Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Symposium on Frequency Standards and Metrology

DEVELOPMENT OF AN OPTICAL CLOCKWORK FOR THE SINGLE TRAPPED STRONTIUM ION STANDARD AT 445 THz

J. E. Bernard, P. Dubé, Alan A. Madej, Stan Cundy, J.-S. Boulanger, Jie Jiang, David J. Jones

Published May 1, 2009• 0 citations
Publisher

Abstract

An optical frequency comb, based on a stretched-pulse, mode-locked erbium fibre laser, has been developed to measure the clock transition frequency at 445 THz of a Sr + single-ion optical frequency standard. The comb employs separate amplifier branches for the control of the carrier-envelope offset frequency and for the measurement of the clock frequency of the optical standard. Continous locking periods for the comb of over three days have been observed.

DOI
10.1142/9789812838223_0031

Related papers

Extended precision measurements of a strontium single ion optical frequency standard and its development as an optical atomic clock

Alan A. Madej, P. Dubé, J. E. Bernard +4 more

We describe the recent advances of the NRC single ion based optical frequency standard using the 445-THz S-D transition in88Sr+. Laser cooled confinement and probing of the clock transition has been obtained for periods exceeding 24 hours showing high levels of stability. Spectral resolutions better than 5 Hz at 445 THz have been obtained. Work is described on the development of an improved ion trap system and the continuous linkage of the optical frequency to the RF domain using a fiber based frequency comb.

Conference on Precision Electromagnetic Measurements•Jun 1, 2008•0 citations

Hertz-Level Measurement of the Optical Clock Frequency in a Single 88 Sr + Ion

Helen S. Margolis, G. P. Barwood, Guozheng Huang +4 more

The frequency of the 5s 2S(1/2)-4d 2D(5/2) electric quadrupole clock transition in a single, trapped, laser-cooled 88Sr+ ion has been measured by using an optical frequency comb referenced to a cesium fountain primary frequency standard. The frequency of the transition is measured as 444,779,044,095,484.6 (1.5) hertz, with a fractional uncertainty within a factor of 3 of that of the cesium standard. Improvements required to obtain a cesium-limited frequency measurement are described and are expected to lead to a 88Sr+ optical clock with stability and reproducibility exceeding that of the primary cesium standard.

Science•Nov 18, 2004•301 citations

An Optical Clock Based on a Single Trapped 199 Hg + Ion

Scott A. Diddams, Thomas Udem, Jonas Bergquist +8 more

Microwave atomic clocks have been the de facto standards for precision time and frequency metrology over the past 50 years, finding widespread use in basic scientific studies, communications, and navigation. However, with its higher operating frequency, an atomic clock based on an optical transition can be much more stable. We demonstrate an all-optical atomic clock referenced to the 1.064-petahertz transition of a single trapped 199Hg+ ion. A clockwork based on a mode-locked femtosecond laser provides output pulses at a 1-gigahertz rate that are phase-coherently locked to the optical frequency. By comparison to a laser-cooled calcium optical standard, an upper limit for the fractional frequency instability of 7 x 10(-15) is measured in 1 second of averaging-a value substantially better than that of the world's best microwave atomic clocks.

Science•Aug 3, 2001•727 citations

Subkilohertz comparison of the single-ion optical-clock 2S1/2−2D5/2 transition in two 88Sr+ traps

G. P. Barwood, Guozheng Huang, Hugh A. Klein +2 more

A simultaneous observation of the optical-clock ${}^{2}{S}_{1/2}{\ensuremath{-}}^{2}{D}_{5/2}$ transition at 674 nm, in two separately trapped single ${}^{88}{\mathrm{Sr}}^{+}$ ions, is reported. Two nominally identical miniature rf Paul traps were used together with a 674-nm sideband-injection-locked extended-cavity diode laser. This ``slave'' laser was optically phase locked about 650 MHz away from a ``master'' diode laser, which was itself locked to a high-finesse, ultra-low-expansion (ULE) cavity. The ULE cavity was temperature-stabilized and suspended in an evacuated enclosure, and provided an ``optical flywheel'' reference standard with a relative drift rate of better than 1 part in ${10}^{11}$ per hour. The difference between center frequencies of the single ${}^{88}{\mathrm{Sr}}^{+}$-ion 674-nm (445-THz) transition multiplet in two traps was 120(90) Hz (one standard uncertainty). Thus the two trap center frequencies agree to 3 parts in ${10}^{13}.$

Physical Review A•May 1, 1999•27 citations

Cs-Based Frequency Measurement of a Single, Trapped Ion Transition in the Visible Region of the Spectrum

J. E. Bernard, Alan A. Madej, L. Marmet +3 more

An optical frequency chain referenced to a Cs atomic clock has been used to measure directly the frequency of the electric quadrupole allowed $5s^{2}S_{1/2}\ensuremath{-}4d^{2}D_{5/2}$ transition at 445 THz in a single, trapped, and laser cooled ${}^{88}{\mathrm{Sr}}^{+}$ ion. A transition frequency, ${f}_{S\ensuremath{-}D}\phantom{\rule{0ex}{0ex}}=\phantom{\rule{0ex}{0ex}}444779044095.4\mathrm{kHz}$ with an estimated standard uncertainty of 0.2 kHz has been determined. Intrinsic offsets of the probed ion transition in the current experiment are calculated to be at the ${10}^{\ensuremath{-}15}$ level.

Physical Review Letters•Apr 19, 1999•129 citations

AN OPTICAL CLOCK BASED ON A SINGLE TRAPPED 88 Sr + ION

Helen S. Margolis, G. P. Barwood, G. HUANG +6 more

The 5 s 2 S 1/2 -4 d 2 D 5/2 electric quadrupole transition in a single trapped and laser-cooled 88 Sr + ion provides the reference for a highly stable and accurate optical clock. This paper describes recent progress on the 88 Sr + optical clocks under development at NPL. An ultrastable laser at 674 nm is used to excite the clock transition and a fractional frequency resolution of 2 × 10 -14 has been achieved, corresponding to a linewidth of 9 Hz. A relative frequency instability of 2 × 10 -15 at 5000 s has been observed in the comparison between two similar systems and the fractional uncertainty in the absolute frequency of the clock transition is 3.8 × 10 -15 . Improvements to the experimental arrangement are in progress and are expected to lead to a 88 Sr + optical clock with stability and reproducibility exceeding that of the primary caesium standard.

Symposium on Frequency Standards and Metrology•May 1, 2009•0 citations
An optical frequency comb, based on a stretched-pulse, mode-locked erbium fibre laser, has been developed to measure the clock transition frequency at 445 THz of a Sr + single-ion optical frequency standard. The comb employs separate amplifier branches for the control of the carrier-envelope offset frequency and for the measurement of the clock frequency of the optical standard. Continous locking periods for the comb of over three days have been observed.
We describe the recent advances of the NRC single ion based optical frequency standard using the 445-THz S-D transition in88Sr+. Laser cooled confinement and probing of the clock transition has been obtained for periods exceeding 24 hours showing high levels of stability. Spectral resolutions better than 5 Hz at 445 THz have been obtained. Work is described on the development of an improved ion trap system and the continuous linkage of the optical frequency to the RF domain using a fiber based frequency comb.
The frequency of the 5s 2S(1/2)-4d 2D(5/2) electric quadrupole clock transition in a single, trapped, laser-cooled 88Sr+ ion has been measured by using an optical frequency comb referenced to a cesium fountain primary frequency standard. The frequency of the transition is measured as 444,779,044,095,484.6 (1.5) hertz, with a fractional uncertainty within a factor of 3 of that of the cesium standard. Improvements required to obtain a cesium-limited frequency measurement are described and are expected to lead to a 88Sr+ optical clock with stability and reproducibility exceeding that of the primary cesium standard.
Microwave atomic clocks have been the de facto standards for precision time and frequency metrology over the past 50 years, finding widespread use in basic scientific studies, communications, and navigation. However, with its higher operating frequency, an atomic clock based on an optical transition can be much more stable. We demonstrate an all-optical atomic clock referenced to the 1.064-petahertz transition of a single trapped 199Hg+ ion. A clockwork based on a mode-locked femtosecond laser provides output pulses at a 1-gigahertz rate that are phase-coherently locked to the optical frequency. By comparison to a laser-cooled calcium optical standard, an upper limit for the fractional frequency instability of 7 x 10(-15) is measured in 1 second of averaging-a value substantially better than that of the world's best microwave atomic clocks.
A simultaneous observation of the optical-clock ${}^{2}{S}_{1/2}{\ensuremath{-}}^{2}{D}_{5/2}$ transition at 674 nm, in two separately trapped single 88Sr+{}^{88}{\mathrm{Sr}}^{+}88Sr+ ions, is reported. Two nominally identical miniature rf Paul traps were used together with a 674-nm sideband-injection-locked extended-cavity diode laser. This ``slave'' laser was optically phase locked about 650 MHz away from a ``master'' diode laser, which was itself locked to a high-finesse, ultra-low-expansion (ULE) cavity. The ULE cavity was temperature-stabilized and suspended in an evacuated enclosure, and provided an ``optical flywheel'' reference standard with a relative drift rate of better than 1 part in 1011{10}^{11}1011 per hour. The difference between center frequencies of the single 88Sr+{}^{88}{\mathrm{Sr}}^{+}88Sr+-ion 674-nm (445-THz) transition multiplet in two traps was 120(90) Hz (one standard uncertainty). Thus the two trap center frequencies agree to 3 parts in 1013.{10}^{13}.1013.
An optical frequency chain referenced to a Cs atomic clock has been used to measure directly the frequency of the electric quadrupole allowed $5s^{2}S_{1/2}\ensuremath{-}4d^{2}D_{5/2}$ transition at 445 THz in a single, trapped, and laser cooled 88Sr+{}^{88}{\mathrm{Sr}}^{+}88Sr+ ion. A transition frequency, ${f}_{S\ensuremath{-}D}\phantom{\rule{0ex}{0ex}}=\phantom{\rule{0ex}{0ex}}444779044095.4\mathrm{kHz}$ with an estimated standard uncertainty of 0.2 kHz has been determined. Intrinsic offsets of the probed ion transition in the current experiment are calculated to be at the ${10}^{\ensuremath{-}15}$ level.
The 5 s 2 S 1/2 -4 d 2 D 5/2 electric quadrupole transition in a single trapped and laser-cooled 88 Sr + ion provides the reference for a highly stable and accurate optical clock. This paper describes recent progress on the 88 Sr + optical clocks under development at NPL. An ultrastable laser at 674 nm is used to excite the clock transition and a fractional frequency resolution of 2 × 10 -14 has been achieved, corresponding to a linewidth of 9 Hz. A relative frequency instability of 2 × 10 -15 at 5000 s has been observed in the comparison between two similar systems and the fractional uncertainty in the absolute frequency of the clock transition is 3.8 × 10 -15 . Improvements to the experimental arrangement are in progress and are expected to lead to a 88 Sr + optical clock with stability and reproducibility exceeding that of the primary caesium standard.