Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)

Information Analysis for Quantum Imaging Optimization

Alexander B. Mikhalychev, Ilya Karuseichyk, Svetlana V. Vlasenko, Bänz Bessire, Dmitry A. Lyakhov, Dominik Ludewig Michels, André Stefanov, Dmitri S. Mogilevtsev

Published Jun 21, 2021• 0 citations
Publisher

Abstract

Quantum imaging emerged quite recently as a breakthrough technology of overcoming the diffraction limit in microscopy and enhancement of optical resolution without the necessity to use hard radiation or perform scanning in the near field [1] , [2] . Both, the quantum imaging itself and the more “classical” techniques inspired by it (for example, super-resolution optical fluctuations imaging – SOFI [3] ), rely on detection and analysis of photon (intensity) correlations. Typically, it is believed that the more correlated illuminating light is used and the higher order of the correlations is measured, the larger super-resolution can be achieved. That conclusion is based on efficient narrowing of the point-spread function, which, however, does not necessarily imply better resolution as the ability to reconstruct smaller features of the investigated object successfully.

DOI
10.1109/cleo/europe-eqec52157.2021.9541952

Related papers

Quantum super‐resolution imaging: a review and perspective

X. Yue, Hui Zhen Wu, Jizhou Wang +1 more

Quantum super-resolution imaging provides a nonlabeling method to surpass the diffraction limit of imaging systems. This technique relies on measurement of the second-order correlation function and usually employs spatially entangled photon sources. We introduce recent methods that achieve spatial resolution enhancement through quantum approaches, particularly the imaging techniques utilizing biphoton states. The fundamental mechanisms are discussed in detail to explain why biphoton states enable super-resolution. Additionally, we introduce multiple algorithms that extract the correlation function from the readings of two-dimensional detectors. Several cases are reviewed to evaluate the advantages and prospects of quantum imaging, along with a discussion of practical developments and potential applications.

Nanophotonics•Jan 15, 2025•16 citations

Quantum Imaging

Claude Fabre, Nicolas Treps

Microscopy, wavefront correction, image processing, optical data storage, and optical measurements in general constitute a very important domain of our present-day technologies. Optical technologies can directly benefit from the improvements brought by quantum effects and demonstrated by laboratory experiments, but their present complexity is an obstacle to such applications. A promising direction of research is certainly the use of orbital angular momentum of light to convey and process quantum information. Optical amplification is one of the key techniques in the handling of optical information. Two-photon imaging, sometimes labeled as “ghost imaging", is a striking effect based on the spatial correlations of light. Among the numerous problems that are currently studied under the general name of quantum imaging, the investigations concerning the quantum limits on optical resolution have a special importance. “Super-resolution techniques” have been studied for a long time at the classical level in the perspective of beating the Rayleigh limit of resolution.

Wiley eBooks•Apr 18, 2016•2 citations

Noise in Classical and Quantum Photon-Correlation Imaging

Bahaa E. A. Saleh, Malvin Carl Teich

Imaging is the estimation of the spatial distribution of a physical object by measuring the optical radiation it emits, or by making use of an optical wave that interacts with the object, via reflection or transmission, for example, before being measured by a detector. The resolution of an imaging system is limited by the inability to localize the optical field at points of the object. Under otherwise ideal conditions, resolution is limited by diffraction. The sensitivity of an imaging system is limited by the uncertainty in the measurement. Under ideal conditions, this is determined by photon noise, which depends on the statistical fluctuations of the light. In conventional imaging systems, an extended detector, such as a CCD camera or an array detector, measures the spatial distribution of the optical intensity, which is proportional to the photon flux density. In interferometric systems, the spatial distribution of the optical field is inferred from measurements of the optical intensity. With the emergence of coherence theory, imaging systems based on measurements of the second-order coherence function at pairs of points in the detection plane were developed. An example is the imaging of an incoherent object based on the van Cittert-Zernike theorem. Imaging systems based on measurement of intensity correlation, or the photon coincidence rate, at pairs of points, were developed in the 1960s. A classic example of the photon-correlation imaging of an object emitting thermal light is stellar imaging using a Hanbury-Brown-Twiss intensity-correlation interferometer. More recently, two-photon light, which may be generated via spontaneous parametric downconversion in a second-order nonlinear optical crystal, has been used for imaging. This type of two-photon (or biphoton) imaging, which has come to be called quantum imaging, is also based on the measurement of photon coincidence by the use of photon-counting array detectors or by scanning two photon-counting detectors at pairs of points. To compare the resolution and sensitivity of imaging systems based on the aforementioned types of measurements, it is necessary to derive expressions for the measured quantities in terms of the object distribution. The point-spread functions based on such expressions can be used to assess the resolution. One measure of the sensitivity of the imaging process is the signal-to-noise ratio (SNR) of the measured variables. The statistical nature of the light source must be known in order to determine the SNR. The purpose of this chapter is to compare the resolution and sensitivity of photon-correlation imaging systems that make use of thermal light and two-photon light. We will henceforth refer to these two imaging modalities as classical and quantum photon-correlation imaging, or simply classical and quantum imaging, respectively. Clearly, light in other quantum states can also be used for imaging.

SPIE eBooks•Mar 16, 2010•4 citations

Quantum image scanning microscopy: concept and considerations towards applicability

Ron Tenne, Yonatan Israel, Alexander Krupiński‐Ptaszek +5 more

Technological advancements in the creation, manipulation and detection of quantum states of light have motivated the application of such states to overcome classical limits in sensing and imaging. In particular, there has been a surge of recent interest in super-resolution imaging based on principles of quantum optics. However, the application of such schemes for practical imaging of biological samples is demanding in terms of signal-to-noise ratio, speed of acquisition and robustness with respect to sample labeling. Here, we re-introduce the concept of quantum image scanning microscopy (Q-ISM), a super-resolution method that enhances the classical image scanning microscopy (ISM) method by measuring photon correlations. Q-ISM was already utilized to achieve super-resolved images of a biological sample labeled with fluorescent nanoscrystals whose contrast is based entirely on a quantum optical phenomenon, photon antibunching. We present here an experimental demonstration of the method and discuss with further details its prospects for application in life science microscopy.

Optical and Quantum Sensing and Precision Metrology II•Mar 1, 2019•0 citations

Iterative Approach to Quantum Imaging Using Higher-Order Correlation Functions

Vadim Reut, Alexander B. Mikhalychev, Ilya L. Karuseychik +5 more

We demonstrate and discuss the quantum imaging technique based on the second and higher-order correlation functions, which enables correct reconstruction of objects with the pixel size much smaller than the classical resolution of the used optical system.

Quantum Information and Measurement (QIM)•Jan 1, 2017•0 citations

Photon Statistics Techniques for Super-Resolution Microscopy

I. P. Degiovanni, F. Picariello, Elena Losero +4 more

In this paper we summarise the advanced quantum super-resolution imaging technique based on photon statistics we theoretically developed and experimentally implemented. The super-resolution imaging technique adapts to any kind of non-Poissonian emitters, outperforming the corresponding classical SOFI method, in particular in low-light conditions. It provides a super-resolution improvement that scales with the square root of the highest-order central moments of the photon statistics. Furthermore, we will also show that our technique in combination with structured illumination will scale better than the highest-order central moments of the photon statistics, providing a promising avenue for non-invasive super-resolution microscopy.

Conference on Precision Electromagnetic Measurements•Sep 1, 2026•0 citations
Quantum imaging emerged quite recently as a breakthrough technology of overcoming the diffraction limit in microscopy and enhancement of optical resolution without the necessity to use hard radiation or perform scanning in the near field [1] , [2] . Both, the quantum imaging itself and the more “classical” techniques inspired by it (for example, super-resolution optical fluctuations imaging – SOFI [3] ), rely on detection and analysis of photon (intensity) correlations. Typically, it is believed that the more correlated illuminating light is used and the higher order of the correlations is measured, the larger super-resolution can be achieved. That conclusion is based on efficient narrowing of the point-spread function, which, however, does not necessarily imply better resolution as the ability to reconstruct smaller features of the investigated object successfully.
Quantum super-resolution imaging provides a nonlabeling method to surpass the diffraction limit of imaging systems. This technique relies on measurement of the second-order correlation function and usually employs spatially entangled photon sources. We introduce recent methods that achieve spatial resolution enhancement through quantum approaches, particularly the imaging techniques utilizing biphoton states. The fundamental mechanisms are discussed in detail to explain why biphoton states enable super-resolution. Additionally, we introduce multiple algorithms that extract the correlation function from the readings of two-dimensional detectors. Several cases are reviewed to evaluate the advantages and prospects of quantum imaging, along with a discussion of practical developments and potential applications.
Microscopy, wavefront correction, image processing, optical data storage, and optical measurements in general constitute a very important domain of our present-day technologies. Optical technologies can directly benefit from the improvements brought by quantum effects and demonstrated by laboratory experiments, but their present complexity is an obstacle to such applications. A promising direction of research is certainly the use of orbital angular momentum of light to convey and process quantum information. Optical amplification is one of the key techniques in the handling of optical information. Two-photon imaging, sometimes labeled as “ghost imaging", is a striking effect based on the spatial correlations of light. Among the numerous problems that are currently studied under the general name of quantum imaging, the investigations concerning the quantum limits on optical resolution have a special importance. “Super-resolution techniques” have been studied for a long time at the classical level in the perspective of beating the Rayleigh limit of resolution.
Imaging is the estimation of the spatial distribution of a physical object by measuring the optical radiation it emits, or by making use of an optical wave that interacts with the object, via reflection or transmission, for example, before being measured by a detector. The resolution of an imaging system is limited by the inability to localize the optical field at points of the object. Under otherwise ideal conditions, resolution is limited by diffraction. The sensitivity of an imaging system is limited by the uncertainty in the measurement. Under ideal conditions, this is determined by photon noise, which depends on the statistical fluctuations of the light. In conventional imaging systems, an extended detector, such as a CCD camera or an array detector, measures the spatial distribution of the optical intensity, which is proportional to the photon flux density. In interferometric systems, the spatial distribution of the optical field is inferred from measurements of the optical intensity. With the emergence of coherence theory, imaging systems based on measurements of the second-order coherence function at pairs of points in the detection plane were developed. An example is the imaging of an incoherent object based on the van Cittert-Zernike theorem. Imaging systems based on measurement of intensity correlation, or the photon coincidence rate, at pairs of points, were developed in the 1960s. A classic example of the photon-correlation imaging of an object emitting thermal light is stellar imaging using a Hanbury-Brown-Twiss intensity-correlation interferometer. More recently, two-photon light, which may be generated via spontaneous parametric downconversion in a second-order nonlinear optical crystal, has been used for imaging. This type of two-photon (or biphoton) imaging, which has come to be called quantum imaging, is also based on the measurement of photon coincidence by the use of photon-counting array detectors or by scanning two photon-counting detectors at pairs of points. To compare the resolution and sensitivity of imaging systems based on the aforementioned types of measurements, it is necessary to derive expressions for the measured quantities in terms of the object distribution. The point-spread functions based on such expressions can be used to assess the resolution. One measure of the sensitivity of the imaging process is the signal-to-noise ratio (SNR) of the measured variables. The statistical nature of the light source must be known in order to determine the SNR. The purpose of this chapter is to compare the resolution and sensitivity of photon-correlation imaging systems that make use of thermal light and two-photon light. We will henceforth refer to these two imaging modalities as classical and quantum photon-correlation imaging, or simply classical and quantum imaging, respectively. Clearly, light in other quantum states can also be used for imaging.
Technological advancements in the creation, manipulation and detection of quantum states of light have motivated the application of such states to overcome classical limits in sensing and imaging. In particular, there has been a surge of recent interest in super-resolution imaging based on principles of quantum optics. However, the application of such schemes for practical imaging of biological samples is demanding in terms of signal-to-noise ratio, speed of acquisition and robustness with respect to sample labeling. Here, we re-introduce the concept of quantum image scanning microscopy (Q-ISM), a super-resolution method that enhances the classical image scanning microscopy (ISM) method by measuring photon correlations. Q-ISM was already utilized to achieve super-resolved images of a biological sample labeled with fluorescent nanoscrystals whose contrast is based entirely on a quantum optical phenomenon, photon antibunching. We present here an experimental demonstration of the method and discuss with further details its prospects for application in life science microscopy.
In this paper we summarise the advanced quantum super-resolution imaging technique based on photon statistics we theoretically developed and experimentally implemented. The super-resolution imaging technique adapts to any kind of non-Poissonian emitters, outperforming the corresponding classical SOFI method, in particular in low-light conditions. It provides a super-resolution improvement that scales with the square root of the highest-order central moments of the photon statistics. Furthermore, we will also show that our technique in combination with structured illumination will scale better than the highest-order central moments of the photon statistics, providing a promising avenue for non-invasive super-resolution microscopy.