pumping light will be presented in this work.In order to test the signal predictions> a high resolution Fabry-Perot spectrometer was constructed.This instrument can be used for two purposes : the investigation of the intensity distribution of the pumping light, and, more importantly, determinations of the alkali vapor density in the absorption cell.The desired data are curves of optical pumping signals, for a typical sodium optical pumping experiment, as a function of density.It is often necessary to know these densities in order to is limited to the accuracy to which the density is known.Since the Fabry-Perot spectrometer used to measure sodium vapor densities in conjunction with the signal strength versus density meas urements can be applied to different systems, it was decided to make a determination of the rubidium 85-rubidium 87 spin exchange cross sec tion.The reasons for this choice are discussed in detail in Chapt.IV.In brief, work on rubidium exchange offered some experimental sim plifications and rubidium has previously been studied more thoroughly than other systems.

•Jan 1, 1963•0 citations
Recently the demand for hyperpolarized noble gases is arising to improve NMR spectroscopy resolution for imaging. Hyperpolarization of noble gases is achieved by spin- exchange with alkali metal. atoms that undergo optical pumping by circularly polarized radiation. Optical pumping is usually achieved by high power semiconductor lasers. These sources have a bandwidth very large when compared with the transition bandwidth of the optically active species. This has two serious consequences: (i) the request of high power lasers, (ii) the losses that the unemployed energy delivered to the Rb vapor can provide in the efficiency of the energy transfer. Object of our investigation will be the comparison of two experimental set ups for optical pumping of Rb vapor where pumping is given in one case by a dye laser pumped by a UV nitrogen laser built in our laboratory according to the Blumlein scheme and in the other case by a semiconductor laser. Major elements that will be discussed are (1) the role of stimulated emission of Rb vapor to increase the pumping efficiency, (2) the fate of resonant photons that are emitted during Rb decays, (3) the role of applied magnetic fields in the efficiency of pumping processes.
We present a constructed setup for polarizing 129 Xe noble gas. Hyperpolarized 129 Xe has been obtained via spin exchange with an optically pumped rubidium vapor. Optical pumping is based on polarizing the valence electron of rubidium by the resonant absorption of a circularly polarized laser light. The magnetic field of 30 G was used for obtaining 129 Xe polarization. The apparatus for detecting polarization is a nuclear magnetic resonance spectrometer. The highest 129 Xe polarization of 54% has been obtained using 60 W circularly polarized laser light with wavelength of 794.7 nm. The measured longitudinal relaxation time of the hyperpolarized 129 Xe was 72.3 minutes.
This paper shows the possibility of the use of a solid-state alexandrite laser as a radiation source for the method of spin-exchange optical pumping of noble gases (xenon, krypton). The use of dispersive optical elements in the laser cavity will allows the adjusting of the radiation wavelength exactly in the rubidium spectral absorption lines 794.7 nm and 780 nm. To obtain a hyperpolarized state of noble gases, it is necessary to excite rubidium atoms for further spin-exchange process with the noble gas nuclei. This fact will allow the increasing of the magnetic resonance imaging contrast in the field of diagnosis of respiratory organs diseases.
Here we present a $\mathrm{Rb}\text{\ensuremath{-}}^{129}\mathrm{Xe}$ spin-exchange optical pumping polarizer capable of rapid generation of large volumes of highly polarized 129Xe^{129}\mathrm{Xe}129Xe gas. Through modeling and measurements we maximize the 129Xe^{129}\mathrm{Xe}129Xe nuclear spin polarization output to enable the generation of polarized 129Xe^{129}\mathrm{Xe}129Xe gas imaging volumes (300  cm3300\text{ }\text{ }{\mathrm{cm}}^{3}300  cm3) every 5 min within a clinical setting. Our model is verified by experiment to correctly predict the optimum Rb vapor density for maximum 129Xe^{129}\mathrm{Xe}129Xe nuclear polarization for a flux 3.4  W/cm23.4\text{ }\text{ }\mathrm{W}/{\mathrm{cm}}^{2}3.4  W/cm2 of circularly polarized Rb D1{D}_{1}D1​ photons incident on an 80 cm long cylindrical optical cell. We measure a 129Xe^{129}\mathrm{Xe}129Xe magnetization production efficiency of ${\ensuremath{\eta}}_{\mathrm{pr}}=1.8%$, which approaches the photon efficiency limit ${\ensuremath{\eta}}_{\ensuremath{\gamma}}=3.3%$ of this system and enables the polarization of $2.72\ifmmode\times\else\texttimes\fi{}{10}^{22}$ 129Xe^{129}\mathrm{Xe}129Xe spins per hour, corresponding to 1013  cm31013\text{ }\text{ }{\mathrm{cm}}^{3}1013  cm3 of 100% polarized 129Xe^{129}\mathrm{Xe}129Xe at STP. This magnetization production rate is threefold higher than the highest previously published 129Xe^{129}\mathrm{Xe}129Xe magnetization production rate and has enabled routine clinical lung magnetic resonance imaging (MRI) with hyperpolarized 129Xe^{129}\mathrm{Xe}129Xe doses available on demand at run time, as well as high-SNR 129Xe^{129}\mathrm{Xe}129Xe MRI of the human brain and kidneys.
We demonstrate a new approach to precision NMR with hyperpolarized gases designed to mitigate NMR shifts due to the alkali spin-exchange field. The NMR bias field is implemented as a sequence of alkali (Rb) 2π pulses, allowing the Rb polarization to be optically pumped transverse to the bias field. When the Rb polarization is modulated at the noble-gas (Xe) NMR resonance, spin-exchange collisions buildup a precessing transverse Xe polarization. We study and mitigate novel NMR broadening effects due to the oscillating spin-exchange field. Spin-exchange frequency shifts are suppressed 2500×, and Rb magnetometer gain measurements project photon shot-noise limited NMR frequency uncertainties below 10 nHz/sqrt[Hz].
III-8.Comparison of optical pumping signals for two spherical cells with different buffer gas pressures as a function of density times diameter of cell for equal D2/D1.60 IV-1.Energy level diagram showing hyperfine structure of Rb Di line.Units are 10*3 cm-1.67 IV-2.Equivalent circuit for rate equations involving ex change polarization.73 IV-3.Diagram of optical system for optical pumping of Rb. 83 IV-4.Block diagram of Rb optical pumping signal detection system.85 IV-5.Block diagram of Rb light detection system.90 IV-6.Typical photograph from which relaxation time measure ments are made..Time increases from left to right.Scale is 1 millisecond per division.92 IV-7.Lines determined from measurements on time dependence of Rb87 signals at 50°C for the two different light in tensities.Scatter of points is too small to be notice able on graph.93 A-1.Spectral profile of D1 radiation from a Varian spectral lamp containing natural Rb.Ill A-2.Spectral profile of Di radiation from a Varian spectral lamp containing Rb87.112 A-3-Spectral profile of Di radiation from a Varian spectral lamp containing Rb87 after filtering by an Rb85 absorption cell.113 vi CHAPTER I2 atomic ground states and the parameters of various relaxation processes of gaseous systems.These investigations led to the development of mag netometers of unique sensitivity.More recently, very precise frequency standards have been developed using the methods of optical pumping and the knowledge gained through their application.The present work was undertaken in the context of extending our knowledge of the dynamics of optical pumping methods and of exploiting these methods for the deter mination of an interesting atomic exchange cross section.Optical pumping may be considered as a specialized technique used in conjunction with magnetic resonance phenomena.All magnetic reso nance techniques depend upon obtaining an oriented (polarized) macro scopic sample of matter, that is, matter with a net magnetic moment.In the atomic beam magnetic resonance method, this is accomplished by sort ing out, spatially, atoms whose magnetic moments have a particular ori entation with respect to a magnetic field.In nuclear or electron para magnetic resonance work in solids, liquids, or gases, the small thermal equilibrium polarization that matter possesses in a magnetic field is exploited.Optical pumping enhances this equilibrium polarization through selective optical absorption, by a gaseous atomic system, of polarized resonance radiation.Optical pumping offers the great advan tage of experimental simplicity, as compared to other magnetic resonance techniques, but suffers from severe limitations in application.Since the original suggestion by Brossel and Nastier^ and subse quent development by many others, optical pumping, in conjunction with the transmission monitoring technique of signal detection, has became a standard technique in the study of alkali metal ground states.By far the greatest amount of work in optical pumping has been concerned with alkali metal vapors.Bell, Bloom/ and others^ have considered the process of the optical pumping of the alkalis with attention to the spec tral composition of the pumping light, that is, the resonance radiation incident on the alkali vapor.Colegrove and Franken? have recently dis cussed the complication in the analyses of optical pumping signals for Q helium when the helium absorption cell is optically thick.Hobart has considered this same complication for sodium.Prediction of signals must take into account the fact that the pumping light is absorbed ap proximately exponentially in the optical pumping absorption cell.This means that the absorption coefficient, which is proportional to the al kali density, times the length of the cell is a significant parameter in determining the strength of the signal.Similar calculations of the dependence of optical pumping signals on alkali density and spectral com position of the pumping light will be presented in this work.In order to test the signal predictions> a high resolution Fabry-Perot spectrometer was constructed.This instrument can be used for two purposes : the investigation of the intensity distribution of the pumping light, and, more importantly, determinations of the alkali vapor density in the absorption cell.The desired data are curves of optical pumping signals, for a typical sodium optical pumping experiment, as a function of density.It is often necessary to know these densities in order to is limited to the accuracy to which the density is known.Since the Fabry-Perot spectrometer used to measure sodium vapor densities in conjunction with the signal strength versus density meas urements can be applied to different systems, it was decided to make a determination of the rubidium 85-rubidium 87 spin exchange cross sec tion.The reasons for this choice are discussed in detail in Chapt.IV.In brief, work on rubidium exchange offered some experimental sim plifications and rubidium has previously been studied more thoroughly than other systems.