Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE Transactions on Applied Superconductivity

Working Point Adjustable DC-SQUID for the Readout of Gap Tunable Flux Qubit

Hui Deng, Yulin Wu, Yarui Zheng, Naheed Akhtar, Jie Fan, Xiaobo Zhu, Jie Li, Yirong Jin, Dongning Zheng

Published Feb 3, 2015• 8 citations
Publisher

Abstract

In flux qubits, qubit states are commonly read out by a dc superconducting quantum interference device (SQUID), which is inductively coupled to the qubit and works as a persistent current detector. However, neither the bottom nor the top regions of the critical current modulation curve of the SQUID can be used for the readout. In this paper, we show that a flux-trap loop inserted to the readout SQUID provides the ability to adjust the working point, which helps to avoid this constraint. This improvement is useful for some complicated flux qubit experiments.

DOI
10.1109/tasc.2015.2399272

Related papers

Gradiometric flux qubits with a tunable gap

M J Schwarz, J Goetz, Z Jiang +4 more

For gradiometric three-Josephson-junction flux qubits, we perform a systematic study on the tuning of the minimal transition frequency, the so-called qubit gap. By replacing one of the qubit's Josephson junctions by a dc superconducting quantum interference device (SQUID), the critical current of this SQUID and, in turn, the qubit gap can be tuned in situ by a control flux threading the SQUID loop. We present spectroscopic measurements demonstrating a well-defined controllability of the qubit gap between zero and more than 10 GHz. This is important for tuning the qubit into and out of resonance with other superconducting quantum circuits in scalable architectures, while still operating it at its symmetry point with optimal dephasing properties. The experimental data agree very well with model calculations based on the full qubit Hamiltonian. From a numerical fit, we determine the Josephson coupling and the charging energies of the qubit junctions. The derived values agree well with those measured for other junctions fabricated on the same chip. We also demonstrate the biasing of gradiometric flux qubits near the symmetry point by trapping an odd number of flux quanta in the gradiometer loop. In this way, we study the effect of the significant kinetic inductance, thereby obtaining valuable information for the qubit design.

arXiv:1210.3982•New Journal of Physics•Apr 4, 2013•39 citations

Quantum state detection of a superconducting flux qubit using a dc-SQUID in the inductive mode

Adrian Lupaşcu, C. J. P. M. Harmans, Johan E. Mooij

We present a readout method for superconducting flux qubits. The qubit quantum flux state can be measured by determining the Josephson inductance of an inductively coupled dc superconducting quantum interference device (dc-SQUID). We determine the response function of the dc-SQUID and its back-action on the qubit during measurement. Due to driving, the qubit energy relaxation rate depends on the spectral density of the measurement circuit noise at sum and difference frequencies of the qubit Larmor frequency and SQUID driving frequency. The qubit dephasing rate is proportional to the spectral density of circuit noise at the SQUID driving frequency. These features of the back-action are qualitatively different from the case when the SQUID is used in the usual switching mode. For a particular type of readout circuit with feasible parameters we find that single shot readout of a superconducting flux qubit is possible.

arXiv:cond-mat/0410730•Physical Review B•May 13, 2005•27 citations

Adjusting the dc-SQUID working point by a flux trapping loop for readout of gap-tunable flux qubit

Xiaobo Zhu, Yulin Wu, Hui Deng +5 more

Bulletin of the American Physical Society•Mar 5, 2015•0 citations

Tuning an rf-SQUID flux qubit system's potential with magnetic flux bias

Tao Hua, Weiwei Xu, Jianxin Shi +4 more

At an extremely low temperature of 20 mK, we measured the loop current in a tunable rf superconducting quantum interference device (SQUID) with a dc-SQUID. By adjusting the magnetic flux applied to the rf-SQUID loop ( Φ f ) and the small dc-SQUID ( Φ f cjj ), respectively, the potential shape of the system can be fully controlled in situ . Variation in the transition step and overlap size in the switching current with a barrier flux bias are analyzed, from which we can obtain some relevant device parameters and build a model to explain the experimental phenomenon.

Chinese Physics B•Sep 1, 2012•4 citations

Dc SQUID sensitivity for readout of entangled state quantum bits

H Tanaka, Y Sekine, S Saito +1 more

We propose a scheme for entangled state measurement at flux qubits (quantum bits) depending on the sensitivity measurement of a dc SQUID (superconducting quantum interference device). The dc SQUID is used as a flux qubit readout device. The switching current distribution of the dc SQUID is sufficiently narrow to distinguish between two ground states of three Josephson junction qubits with a large mutual inductance between a qubit and the dc SQUID. However, discrimination between two ground states becomes difficult with the smaller mutual inductance that is preferable for qubit coherence. We employed averaging to increase the effective sensitivity. However the averaging smears out the entanglement over two qubits. We found that a Bell-pair measurement can be performed with flux qubits to prove the existence of an entangled state over two qubits. The pre-ensembled measurement scheme, in which our flux qubit readouts work, is preferable to entangled state measurement.

arXiv:cond-mat/0108231•Superconductor Science and Technology•Nov 21, 2001•8 citations

Coherent operation of a gap-tunable flux qubit

Xiaobo Zhu, Alexander Kemp, Shiro Saito +1 more

We replace the Josephson junction defining a three-junction flux qubit’s properties with a tunable direct current superconducting quantum interference devices (dc-SQUIDs) in order to tune the qubit gap during the experiment. We observe different gaps as a function of the external magnetic pre-biasing field and the local magnetic field through the dc-SQUID controlled by high-bandwidth on chip control lines. The persistent current and gap behavior correspond to numerical simulation results. We set the sensitivity of the gap on the control lines during the sample design stage. With a tuning range of several gigahertz on a qubit dynamics timescale, we observe coherent system dynamics at the degeneracy point.

arXiv:1008.4016•Applied Physics Letters•Sep 6, 2010•69 citations
In flux qubits, qubit states are commonly read out by a dc superconducting quantum interference device (SQUID), which is inductively coupled to the qubit and works as a persistent current detector. However, neither the bottom nor the top regions of the critical current modulation curve of the SQUID can be used for the readout. In this paper, we show that a flux-trap loop inserted to the readout SQUID provides the ability to adjust the working point, which helps to avoid this constraint. This improvement is useful for some complicated flux qubit experiments.
For gradiometric three-Josephson-junction flux qubits, we perform a systematic study on the tuning of the minimal transition frequency, the so-called qubit gap. By replacing one of the qubit's Josephson junctions by a dc superconducting quantum interference device (SQUID), the critical current of this SQUID and, in turn, the qubit gap can be tuned in situ by a control flux threading the SQUID loop. We present spectroscopic measurements demonstrating a well-defined controllability of the qubit gap between zero and more than 10 GHz. This is important for tuning the qubit into and out of resonance with other superconducting quantum circuits in scalable architectures, while still operating it at its symmetry point with optimal dephasing properties. The experimental data agree very well with model calculations based on the full qubit Hamiltonian. From a numerical fit, we determine the Josephson coupling and the charging energies of the qubit junctions. The derived values agree well with those measured for other junctions fabricated on the same chip. We also demonstrate the biasing of gradiometric flux qubits near the symmetry point by trapping an odd number of flux quanta in the gradiometer loop. In this way, we study the effect of the significant kinetic inductance, thereby obtaining valuable information for the qubit design.
We present a readout method for superconducting flux qubits. The qubit quantum flux state can be measured by determining the Josephson inductance of an inductively coupled dc superconducting quantum interference device (dc-SQUID). We determine the response function of the dc-SQUID and its back-action on the qubit during measurement. Due to driving, the qubit energy relaxation rate depends on the spectral density of the measurement circuit noise at sum and difference frequencies of the qubit Larmor frequency and SQUID driving frequency. The qubit dephasing rate is proportional to the spectral density of circuit noise at the SQUID driving frequency. These features of the back-action are qualitatively different from the case when the SQUID is used in the usual switching mode. For a particular type of readout circuit with feasible parameters we find that single shot readout of a superconducting flux qubit is possible.
At an extremely low temperature of 20 mK, we measured the loop current in a tunable rf superconducting quantum interference device (SQUID) with a dc-SQUID. By adjusting the magnetic flux applied to the rf-SQUID loop ( Φ f ) and the small dc-SQUID ( Φ f cjj ), respectively, the potential shape of the system can be fully controlled in situ . Variation in the transition step and overlap size in the switching current with a barrier flux bias are analyzed, from which we can obtain some relevant device parameters and build a model to explain the experimental phenomenon.
We propose a scheme for entangled state measurement at flux qubits (quantum bits) depending on the sensitivity measurement of a dc SQUID (superconducting quantum interference device). The dc SQUID is used as a flux qubit readout device. The switching current distribution of the dc SQUID is sufficiently narrow to distinguish between two ground states of three Josephson junction qubits with a large mutual inductance between a qubit and the dc SQUID. However, discrimination between two ground states becomes difficult with the smaller mutual inductance that is preferable for qubit coherence. We employed averaging to increase the effective sensitivity. However the averaging smears out the entanglement over two qubits. We found that a Bell-pair measurement can be performed with flux qubits to prove the existence of an entangled state over two qubits. The pre-ensembled measurement scheme, in which our flux qubit readouts work, is preferable to entangled state measurement.
We replace the Josephson junction defining a three-junction flux qubit’s properties with a tunable direct current superconducting quantum interference devices (dc-SQUIDs) in order to tune the qubit gap during the experiment. We observe different gaps as a function of the external magnetic pre-biasing field and the local magnetic field through the dc-SQUID controlled by high-bandwidth on chip control lines. The persistent current and gap behavior correspond to numerical simulation results. We set the sensitivity of the gap on the control lines during the sample design stage. With a tuning range of several gigahertz on a qubit dynamics timescale, we observe coherent system dynamics at the degeneracy point.