Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Nature Communications

High-resolution vector microwave magnetometry based on solid-state spins in diamond

Pengfei Wang, Zhenheng Yuan, Pu Huang, Xing Rong, Mengqi Wang, Xiangkun Xu, Chang‐Kui Duan, Chenyong Ju, Fazhan Shi, Jiangfeng Du

Published Mar 23, 2015• 146 citations
Publisher

Abstract

The measurement of the microwave field is crucial for many developments in microwave technology and related applications. However, measuring microwave fields with high sensitivity and spatial resolution under ambient conditions remains elusive. In this work, we propose and experimentally demonstrate a scheme to measure both the strength and orientation of the microwave magnetic field by utilizing the quantum coherent dynamics of nitrogen vacancy centres in diamond. An angular resolution of 5.7 mrad and a sensitivity of 1.0 μT Hz(-1/2) are achieved at a microwave frequency of 2.6000 GHz, and the microwave magnetic field vectors generated by a copper wire are precisely reconstructed. The solid-state microwave magnetometry with high resolution and wide frequency range that can work under ambient conditions proposed here enables unique potential applications over other state-of-art microwave magnetometry.

DOI
10.1038/ncomms7631

Related papers

Using a single nitrogen-vacancy center in diamond to detect microwave magnetic field vectors at resonant frequency

Mengyuan Cai, Changfeng Weng, Yuqing Zhu +3 more

This study introduces a method for reconstructing vector microwave magnetic fields using a single nitrogen-vacancy (NV) center in locally strong effective fields with two different orientations in diamond, without the previously required external magnetic field. Due to the varying orientations of the effective fields, NV centers exhibit two distinct sets of switchable ground states. The resonant Rabi oscillations of an NV center in these two distinct states were utilized to reconstruct vector microwave magnetic fields. Remarkably, this technique achieves an angular resolution of 0.02 mrad/Hz. Overcoming the limitations inherent in previous practices of using NV ensembles, this breakthrough has the potential to substantially enhance both the spatial resolution and the sensitivity of microwave magnetic field imaging, a meaningful development for various scientific and technological applications.

Applied Physics Letters•Apr 8, 2024•4 citations

Wideband microwave resonator for NV center vector magnetometry

S. V. Bolshedvorskii, E. A. Koreshin, V. V. Soshenko +10 more

The nitrogen-vacancy (NV) color center in diamond has found applications in magnetometry across various geometrical scales. In particular, vector magnetometry using hand-held devices with low power consumption is of interest for mobile and geological applications. However, such a device requires efficient driving of the four different orientations of the NV center, thus placing demands on a broadband microwave resonator that provides a uniform and highly insensitive microwave magnetic field at the resonance frequencies of the NV centers. Here, we propose a unique planar resonator design that enables efficient driving of all four orientations of NV color centers over a 100 MHz range with only 0.5 W of microwave input power and 250 mW of laser power, allowing vector magnetic field measurements. Using the planar resonator to drive NV centers in diamond, a compact vector magnetometer was fabricated and experimentally studied. The sensitivity of the device is about \[{1.2\text{ nT}}/{\sqrt{\text{Hz}}}\;\]. While this is not a record sensitivity for diamond-based magnetometers, this device occupies its own niche as a compact hand-held magnetometer.

quant-pharXiv:2610.13379•Oct 12, 2026

Microwave-Free Vector Magnetometry with Nitrogen-Vacancy Centers along a Single Axis in Diamond

Huijie Zheng, Zhiyin Sun, Georgios Chatzidrosos +8 more

Sensing vector magnetic fields is important to many applications in fundamental physics, bioimaging, and materials science. Sensors exploiting nitrogen-vacancy (N-$V$) centers typically interrogate N-$V$ ensembles oriented in all directions, thwarting nanoscale spatial resolution. Utilizing the level anticrossing in the triplet ground state, the authors demonstrate a $m\phantom{\rule{0}{0ex}}i\phantom{\rule{0}{0ex}}c\phantom{\rule{0}{0ex}}r\phantom{\rule{0}{0ex}}o\phantom{\rule{0}{0ex}}w\phantom{\rule{0}{0ex}}a\phantom{\rule{0}{0ex}}v\phantom{\rule{0}{0ex}}e\ensuremath{-}f\phantom{\rule{0}{0ex}}r\phantom{\rule{0}{0ex}}e\phantom{\rule{0}{0ex}}e$ vector magnetometer that simultaneously measures all Cartesian components of the field, offering wide-band operation and high, equal sensitivity in all directions. This technique may work for single N-$V$ centers as well as ensembles, extending vector measurements to the nanoscale, at ambient temperatures.

arXiv:1904.04361•Physical Review Applied•Apr 9, 2020•80 citations

Detuning-insensitive wide-field imaging of vector microwave fields with diamond sensors

Xiu-Qi Chen, Rui-Zhi Zhang, Gang-Qin Liu +1 more

Nitrogen vacancy (NV) centers in diamond have precipitated profound advances in microwave detection, manifesting themselves both in spatial resolution and sensitivity. However, typical methods based on Rabi oscillations are subject to detunings due to thermal and magnetic fluctuations and/or gradients, which introduce systematic errors and render the measurements susceptible to environmental perturbations. Here, we propose and demonstrate a novel approach for determining both the magnitude and direction of microwaves, by exploiting the spectral line broadening effect in the optically detected magnetic resonance of NV centers. This method eliminates the requirement of aligning the MW frequency to the spin transitions and is therefore immune to variations and inhomogeneities of the magnetic field and temperature, providing an optimal tool for fast imaging applications. With this method, we achieved wide-field imaging of near field microwaves generated with a microscale $\rmΩ$-pattern antenna with a resolution of 800\,nm. Combining with the vector detection using multi-axis NVs, a full reconstruction of the vector microwave fields is obtained. Besides, our scheme also exhibits excellent linearity over a broad range of MW amplitudes, and the scale is theoretically calculated to be more than four orders. Our results augment the applicability of diamond-based microwave devices in applications under complex scenarios, especially where large dynamic range, fast test speed, and high spatial resolution are demanded.

physics.ins-detCross-listedarXiv:2512.05986•Dec 1, 2025

High-resolution and wide-frequency-range magnetic spectroscopy with solid-state spin ensembles

Zechuan Yin, Justin J. Welter, Connor Hart +2 more

Quantum systems composed of solid-state electronic spins can be sensitive detectors of narrowband magnetic fields. A prominent example is the nitrogen-vacancy (NV) center in diamond, which has been employed for magnetic spectroscopy with high spatial and spectral resolution. However, NV-diamond spectroscopy protocols are typically based on dynamical decoupling sequences, which are limited to low-frequency signals ( ≲ 20 MHz) due to the technical requirements on microwave (MW) pulses used to manipulate NV electronic spins. In this work, we experimentally demonstrate a high-resolution magnetic spectroscopy protocol that integrates a quantum frequency mixing (QFM) effect in a dense NV ensemble with coherently averaged synchronized readout (CASR) to provide both a wide range of signal frequency detection and sub-Hz spectral resolution. We assess the sensitivity of this QFM-CASR protocol across a frequency range of 10 MHz to 4 GHz. By measuring the spectra of multi-frequency signals near 0.6, 2.4 and 4 GHz, we demonstrate sub-Hz spectral resolution with a nT-scale noise floor for the target signal, and precise phase measurement with error < 1 ∘ . Compared to state-of-the-art NV-diamond techniques for high-resolution magnetic spectroscopy, the QFM-CASR protocol extends the signal frequency range by more than an order of magnitude, enabling applications in radio frequency (RF) and MW signal microscopy and analysis, as well as tesla-scale nuclear magnetic resonance (NMR) spectroscopy of small samples.

npj Quantum Information•Dec 3, 2025•2 citations

High-resolution, Wide-frequency-range Magnetic Spectroscopy with Solid-state Spin Ensembles

Ronald Lee Walsworth, Zechuan Yin, Justin J. Welter +2 more

Abstract Quantum systems composed of solid-state electronic spins can be sensitive detectors of narrowband magnetic fields. A prominent example is the nitrogen-vacancy (NV) center in diamond, which has been employed for magnetic spectroscopy with high spatial and spectral resolution. However, NV-diamond spectroscopy protocols are typically based on dynamical decoupling sequences, which are limited to low-frequency signals (≲ 20 MHz) due to the technical requirements on microwave (MW) pulses used to manipulate NV electronic spins. In this work, we experimentally demonstrate a high-resolution magnetic spectroscopy protocol that integrates a quantum frequency mixing (QFM) effect in a dense NV ensemble with coherently averaged synchronized readout (CASR) to provide both a wide range of signal frequency detection and sub-Hz spectral resolution. We assess the sensitivity of this QFM-CASR protocol across a frequency range of 10 MHz to 4 GHz. By measuring the spectra of multi-frequency signals near 0.6, 2.4 and 4 GHz, we demonstrate sub-Hz spectral resolution with a nT-scale noise floor for the target signal, and precise phase measurement with error <1°. Compared to state-of-the-art NV-diamond techniques for narrowband magnetic spectroscopy, the QFM-CASR protocol greatly extends the detectable frequency range, enabling applications in high-frequency radio frequency (RF) and MW signal microscopy and analysis, as well as tesla-scale nuclear magnetic resonance (NMR) spectroscopy of small samples.

•Jan 24, 2025•0 citations
The measurement of the microwave field is crucial for many developments in microwave technology and related applications. However, measuring microwave fields with high sensitivity and spatial resolution under ambient conditions remains elusive. In this work, we propose and experimentally demonstrate a scheme to measure both the strength and orientation of the microwave magnetic field by utilizing the quantum coherent dynamics of nitrogen vacancy centres in diamond. An angular resolution of 5.7 mrad and a sensitivity of 1.0 μT Hz(-1/2) are achieved at a microwave frequency of 2.6000 GHz, and the microwave magnetic field vectors generated by a copper wire are precisely reconstructed. The solid-state microwave magnetometry with high resolution and wide frequency range that can work under ambient conditions proposed here enables unique potential applications over other state-of-art microwave magnetometry.
This study introduces a method for reconstructing vector microwave magnetic fields using a single nitrogen-vacancy (NV) center in locally strong effective fields with two different orientations in diamond, without the previously required external magnetic field. Due to the varying orientations of the effective fields, NV centers exhibit two distinct sets of switchable ground states. The resonant Rabi oscillations of an NV center in these two distinct states were utilized to reconstruct vector microwave magnetic fields. Remarkably, this technique achieves an angular resolution of 0.02 mrad/Hz. Overcoming the limitations inherent in previous practices of using NV ensembles, this breakthrough has the potential to substantially enhance both the spatial resolution and the sensitivity of microwave magnetic field imaging, a meaningful development for various scientific and technological applications.
The nitrogen-vacancy (NV) color center in diamond has found applications in magnetometry across various geometrical scales. In particular, vector magnetometry using hand-held devices with low power consumption is of interest for mobile and geological applications. However, such a device requires efficient driving of the four different orientations of the NV center, thus placing demands on a broadband microwave resonator that provides a uniform and highly insensitive microwave magnetic field at the resonance frequencies of the NV centers. Here, we propose a unique planar resonator design that enables efficient driving of all four orientations of NV color centers over a 100 MHz range with only 0.5 W of microwave input power and 250 mW of laser power, allowing vector magnetic field measurements. Using the planar resonator to drive NV centers in diamond, a compact vector magnetometer was fabricated and experimentally studied. The sensitivity of the device is about 1.2 nT/Hz  {1.2\text{ nT}}/{\sqrt{\text{Hz}}}\;1.2 nT/Hz​. While this is not a record sensitivity for diamond-based magnetometers, this device occupies its own niche as a compact hand-held magnetometer.
Sensing vector magnetic fields is important to many applications in fundamental physics, bioimaging, and materials science. Sensors exploiting nitrogen-vacancy (N-VVV) centers typically interrogate N-VVV ensembles oriented in all directions, thwarting nanoscale spatial resolution. Utilizing the level anticrossing in the triplet ground state, the authors demonstrate a $m\phantom{\rule{0}{0ex}}i\phantom{\rule{0}{0ex}}c\phantom{\rule{0}{0ex}}r\phantom{\rule{0}{0ex}}o\phantom{\rule{0}{0ex}}w\phantom{\rule{0}{0ex}}a\phantom{\rule{0}{0ex}}v\phantom{\rule{0}{0ex}}e\ensuremath{-}f\phantom{\rule{0}{0ex}}r\phantom{\rule{0}{0ex}}e\phantom{\rule{0}{0ex}}e$ vector magnetometer that simultaneously measures all Cartesian components of the field, offering wide-band operation and high, equal sensitivity in all directions. This technique may work for single N-VVV centers as well as ensembles, extending vector measurements to the nanoscale, at ambient temperatures.
Nitrogen vacancy (NV) centers in diamond have precipitated profound advances in microwave detection, manifesting themselves both in spatial resolution and sensitivity. However, typical methods based on Rabi oscillations are subject to detunings due to thermal and magnetic fluctuations and/or gradients, which introduce systematic errors and render the measurements susceptible to environmental perturbations. Here, we propose and demonstrate a novel approach for determining both the magnitude and direction of microwaves, by exploiting the spectral line broadening effect in the optically detected magnetic resonance of NV centers. This method eliminates the requirement of aligning the MW frequency to the spin transitions and is therefore immune to variations and inhomogeneities of the magnetic field and temperature, providing an optimal tool for fast imaging applications. With this method, we achieved wide-field imaging of near field microwaves generated with a microscale Ω\rmΩΩ-pattern antenna with a resolution of 800\,nm. Combining with the vector detection using multi-axis NVs, a full reconstruction of the vector microwave fields is obtained. Besides, our scheme also exhibits excellent linearity over a broad range of MW amplitudes, and the scale is theoretically calculated to be more than four orders. Our results augment the applicability of diamond-based microwave devices in applications under complex scenarios, especially where large dynamic range, fast test speed, and high spatial resolution are demanded.
Quantum systems composed of solid-state electronic spins can be sensitive detectors of narrowband magnetic fields. A prominent example is the nitrogen-vacancy (NV) center in diamond, which has been employed for magnetic spectroscopy with high spatial and spectral resolution. However, NV-diamond spectroscopy protocols are typically based on dynamical decoupling sequences, which are limited to low-frequency signals ( ≲ 20 MHz) due to the technical requirements on microwave (MW) pulses used to manipulate NV electronic spins. In this work, we experimentally demonstrate a high-resolution magnetic spectroscopy protocol that integrates a quantum frequency mixing (QFM) effect in a dense NV ensemble with coherently averaged synchronized readout (CASR) to provide both a wide range of signal frequency detection and sub-Hz spectral resolution. We assess the sensitivity of this QFM-CASR protocol across a frequency range of 10 MHz to 4 GHz. By measuring the spectra of multi-frequency signals near 0.6, 2.4 and 4 GHz, we demonstrate sub-Hz spectral resolution with a nT-scale noise floor for the target signal, and precise phase measurement with error < 1 ∘ . Compared to state-of-the-art NV-diamond techniques for high-resolution magnetic spectroscopy, the QFM-CASR protocol extends the signal frequency range by more than an order of magnitude, enabling applications in radio frequency (RF) and MW signal microscopy and analysis, as well as tesla-scale nuclear magnetic resonance (NMR) spectroscopy of small samples.
Abstract Quantum systems composed of solid-state electronic spins can be sensitive detectors of narrowband magnetic fields. A prominent example is the nitrogen-vacancy (NV) center in diamond, which has been employed for magnetic spectroscopy with high spatial and spectral resolution. However, NV-diamond spectroscopy protocols are typically based on dynamical decoupling sequences, which are limited to low-frequency signals (≲ 20 MHz) due to the technical requirements on microwave (MW) pulses used to manipulate NV electronic spins. In this work, we experimentally demonstrate a high-resolution magnetic spectroscopy protocol that integrates a quantum frequency mixing (QFM) effect in a dense NV ensemble with coherently averaged synchronized readout (CASR) to provide both a wide range of signal frequency detection and sub-Hz spectral resolution. We assess the sensitivity of this QFM-CASR protocol across a frequency range of 10 MHz to 4 GHz. By measuring the spectra of multi-frequency signals near 0.6, 2.4 and 4 GHz, we demonstrate sub-Hz spectral resolution with a nT-scale noise floor for the target signal, and precise phase measurement with error <1°. Compared to state-of-the-art NV-diamond techniques for narrowband magnetic spectroscopy, the QFM-CASR protocol greatly extends the detectable frequency range, enabling applications in high-frequency radio frequency (RF) and MW signal microscopy and analysis, as well as tesla-scale nuclear magnetic resonance (NMR) spectroscopy of small samples.