We consider the inverse scattering problem that arises in two-photon quantum imaging with interferometric measurements. We show that the two-point correlation function of the field contains information about the scattering medium at a spatial frequency of twice the Rayleigh bandwidth. The linearized inverse problem, however, yields reconstructions with a resolution of λ/2, where λ is the wavelength of light.
We consider the inverse scattering problem that arises in two-photon quantum imaging with interferometric measurements. We show that the two-point correlation function of the field contains information about the scattering medium at a spatial frequency of twice the Rayleigh bandwidth. The linearized inverse problem, however, yields reconstructions with a resolution of λ/2, where λ is the wavelength of light.
We study an inverse scattering problem in which the far-field spectral cross correlation functions of scattered fields are used to determine the unknown dielectric susceptibility of the scattering object. One-photon states for the incident field can resolve (at 100% visibility) twice as many Fourier components of the susceptibility compared with the (naïve) Rayleigh estimate, provided that the measurement is performed in the back-scattering regime. Coherent states are not capable of reaching this optimal resolution (or do so with negligible visibility). Using two-photon states improves upon the one-photon resolution, but the improvement (at 100% visibility) is smaller than twice, and it demands prior information on the object. This improvement can also be realized via two independent laser fields. The dependence on the prior information can be decreased (but not eliminated completely) upon using entangled states of two photons.
We consider the quantum field theory for a scalar model of the electromagnetic field interacting with a system of two-level atoms. In this setting, we show that it is possible to uniquely determine the density of atoms from measurements of the source to solution map for a system of nonlocal partial differential equations, which describe the scattering of a two-photon state from the atoms. The required measurements involve correlating the outputs of a point detector with an integrating detector, thereby exploiting information about the entanglement of the photons.
Microscopy, wavefront correction, image processing, optical data storage, and optical measurements in general constitute a very important domain of our present-day technologies. Optical technologies can directly benefit from the improvements brought by quantum effects and demonstrated by laboratory experiments, but their present complexity is an obstacle to such applications. A promising direction of research is certainly the use of orbital angular momentum of light to convey and process quantum information. Optical amplification is one of the key techniques in the handling of optical information. Two-photon imaging, sometimes labeled as “ghost imaging", is a striking effect based on the spatial correlations of light. Among the numerous problems that are currently studied under the general name of quantum imaging, the investigations concerning the quantum limits on optical resolution have a special importance. “Super-resolution techniques” have been studied for a long time at the classical level in the perspective of beating the Rayleigh limit of resolution.
Quantum imaging emerged quite recently as a breakthrough technology of overcoming the diffraction limit in microscopy and enhancement of optical resolution without the necessity to use hard radiation or perform scanning in the near field [1] , [2] . Both, the quantum imaging itself and the more “classical” techniques inspired by it (for example, super-resolution optical fluctuations imaging – SOFI [3] ), rely on detection and analysis of photon (intensity) correlations. Typically, it is believed that the more correlated illuminating light is used and the higher order of the correlations is measured, the larger super-resolution can be achieved. That conclusion is based on efficient narrowing of the point-spread function, which, however, does not necessarily imply better resolution as the ability to reconstruct smaller features of the investigated object successfully.
Imaging is the estimation of the spatial distribution of a physical object by measuring the optical radiation it emits, or by making use of an optical wave that interacts with the object, via reflection or transmission, for example, before being measured by a detector. The resolution of an imaging system is limited by the inability to localize the optical field at points of the object. Under otherwise ideal conditions, resolution is limited by diffraction. The sensitivity of an imaging system is limited by the uncertainty in the measurement. Under ideal conditions, this is determined by photon noise, which depends on the statistical fluctuations of the light. In conventional imaging systems, an extended detector, such as a CCD camera or an array detector, measures the spatial distribution of the optical intensity, which is proportional to the photon flux density. In interferometric systems, the spatial distribution of the optical field is inferred from measurements of the optical intensity. With the emergence of coherence theory, imaging systems based on measurements of the second-order coherence function at pairs of points in the detection plane were developed. An example is the imaging of an incoherent object based on the van Cittert-Zernike theorem. Imaging systems based on measurement of intensity correlation, or the photon coincidence rate, at pairs of points, were developed in the 1960s. A classic example of the photon-correlation imaging of an object emitting thermal light is stellar imaging using a Hanbury-Brown-Twiss intensity-correlation interferometer. More recently, two-photon light, which may be generated via spontaneous parametric downconversion in a second-order nonlinear optical crystal, has been used for imaging. This type of two-photon (or biphoton) imaging, which has come to be called quantum imaging, is also based on the measurement of photon coincidence by the use of photon-counting array detectors or by scanning two photon-counting detectors at pairs of points. To compare the resolution and sensitivity of imaging systems based on the aforementioned types of measurements, it is necessary to derive expressions for the measured quantities in terms of the object distribution. The point-spread functions based on such expressions can be used to assess the resolution. One measure of the sensitivity of the imaging process is the signal-to-noise ratio (SNR) of the measured variables. The statistical nature of the light source must be known in order to determine the SNR. The purpose of this chapter is to compare the resolution and sensitivity of photon-correlation imaging systems that make use of thermal light and two-photon light. We will henceforth refer to these two imaging modalities as classical and quantum photon-correlation imaging, or simply classical and quantum imaging, respectively. Clearly, light in other quantum states can also be used for imaging.
The resolution limit of standard imaging techniques is expressed by the Rayleigh criterion, which states that two point-like sources are difficult to resolve if their transverse separation is smaller that the Rayleigh length. While the criterion is useful in the case of direct detection imaging, other measurement techniques may not be subject to this limitation. Here we consider the use of imaging to estimate the distance between two incoherent point sources. In this framework, the Rayleigh criterion manifests itself through the so-called Rayleigh curse. The latter expresses the fact that the statistical error in the estimation increases for sub-wavelength separation. Here we show that, in the regime of weak signals, a structured measurement obtained by concatenating a linear interferometer with on-off photo-detection is immune to the Rayleigh curse. In this way we clarify the relation between imaging and interferometry, and establish the optimality of linear interferometry for an arbitrary number of incoherent sources.