Physical Review A

Heliumlike geonium atom

Ana María Guerra Martins

Published Jul 2, 2001• 1 citation
Publisher

Abstract

We study the quantum dynamics of two interacting electrons confined in a Penning trap. We determine the characteristic frequencies of this system and we propose a way to perform measurement on spin and cyclotron degrees of freedom as well as a way of preparing the geonium atom in any spin state.
DOI
10.1103/physreva.64.023407

Related papers

Axial, magnetron, cyclotron and spin-cyclotron-beat frequencies measured on single electron almost at rest in free space (geonium)

Robert S. Van Dyck, Philip A. Ekstrom, HANS G. DEHMELT

Nature•Aug 26, 1976•53 citations

Experiments with an isolated subatomic particle at rest

HANS G. DEHMELT

Research begun in the early seventies on geonium is reviewed. Geonium is a man-made atom, created at liquid helium temperature in ultrahigh vacuum from an individual electron in magnetic and electric trapping fields.

Annual Meeting Optical Society of America•Jan 1, 1990•5 citations

The Geonium Chip: engineering a scalable planar Penningtrap

Jonathan Pinder

In this thesis is presented the realisation of `The Geonium Chip', a novel planar Penning trap. The chip is designed with the goal of building a truly scalable planar Penning trap, while retaining the accuracy of 3D traps. Manufactured with conventional metalon- silicon microfabrication techniques, the chip takes the 5 electrodes of the compensated cylindrical trap and projects them onto a ground-plane surface, thus forming the basis for its layout by reducing the electrode shape to an array of at rectangular surfaces. In this thesis I describe the conception, design and construction of a full cryogenic set-up, including the magnetics, for trapping and observing a single electron in the Geonium Chip Penning trap. The cyclotron mode of the trapped electron lies in the microwave regime, and thus the Geonium Chip has the potential to become a powerful building block for quantum microwave circuits, with coherent coupling to the cyclotron degree of freedom. This will also allow non-destructive measurement and interaction with the spin state of the electron. The development of the experimental process is detailed from scratch including the design, fabrication, and testing of the Geonium Chip, as well as the design, fabrication and testing of the experimental apparatus. The original solutions and space saving designs developed as part of the construction process are detailed, such as the custom on-chip cryogenic vacuum chamber, planar magnetic field source, and the LED-based electron loading system. The vacuum chamber and control systems are also described, and the in-house manufacturing capabilities of the Geonium group are detailed at length, with an emphasis on rapid prototyping high-accuracy components suitable for experimental use. The apparatus built within this PhD is within a few weeks of performing the first loading of electrons into the chip trap.

•Feb 21, 2017•4 citations

Direct observation of a single proton in a Penning trap. Towards a direct measurement of the proton g-factor

S. Kreim

This PhD thesis presents experiments performed on a single proton stored in a Penning trap. The eigenmotion of an isolated, free proton could be detected electronically via a coupling to a resonance circuit. This represents a non-destructive measurement, i. e. the particle is not lost during the measurement. The free cyclotron frequency emerging from the measured eigenfrequencies is one of the two frequencies required for the determination of the magnetic moment. This enables a direct determination of the g-factor contrary to already existing works. Design, developing, and commissioning of the experimental setup have been accomplished within the scope of this work leading to a measuring accuracy of 10−7. The technical challenges for the determination of the second frequency (the Larmor frequency) arising from the smallness of the magnetic moment were mastered. Since the spin state required for this measurement is an internal degree of freedom, it can only be accessed through a coupling of the magnetic moment to the eigenmotion. A novel, hybrid penning trap is presented in this work, which imprints the spin information onto the eigenmotion, thus, realizing a quantum jump spectrometer. Therewith, the frequency shift of the two spin states resulting from the magnetic coupling reaches for the first time an electronically detectable range.

•Jun 29, 2009•0 citations

Quantum dynamics of a charged particle in a penning trap

T. Steimle, G. Alber, J S Briggs

Zeitschrift für Physik D Atoms Molecules and Clusters•Mar 1, 1994•1 citation

Single atomic particle at rest in free space : new value for electron radius

HANS G. DEHMELT

Zero-point confinement in a suitable trap is briefly discussed as a quantum-mechanical equivalent of the classical single particle at rest in free space. So far, such confinement has been realized only for the 150 GHz cyclotron motion in geonium, a single electron permanently confined in a Penning trap. The most important result of mono-ion spectroscopy is a new, 10 000 times smaller, radius for the electron. This result was obtained by analyzing our g-factor data, g/2 = 1.001 159 652 193 (4), on the basis of a near-Dirac particle model. RF spectroscopy in geonium relies on the Continuous Stem Gerlach Effect in which a spin flip is detected as a small change in the ~ 60 MHz axial oscillation frequency of the electron in the trap. The Kaufmann Effect or relativistic mass shift may become a superior alternative : operating a geonium apparatus as a frequency selective mini-synchro-cyclotron has produced an easily detectable shift in the axial frequency. Like in Habann's 1926 split-anode magnetron, energy is quickly transferred from the oscillating electron to a resonant circuit, but by us for the purpose of detection, damping and cooling of the oscillatory motion. Conversely, localizing the electron to ~ 60 μm in the node of a standing wave in the trap cavity, where this cavity looks like a short, when it is resonant with the cyclotron motion, has made it possible to decrease the natural line width ten-fold. By driving the axial frequency not on resonance but on a side band higher by the ~ 12 kHz magnetron frequency, it has been possible to force the magnetron motion to absorb the excess in the photon energy and thereby shrink the magnetron radius to ~ 15 μm. By an analogous laser spectroscopic procedure the oscillation amplitude of a Ba+ ion in a different trap has been reduced to ~ 120 nm or less. Like in Nuclear Magnetic Resonance, confinement is now much smaller than the wave length and no motional side bands appear in the optical spectrum. Such a mono-ion oscillator, but using Tl+ or a similar ion, may make an optical frequency standard with a 1 000-day reproducibility of 10 -18 possible and thereby allow one to watch the expansion of the universe from one's laboratory.

Annales de Physique•Jan 1, 1985•7 citations
In this thesis is presented the realisation of `The Geonium Chip', a novel planar Penning trap. The chip is designed with the goal of building a truly scalable planar Penning trap, while retaining the accuracy of 3D traps. Manufactured with conventional metalon- silicon microfabrication techniques, the chip takes the 5 electrodes of the compensated cylindrical trap and projects them onto a ground-plane surface, thus forming the basis for its layout by reducing the electrode shape to an array of at rectangular surfaces. In this thesis I describe the conception, design and construction of a full cryogenic set-up, including the magnetics, for trapping and observing a single electron in the Geonium Chip Penning trap. The cyclotron mode of the trapped electron lies in the microwave regime, and thus the Geonium Chip has the potential to become a powerful building block for quantum microwave circuits, with coherent coupling to the cyclotron degree of freedom. This will also allow non-destructive measurement and interaction with the spin state of the electron. The development of the experimental process is detailed from scratch including the design, fabrication, and testing of the Geonium Chip, as well as the design, fabrication and testing of the experimental apparatus. The original solutions and space saving designs developed as part of the construction process are detailed, such as the custom on-chip cryogenic vacuum chamber, planar magnetic field source, and the LED-based electron loading system. The vacuum chamber and control systems are also described, and the in-house manufacturing capabilities of the Geonium group are detailed at length, with an emphasis on rapid prototyping high-accuracy components suitable for experimental use. The apparatus built within this PhD is within a few weeks of performing the first loading of electrons into the chip trap.
This PhD thesis presents experiments performed on a single proton stored in a Penning trap. The eigenmotion of an isolated, free proton could be detected electronically via a coupling to a resonance circuit. This represents a non-destructive measurement, i. e. the particle is not lost during the measurement. The free cyclotron frequency emerging from the measured eigenfrequencies is one of the two frequencies required for the determination of the magnetic moment. This enables a direct determination of the g-factor contrary to already existing works. Design, developing, and commissioning of the experimental setup have been accomplished within the scope of this work leading to a measuring accuracy of 10−7. The technical challenges for the determination of the second frequency (the Larmor frequency) arising from the smallness of the magnetic moment were mastered. Since the spin state required for this measurement is an internal degree of freedom, it can only be accessed through a coupling of the magnetic moment to the eigenmotion. A novel, hybrid penning trap is presented in this work, which imprints the spin information onto the eigenmotion, thus, realizing a quantum jump spectrometer. Therewith, the frequency shift of the two spin states resulting from the magnetic coupling reaches for the first time an electronically detectable range.
Zero-point confinement in a suitable trap is briefly discussed as a quantum-mechanical equivalent of the classical single particle at rest in free space. So far, such confinement has been realized only for the 150 GHz cyclotron motion in geonium, a single electron permanently confined in a Penning trap. The most important result of mono-ion spectroscopy is a new, 10 000 times smaller, radius for the electron. This result was obtained by analyzing our g-factor data, g/2 = 1.001 159 652 193 (4), on the basis of a near-Dirac particle model. RF spectroscopy in geonium relies on the Continuous Stem Gerlach Effect in which a spin flip is detected as a small change in the ~ 60 MHz axial oscillation frequency of the electron in the trap. The Kaufmann Effect or relativistic mass shift may become a superior alternative : operating a geonium apparatus as a frequency selective mini-synchro-cyclotron has produced an easily detectable shift in the axial frequency. Like in Habann's 1926 split-anode magnetron, energy is quickly transferred from the oscillating electron to a resonant circuit, but by us for the purpose of detection, damping and cooling of the oscillatory motion. Conversely, localizing the electron to ~ 60 μm in the node of a standing wave in the trap cavity, where this cavity looks like a short, when it is resonant with the cyclotron motion, has made it possible to decrease the natural line width ten-fold. By driving the axial frequency not on resonance but on a side band higher by the ~ 12 kHz magnetron frequency, it has been possible to force the magnetron motion to absorb the excess in the photon energy and thereby shrink the magnetron radius to ~ 15 μm. By an analogous laser spectroscopic procedure the oscillation amplitude of a Ba+ ion in a different trap has been reduced to ~ 120 nm or less. Like in Nuclear Magnetic Resonance, confinement is now much smaller than the wave length and no motional side bands appear in the optical spectrum. Such a mono-ion oscillator, but using Tl+ or a similar ion, may make an optical frequency standard with a 1 000-day reproducibility of 10 -18 possible and thereby allow one to watch the expansion of the universe from one's laboratory.