Dispersive probing of an atomic transition decreases the "dead time" of optical atomic clocks, potentially enabling more stable time reference standards.
In the mid-20th century, atoms were realized to be good candidates for time or frequency standards since transition energies or frequencies between two energy levels of some unperturbed atoms are more stable than those defined by the rotation of the earth or artefact-based clocks such as quartz crystal clocks. This motivated extensive research on realization and improvement of such kind of quantum-based time or frequency standards. The ultra-stable laser, referred to as a local oscillator in a clock, still drifts over time due to environmentally induced length fluctuations of the reference cavity. With the development of ion traps, ultra-narrow linewidth lasers and optical frequency combs, optical clocks based on single trapped ions as a new type of clocks have been realized in many laboratories. Ions can only stay in the trap within a certain region, which is called stability region. There is a variety of potential sources of systematic shifts associated with the clock transition in ion optical clocks.
Optical atomic clocks play a crucial role in fundamental physics, relativistic geodesy, and the future redefinition of the Systeme International second. Standard operation relies on cyclic interrogation sequences, which alternate between atomic interrogation and dead time used for state preparation and readout. This approach introduces the Dick effect, where laser frequency noise aliases onto the atomic transition frequency. Although reducing laser noise improves clock stability, the Dick effect remains a key limitation. In this Letter, we demonstrate a zero-dead-time optical clock based on two interleaved ensembles of cold ^{87}Sr atoms. Our system significantly suppresses this noise and achieves a fractional frequency instability at the 10^{-19} level between 10 000 and 20 000 s over repeated measurements, with a best value of 2.9×10^{-19} at τ=20000 s. The estimated long-term stability based on the combined data of these measurements reaches 2.5×10^{-19} at 1 day. These results represent a more than ninefold improvement over a conventional single-ensemble clock, highlighting its potential for next-generation timekeeping applications.
Optical single-ion clocks offer a novel way to create a so-called frequency standard, a device for measuring frequencies, with unprecedented accuracy. These standards are often called clocks for simplicity. In recent years, this new approach has been steadily pushing the uncertainty records of atomic clocks well beyond those of more traditional microwave domain implementations. Here, optical clocks refer to atomic clocks where the oscillator of the clock is a laser. In this work, we examine the current state of the VTT MIKES Sr88+ single-ion optical clock and present a new approach to probing the reference ion. The greatest improvement in the systematic uncertainty of the clock has been the new helical resonator, which allows us to trap the ion such that is moves at a so-called ``magic frequency''. At this frequency, motion-related shifts in the reference transition of the ion are minimized. In addition, a bichromatic probing scheme is presented and its stability compared in simulation to a more traditional probing sequence. This new probing sequence is shown to offer an increase in stability in use cases where ion state preparation is not possible. With the simulation, we show that the bichromatic sampling sequence increases the stability of a clock by a factor of 1/\sqrt{2} in the ideal case and a factor of 0.76 in a realistic case, as predicted by theory. To provide a look into the state of the current clock system and near-future upgrades we analyze the results from a 30-hour clock run (continuous operation of the clock) in late 2020. In the clockrun, we reach a stability, as measured by the Allan deviation, extending into the low 10^(-15) range.