Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Applied Physics Letters

Subquantum limit Josephson magnetometry

Mark Jeffery

Published May 22, 1995• 4 citations
Publisher

Abstract

A reactive dc Josephson inductive kinetic amplifier (IKA) has been proposed to measure weak dc magnetic fields with high sensitivity. In this letter the quantum noise intrinsic to the IKA is analyzed and the device is shown to operate as a back-action evasion magnetic flux amplifier capable of subquantum limit detection of weak dc magnetic fields.

DOI
10.1063/1.113466

Related papers

Low noise Josephson dc parametric amplifier

Mark Jeffery, Eiichi Goto

We describe a new Josephson Inductive Kinetic Amplifier (IKA) designed to measure weak dc magnetic fields with low noise. The IKA operates by frequency shifting dc input to a high frequency range and then parametrically amplifying. The IKA does not require dc offset and by frequency shifting dc input 1/f noise may be reduced. We define the circuit Lagrangian and derive the system equations. An analytical expression for the IKA transfer function is derived and the frequency response, optimal parameters, and stability are all obtained from the analytic theory. We also calculate the temperature at which the internal Nyquist noise should equal the quantum sensitivity limit. Our analysis suggests that the IKA could be more sensitive than the conventional dc Superconducting Quantum Interference Device.

Journal of Applied Physics•Jun 1, 1994•4 citations

Even harmonic Josephson magnetometry

Q. Geng, Eiichi Goto

A novel Josephson junction magnetometry scheme is proposed in which magnetic flux is applied to Josephson junctions with a modulation flux +or-z( Phi /sub 0//2 pi ) cos omega t. Two Josephson junctions are used in a push-pull mode to perform amplification through two mechanisms: negative inductance amplification of DC (low frequency) components and parametric amplification of the second harmonic. The second harmonic component of the Josephson currents, which is directly proportional to the strength of the input flux, is then selected and amplified by a phase-sensitive detector. Computer simulations show that the device behaves very well as a magnetic flux sensor with a DC offset free feature. The device's parameters and noise problems are also discussed. A preliminary analysis indicates that it is likely to have a better sensitivity than superconducting quantum interference devices.>

IEEE Transactions on Applied Superconductivity•Mar 1, 1993•0 citations

Selective single- and double-mode quantum-limited amplifier

Abdul Mohamed, Elham Zohari, Jarryd J. Pla +2 more

A quantum-limited amplifier enables the amplification of weak signals while introducing minimal noise dictated by the principles of quantum mechanics. Such amplifiers serve a broad spectrum of applications in quantum computing, including fast and accurate readout of superconducting qubits and spins, as well as various uses in quantum sensing and metrology. Parametric amplification, primarily developed with use of Josephson junctions, has evolved into the leading technology for highly effective microwave measurements within quantum circuits. Despite their significant contributions, these amplifiers face fundamental limitations, such as their inability to handle high powers, their sensitivity to parasitic magnetic fields, and particularly their limitation to operate only at millikelvin temperatures. To tackle these challenges, here we experimentally develop a novel quantum-limited amplifier based on superconducting kinetic inductance and present an extensive theoretical model to describe this nonlinear coupled-mode system. Our device surpasses the conventional constraints associated with Josephson-junction amplifiers by operating at much higher temperatures up to 4.5 K. With two distinct spectral modes and tunability through bias current, this amplifier can operate selectively in both the single-mode-amplification regime and the double-mode-amplification regime near the quantum noise limit. Using a nonlinear thin film exhibiting kinetic inductance, our device attains gain exceeding 50 dB in a single-mode configuration and 32 dB in a double-mode configuration, while adding 0.82 input-referred noise quanta. Importantly, this amplifier eliminates the need for Josephson junctions, resulting in the capability to handle significantly higher powers than Josephson junction--based amplifiers. It also demonstrates resilience in the presence of magnetic fields, offers a straightforward design, and increases reliability. This positions the amplifier as a versatile solution for quantum applications and facilitates its integration into future superconducting quantum computers.

arXiv:2311.11496•Physical Review Applied•Jun 24, 2024•8 citations

Radio-Frequency Bloch-Transistor Electrometer

Alexander B Zorin

A quantum electrometer is proposed which is based on charge modulation of the Josephson supercurrent in the Bloch transistor inserted in a superconducting ring. As this ring is inductively coupled to a high- Q resonance tank circuit, the variations of the charge on the transistor island are converted into variations of amplitude and phase of oscillations in the tank. These variations are amplified and then detected. At sufficiently low temperature of the tank the device sensitivity is determined by the energy resolution of the amplifier, that can be reduced down to the standard quantum limit of 1 / 2Planck's over 2pi. A "back-action-evading" scheme of subquantum limit measurements is proposed.

arXiv:cond-mat/0012314•Physical Review Letters•Apr 9, 2001•35 citations

A Study of the Principles and Applications of Superconducting Quantum Sensors for Microwave and Magnetic Sensing

Ravindranadh Jammalamadugu

Superconducting quantum sensors use flux quantization, the Josephson effect and low-loss microwave circuits to measure magnetic flux, microwave signals and photon flux close to fundamental limits. In this review we follow the field from the Bardeen–Cooper–Schrieffer theory and the discovery of Josephson tunnelling to SQUID magnetometers, microwave kinetic inductance detectors and quantum-limited parametric amplifiers. We explain how dc and rf SQUIDs, superconducting resonators, and Josephson and kinetic-inductance amplifiers work, and we describe one measurement chain that covers them all, with separate excitation, response, amplification, control and readout paths and a fluxlocked-loop variant for SQUIDs. Flux and field noise, noise-equivalent power, added noise, bandwidth and dynamic range are defined and compared using numbers taken directly from the primary literature, together with the conditions under which they were measured. We then survey applications in biomagnetism, astronomical imaging, qubit readout and dark-matter searches, and close with the open problems of scalability, environmental noise and fair benchmarking.

Ci-STEM Journal of Digital Technologies and Expert Systems•Jan 1, 2026•0 citations

Magnetic Field-Resilient Quantum-Limited Parametric Amplifier

Mingrui Xu, Risheng Cheng, Yufeng Wu +2 more

Superconducting parametric amplifiers are crucial components in microwave quantum circuits for enabling quantum-limited signal readout.The best-performing such amplifiers are often based on Josephson junctions, which however are sensitive to magnetic fields.Therefore, they require magnetic shields and are not easily integratable with other quantum systems that operate within magnetic fields, such as spinensemble quantum memories.To tackle this challenge, we develop a kinetic inductance-based parametric amplifier featuring a NbN nanobridge instead of Josephson junctions, which provides the desired nonlinearity for a strong parametric gain up to 42 dB.The added noise of this nanobridge kinetic-inductance parametric amplifier (hereby referred to as NKPA) is calibrated and found to be 0.59 ± 0.03 quanta for phase-preserving amplification, approaching the quantum limit of 0.5 quanta.Most importantly, we show that such excellent noise performance is preserved in an in-plane magnetic field up to 427 mT, the maximum field available in our experiment.This magnetic-field-resilient parametric amplifier presents an opportunity towards addressing single electron-spin resonance and more efficient search for axions as well as Majorana fermions.

arXiv:2209.13652•PRX Quantum•Feb 28, 2023•50 citations
A reactive dc Josephson inductive kinetic amplifier (IKA) has been proposed to measure weak dc magnetic fields with high sensitivity. In this letter the quantum noise intrinsic to the IKA is analyzed and the device is shown to operate as a back-action evasion magnetic flux amplifier capable of subquantum limit detection of weak dc magnetic fields.
We describe a new Josephson Inductive Kinetic Amplifier (IKA) designed to measure weak dc magnetic fields with low noise. The IKA operates by frequency shifting dc input to a high frequency range and then parametrically amplifying. The IKA does not require dc offset and by frequency shifting dc input 1/f noise may be reduced. We define the circuit Lagrangian and derive the system equations. An analytical expression for the IKA transfer function is derived and the frequency response, optimal parameters, and stability are all obtained from the analytic theory. We also calculate the temperature at which the internal Nyquist noise should equal the quantum sensitivity limit. Our analysis suggests that the IKA could be more sensitive than the conventional dc Superconducting Quantum Interference Device.
A novel Josephson junction magnetometry scheme is proposed in which magnetic flux is applied to Josephson junctions with a modulation flux +or-z( Phi /sub 0//2 pi ) cos omega t. Two Josephson junctions are used in a push-pull mode to perform amplification through two mechanisms: negative inductance amplification of DC (low frequency) components and parametric amplification of the second harmonic. The second harmonic component of the Josephson currents, which is directly proportional to the strength of the input flux, is then selected and amplified by a phase-sensitive detector. Computer simulations show that the device behaves very well as a magnetic flux sensor with a DC offset free feature. The device's parameters and noise problems are also discussed. A preliminary analysis indicates that it is likely to have a better sensitivity than superconducting quantum interference devices.>
A quantum-limited amplifier enables the amplification of weak signals while introducing minimal noise dictated by the principles of quantum mechanics. Such amplifiers serve a broad spectrum of applications in quantum computing, including fast and accurate readout of superconducting qubits and spins, as well as various uses in quantum sensing and metrology. Parametric amplification, primarily developed with use of Josephson junctions, has evolved into the leading technology for highly effective microwave measurements within quantum circuits. Despite their significant contributions, these amplifiers face fundamental limitations, such as their inability to handle high powers, their sensitivity to parasitic magnetic fields, and particularly their limitation to operate only at millikelvin temperatures. To tackle these challenges, here we experimentally develop a novel quantum-limited amplifier based on superconducting kinetic inductance and present an extensive theoretical model to describe this nonlinear coupled-mode system. Our device surpasses the conventional constraints associated with Josephson-junction amplifiers by operating at much higher temperatures up to 4.5 K. With two distinct spectral modes and tunability through bias current, this amplifier can operate selectively in both the single-mode-amplification regime and the double-mode-amplification regime near the quantum noise limit. Using a nonlinear thin film exhibiting kinetic inductance, our device attains gain exceeding 50 dB in a single-mode configuration and 32 dB in a double-mode configuration, while adding 0.82 input-referred noise quanta. Importantly, this amplifier eliminates the need for Josephson junctions, resulting in the capability to handle significantly higher powers than Josephson junction--based amplifiers. It also demonstrates resilience in the presence of magnetic fields, offers a straightforward design, and increases reliability. This positions the amplifier as a versatile solution for quantum applications and facilitates its integration into future superconducting quantum computers.
A quantum electrometer is proposed which is based on charge modulation of the Josephson supercurrent in the Bloch transistor inserted in a superconducting ring. As this ring is inductively coupled to a high- Q resonance tank circuit, the variations of the charge on the transistor island are converted into variations of amplitude and phase of oscillations in the tank. These variations are amplified and then detected. At sufficiently low temperature of the tank the device sensitivity is determined by the energy resolution of the amplifier, that can be reduced down to the standard quantum limit of 1 / 2Planck's over 2pi. A "back-action-evading" scheme of subquantum limit measurements is proposed.
Superconducting quantum sensors use flux quantization, the Josephson effect and low-loss microwave circuits to measure magnetic flux, microwave signals and photon flux close to fundamental limits. In this review we follow the field from the Bardeen–Cooper–Schrieffer theory and the discovery of Josephson tunnelling to SQUID magnetometers, microwave kinetic inductance detectors and quantum-limited parametric amplifiers. We explain how dc and rf SQUIDs, superconducting resonators, and Josephson and kinetic-inductance amplifiers work, and we describe one measurement chain that covers them all, with separate excitation, response, amplification, control and readout paths and a fluxlocked-loop variant for SQUIDs. Flux and field noise, noise-equivalent power, added noise, bandwidth and dynamic range are defined and compared using numbers taken directly from the primary literature, together with the conditions under which they were measured. We then survey applications in biomagnetism, astronomical imaging, qubit readout and dark-matter searches, and close with the open problems of scalability, environmental noise and fair benchmarking.
Superconducting parametric amplifiers are crucial components in microwave quantum circuits for enabling quantum-limited signal readout.The best-performing such amplifiers are often based on Josephson junctions, which however are sensitive to magnetic fields.Therefore, they require magnetic shields and are not easily integratable with other quantum systems that operate within magnetic fields, such as spinensemble quantum memories.To tackle this challenge, we develop a kinetic inductance-based parametric amplifier featuring a NbN nanobridge instead of Josephson junctions, which provides the desired nonlinearity for a strong parametric gain up to 42 dB.The added noise of this nanobridge kinetic-inductance parametric amplifier (hereby referred to as NKPA) is calibrated and found to be 0.59 ± 0.03 quanta for phase-preserving amplification, approaching the quantum limit of 0.5 quanta.Most importantly, we show that such excellent noise performance is preserved in an in-plane magnetic field up to 427 mT, the maximum field available in our experiment.This magnetic-field-resilient parametric amplifier presents an opportunity towards addressing single electron-spin resonance and more efficient search for axions as well as Majorana fermions.