Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physics Today

Precision clock traps atoms in light to keep time

Published Feb 18, 2008• 0 citations
Publisher
DOI
10.1063/pt.5.021947

Related papers

Atomic Clock Keeps Super-Cool Time

Science News•Aug 4, 1979•1 citation

Prospects for an atomic clock in a laser trap

E. Abraham, Michael A. Morrison

APS•May 1, 2002•0 citations

Designing a Repump Beam Path for an Optical 171Yb+ Ion Clock

Brian Matthews, Hayden McGuinness

We designed a 935 nm repump beam path for use in a Ytterbium ion based optical clock.This state of the art clock work makes use multiple ensembles of ions trapped in separate RF potentials.Separate beams are amplified for coupling into the chip's integrated waveguides for precision pumping of ions out of dark states.The board acts as both a switch and modulation board.The pump beam is frequency locked to a wavemeter.Two beams are amplified and coupled into the integrated waveguides.The other two beams will be used for free space light delivery.Optical Atomic Clocks: Current atomic cesium clocks count in the range of microwave frequencies with uncertainties approaching 10 -16 [1].Optical atomic clocks based on ultra-stable laser addressing of narrow atomic linewidths achieve frequency uncertainties of ~10 -18 [2].These advanced clocks will impact technologies which rely on precision time keeping such as GPS, computing, and communication.

•Aug 1, 2023•0 citations

Colloquium : Physics of optical lattice clocks

Andrei Derevianko, Hidetoshi Katori

Recently invented and demonstrated optical lattice clocks hold great promise for improving the precision of modern time keeping. These clocks aim at the ${10}^{\ensuremath{-}18}$ fractional accuracy, which translates into a clock that would neither lose nor gain a fraction of a second over an estimated age of the Universe. In these clocks, millions of atoms are trapped and interrogated simultaneously, dramatically improving clock stability. Here the principles of operation of these clocks are discussed and, in particular, a novel concept of magic trapping of atoms in optical lattices. Recently proposed microwave lattice clocks are also highlights and several applications that employ the optical lattice clocks as a platform for precision measurements and quantum information processing.

arXiv:1011.4622•Reviews of Modern Physics•May 3, 2011•267 citations

Atomic clocks using trapped ions

Masatoshi Kajita

Institute of Physics eBooks•Dec 1, 2022•0 citations

Development of an Apparatus for a Strontium Optical Lattice Optical Frequency Standard

Ian R. Hill

Accurate time keeping is critical to the function and advancement of many human endeavours. Atomic clocks based on a microwave transition in atomic Cs have served as primary frequency standards to realise the SI second since their formal adoption in 1967. State-of-the-art, laser cooled, Cs fountains now routinely operate with fractional frequency uncertainties below the 10⁻¹⁵ level in laboratories throughout the world. Over the last decade, efforts to build frequency standards based on optical transitions have come to fruition and potential inaccuracies below the 10⁻¹⁷ level have been demonstrated. Such standards point to the future of time keeping and much development is being pursued to realise the potential of these 'next generation' optical clocks. One such approach, on which this work focusses, relies on a 'magic' wavelength optical lattice trap to provide (almost) Doppler- and recoil-free confinement of atoms during clock interrogation. At this 'magic' wavelength, light induced perturbation of the clock states is equal and so cancels precisely. This thesis describes the design and implementation of an optical lattice frequency standard apparatus based on 88Sr held in a 1D optical lattice. A review of the development of atomic frequency metrology is given from a historical viewpoint and the technology and limitations of current methods discussed. To tackle the blackbody radiation shift, which currently presents the greatest limitation to the Sr lattice clock, imposing at the 10⁻¹⁶ level, a scheme to measure the blackbody radiation shift coefficient at the 10⁻¹⁷ level is developed. Techniques to laser cool and trap atomic strontium are described and the implementation detailed. All laser systems required for clock operation are described including the design and implementation of extended-cavity diode lasers for precision spectroscopy. Details relevant to the eventual operation of the apparatus are discussed.

•Jun 1, 2012•3 citations
We designed a 935 nm repump beam path for use in a Ytterbium ion based optical clock.This state of the art clock work makes use multiple ensembles of ions trapped in separate RF potentials.Separate beams are amplified for coupling into the chip's integrated waveguides for precision pumping of ions out of dark states.The board acts as both a switch and modulation board.The pump beam is frequency locked to a wavemeter.Two beams are amplified and coupled into the integrated waveguides.The other two beams will be used for free space light delivery.Optical Atomic Clocks: Current atomic cesium clocks count in the range of microwave frequencies with uncertainties approaching 10 -16 [1].Optical atomic clocks based on ultra-stable laser addressing of narrow atomic linewidths achieve frequency uncertainties of ~10 -18 [2].These advanced clocks will impact technologies which rely on precision time keeping such as GPS, computing, and communication.
Recently invented and demonstrated optical lattice clocks hold great promise for improving the precision of modern time keeping. These clocks aim at the ${10}^{\ensuremath{-}18}$ fractional accuracy, which translates into a clock that would neither lose nor gain a fraction of a second over an estimated age of the Universe. In these clocks, millions of atoms are trapped and interrogated simultaneously, dramatically improving clock stability. Here the principles of operation of these clocks are discussed and, in particular, a novel concept of magic trapping of atoms in optical lattices. Recently proposed microwave lattice clocks are also highlights and several applications that employ the optical lattice clocks as a platform for precision measurements and quantum information processing.
Accurate time keeping is critical to the function and advancement of many human endeavours. Atomic clocks based on a microwave transition in atomic Cs have served as primary frequency standards to realise the SI second since their formal adoption in 1967. State-of-the-art, laser cooled, Cs fountains now routinely operate with fractional frequency uncertainties below the 10⁻¹⁵ level in laboratories throughout the world. Over the last decade, efforts to build frequency standards based on optical transitions have come to fruition and potential inaccuracies below the 10⁻¹⁷ level have been demonstrated. Such standards point to the future of time keeping and much development is being pursued to realise the potential of these 'next generation' optical clocks. One such approach, on which this work focusses, relies on a 'magic' wavelength optical lattice trap to provide (almost) Doppler- and recoil-free confinement of atoms during clock interrogation. At this 'magic' wavelength, light induced perturbation of the clock states is equal and so cancels precisely. This thesis describes the design and implementation of an optical lattice frequency standard apparatus based on 88Sr held in a 1D optical lattice. A review of the development of atomic frequency metrology is given from a historical viewpoint and the technology and limitations of current methods discussed. To tackle the blackbody radiation shift, which currently presents the greatest limitation to the Sr lattice clock, imposing at the 10⁻¹⁶ level, a scheme to measure the blackbody radiation shift coefficient at the 10⁻¹⁷ level is developed. Techniques to laser cool and trap atomic strontium are described and the implementation detailed. All laser systems required for clock operation are described including the design and implementation of extended-cavity diode lasers for precision spectroscopy. Details relevant to the eventual operation of the apparatus are discussed.