Japanese Journal of Applied Physics

Absorption of Rb-D Limes by Rb Filter Cell

Toshiharu Tako, Y. Koga, Isao Hirano, Misao Ohi

Published Nov 1, 1975• 9 citations
Publisher

Abstract

The effects of absorption of Rb-D lines are studied with the combination of natural Rb lamps and natural Rb filter cells containing nitrogen at the pressures of 100 Tori and 152 Torr. It is found that the hyperfine components of D lines effective for optical pumping is obtained with Rb atoms of natural abundance both for lamps and for cells. The optimum temperature of the filter cell is observed to be near at 60°C. The absorption coefficient of the filter cell is less than 1.5 cm -1 . The absorption cross sections obtained for three broad peaks consisting of hyper finecomponents are measured to be 10 -12 ∼10 -13 cm 2 , which is 10 2 ∼10 3 times larger than the atomic cross section of Rb in its ground state. The absorption cross sections for the filter cell with N 2 100 Torr have values a few times larger than those for the filter cell with N 2 152 Torr.

DOI
10.1143/jjap.14.1641

Related papers

Spectral Profiles of the87Rb Pumping Light Source

Naimu Kuramochi, Hitohiro Fukuyo, Isao Matsuda +1 more

This paper is concerned with experimental studies of the 87 Rb pumping light source, which is composed of a 87 Rb lamp and a 85 Rb filter cell. Spectral profiles of the pumping light were observed by means of a Fabry-Perot interferometer. Measurements were executed by using ten filter cells which contained 85 Rb atoms and various gases (N 2 , Ar and He) under various pressures. As a result, it became clear that the change of the pumping light spectrum with the filter cell temperature was specific to each cell. When we took note of the ratio and the difference of the two components of Rb D 1 line as measures of the filtering effect, the temperature dependence of these values relied on the kind and the pressure of the foreign gas.

Japanese Journal of Applied Physics•Jun 1, 1976•8 citations

Composite-type ^87Rb optical-pumping light source

Naimu Kuramochi, Shigeya Naritsuka, N. Oura

A (87)Rb hyperfine optical-pumping light source less than 4 cm long has been fabricated. Features of this new light source are: A 3-7-mm-long (85)Rb filter cell is attached to the front face of a cylindrical (87)Rb lamp with a diameter of 10mm, and both the lamp and the filter cell are operated at the same temperature of about 100 degrees C. A satisfactory spectral profile of D(1)-line output (lambda = 794.8 nm) has been observed by using a Fabry-Perot interferometer.

Optics Letters•Feb 1, 1981•2 citations

高圧ガスを封じた^ Rbセルの^ Rbランプ光に対するフィルタ効果

勲 松田, 近藤 義一, 内武 倉持 +4 more

Spectral profiles of the ^<87>Rb D_1 line (λ=794.8 nm) passed through the cell are calculated to evaluate the filtering effect. Upon the calculatio, the broadening and shift of the pronle due to high pressure foreign gas are taken into account to make the cell absorb the unwanted spectral components emitted from the lamp. Filtering effect is discussed on the ^<87>Rb cell containing a pressure of 300 to 900 Torr of N_2 or He gas.

東京工芸大学工学部紀要•Jan 1, 1982•0 citations

Analysis of the effect of foreign gases in the filtering action of a ^85Rb cell

Naimu Kuramochi, Isao Matsuda, Hitohiro Fukuyo

The variation in the 87Rb D1 (λ = 794.8 nm) pumping light profiles due to 85Rb filter cell temperatures (< 80 °C) has been explained by considering both the shift and broadening of the 85Rb absorption spectrum caused by low-pressure foreign gases (< 200 Torr). The coefficients of the pressure shift and broadening by N2 gas were obtained as −8.0 ± 0.5 and 11 ± 1 MHz/Torr, respectively. The intensity ratio and difference of two peaks in the profiles were calculated in order to discuss the variation in the profiles quantitatively. The foreign gas He was examined for comparison. The absorption coefficient of Rb was also discussed.

Journal of the Optical Society of America•Aug 1, 1978•13 citations

An Interferometric Technique Of Density Measurement Applied To Alkali-metal Vapors Oriented By Optical Pumping.

Steven Jarrett

III-8.Comparison of optical pumping signals for two spherical cells with different buffer gas pressures as a function of density times diameter of cell for equal D2/D1.60 IV-1.Energy level diagram showing hyperfine structure of Rb Di line.Units are 10*3 cm-1.67 IV-2.Equivalent circuit for rate equations involving ex change polarization.73 IV-3.Diagram of optical system for optical pumping of Rb. 83 IV-4.Block diagram of Rb optical pumping signal detection system.85 IV-5.Block diagram of Rb light detection system.90 IV-6.Typical photograph from which relaxation time measure ments are made..Time increases from left to right.Scale is 1 millisecond per division.92 IV-7.Lines determined from measurements on time dependence of Rb87 signals at 50°C for the two different light in tensities.Scatter of points is too small to be notice able on graph.93 A-1.Spectral profile of D1 radiation from a Varian spectral lamp containing natural Rb.Ill A-2.Spectral profile of Di radiation from a Varian spectral lamp containing Rb87.112 A-3-Spectral profile of Di radiation from a Varian spectral lamp containing Rb87 after filtering by an Rb85 absorption cell.113 vi CHAPTER I2 atomic ground states and the parameters of various relaxation processes of gaseous systems.These investigations led to the development of mag netometers of unique sensitivity.More recently, very precise frequency standards have been developed using the methods of optical pumping and the knowledge gained through their application.The present work was undertaken in the context of extending our knowledge of the dynamics of optical pumping methods and of exploiting these methods for the deter mination of an interesting atomic exchange cross section.Optical pumping may be considered as a specialized technique used in conjunction with magnetic resonance phenomena.All magnetic reso nance techniques depend upon obtaining an oriented (polarized) macro scopic sample of matter, that is, matter with a net magnetic moment.In the atomic beam magnetic resonance method, this is accomplished by sort ing out, spatially, atoms whose magnetic moments have a particular ori entation with respect to a magnetic field.In nuclear or electron para magnetic resonance work in solids, liquids, or gases, the small thermal equilibrium polarization that matter possesses in a magnetic field is exploited.Optical pumping enhances this equilibrium polarization through selective optical absorption, by a gaseous atomic system, of polarized resonance radiation.Optical pumping offers the great advan tage of experimental simplicity, as compared to other magnetic resonance techniques, but suffers from severe limitations in application.Since the original suggestion by Brossel and Nastier^ and subse quent development by many others, optical pumping, in conjunction with the transmission monitoring technique of signal detection, has became a standard technique in the study of alkali metal ground states.By far the greatest amount of work in optical pumping has been concerned with alkali metal vapors.Bell, Bloom/ and others^ have considered the process of the optical pumping of the alkalis with attention to the spec tral composition of the pumping light, that is, the resonance radiation incident on the alkali vapor.Colegrove and Franken? have recently dis cussed the complication in the analyses of optical pumping signals for Q helium when the helium absorption cell is optically thick.Hobart has considered this same complication for sodium.Prediction of signals must take into account the fact that the pumping light is absorbed ap proximately exponentially in the optical pumping absorption cell.This means that the absorption coefficient, which is proportional to the al kali density, times the length of the cell is a significant parameter in determining the strength of the signal.Similar calculations of the dependence of optical pumping signals on alkali density and spectral com position of the pumping light will be presented in this work.In order to test the signal predictions> a high resolution Fabry-Perot spectrometer was constructed.This instrument can be used for two purposes : the investigation of the intensity distribution of the pumping light, and, more importantly, determinations of the alkali vapor density in the absorption cell.The desired data are curves of optical pumping signals, for a typical sodium optical pumping experiment, as a function of density.It is often necessary to know these densities in order to is limited to the accuracy to which the density is known.Since the Fabry-Perot spectrometer used to measure sodium vapor densities in conjunction with the signal strength versus density meas urements can be applied to different systems, it was decided to make a determination of the rubidium 85-rubidium 87 spin exchange cross sec tion.The reasons for this choice are discussed in detail in Chapt.IV.In brief, work on rubidium exchange offered some experimental sim plifications and rubidium has previously been studied more thoroughly than other systems.

•Jan 1, 1963•0 citations

Temperature Dependence of Hyperfine Spectrum of Rb D1Line

Hitohiro Fukuyo, Kenichi Iga, Naimu Kuramochi +1 more

This paper deals with the experimental studies of the rubidium (Rb) spectral lamp for the purpose of getting an excellent pumping light source for a Rb gas cell type frequency standard, or for a Rb microwave maser. Some of Rb lamps containing Ne, Ar, Kr, and Ne-Ar as a carrier gas were made by way of experiment. In order to observe the hyperfine spectrum of D1line, the Fabry-Perot type scanning interferometer was made, which is driven electrostrictively. The hyperfine components of D1line were resolved successfully. It was observed that the line which is used as a pumping source became intense as the lamp temperature was raised, and it began to be dipped and decrease, however, over the definite temperature. Also observed was that this optimum temperature differs from the temperature at which the integrated intensity of D1line shows a maximum.

Japanese Journal of Applied Physics•Jul 1, 1970•8 citations
The effects of absorption of Rb-D lines are studied with the combination of natural Rb lamps and natural Rb filter cells containing nitrogen at the pressures of 100 Tori and 152 Torr. It is found that the hyperfine components of D lines effective for optical pumping is obtained with Rb atoms of natural abundance both for lamps and for cells. The optimum temperature of the filter cell is observed to be near at 60°C. The absorption coefficient of the filter cell is less than 1.5 cm -1 . The absorption cross sections obtained for three broad peaks consisting of hyper finecomponents are measured to be 10 -12 ∼10 -13 cm 2 , which is 10 2 ∼10 3 times larger than the atomic cross section of Rb in its ground state. The absorption cross sections for the filter cell with N 2 100 Torr have values a few times larger than those for the filter cell with N 2 152 Torr.
This paper is concerned with experimental studies of the 87 Rb pumping light source, which is composed of a 87 Rb lamp and a 85 Rb filter cell. Spectral profiles of the pumping light were observed by means of a Fabry-Perot interferometer. Measurements were executed by using ten filter cells which contained 85 Rb atoms and various gases (N 2 , Ar and He) under various pressures. As a result, it became clear that the change of the pumping light spectrum with the filter cell temperature was specific to each cell. When we took note of the ratio and the difference of the two components of Rb D 1 line as measures of the filtering effect, the temperature dependence of these values relied on the kind and the pressure of the foreign gas.
The variation in the 87Rb D1 (λ = 794.8 nm) pumping light profiles due to 85Rb filter cell temperatures (< 80 °C) has been explained by considering both the shift and broadening of the 85Rb absorption spectrum caused by low-pressure foreign gases (< 200 Torr). The coefficients of the pressure shift and broadening by N2 gas were obtained as −8.0 ± 0.5 and 11 ± 1 MHz/Torr, respectively. The intensity ratio and difference of two peaks in the profiles were calculated in order to discuss the variation in the profiles quantitatively. The foreign gas He was examined for comparison. The absorption coefficient of Rb was also discussed.
III-8.Comparison of optical pumping signals for two spherical cells with different buffer gas pressures as a function of density times diameter of cell for equal D2/D1.60 IV-1.Energy level diagram showing hyperfine structure of Rb Di line.Units are 10*3 cm-1.67 IV-2.Equivalent circuit for rate equations involving ex change polarization.73 IV-3.Diagram of optical system for optical pumping of Rb. 83 IV-4.Block diagram of Rb optical pumping signal detection system.85 IV-5.Block diagram of Rb light detection system.90 IV-6.Typical photograph from which relaxation time measure ments are made..Time increases from left to right.Scale is 1 millisecond per division.92 IV-7.Lines determined from measurements on time dependence of Rb87 signals at 50°C for the two different light in tensities.Scatter of points is too small to be notice able on graph.93 A-1.Spectral profile of D1 radiation from a Varian spectral lamp containing natural Rb.Ill A-2.Spectral profile of Di radiation from a Varian spectral lamp containing Rb87.112 A-3-Spectral profile of Di radiation from a Varian spectral lamp containing Rb87 after filtering by an Rb85 absorption cell.113 vi CHAPTER I2 atomic ground states and the parameters of various relaxation processes of gaseous systems.These investigations led to the development of mag netometers of unique sensitivity.More recently, very precise frequency standards have been developed using the methods of optical pumping and the knowledge gained through their application.The present work was undertaken in the context of extending our knowledge of the dynamics of optical pumping methods and of exploiting these methods for the deter mination of an interesting atomic exchange cross section.Optical pumping may be considered as a specialized technique used in conjunction with magnetic resonance phenomena.All magnetic reso nance techniques depend upon obtaining an oriented (polarized) macro scopic sample of matter, that is, matter with a net magnetic moment.In the atomic beam magnetic resonance method, this is accomplished by sort ing out, spatially, atoms whose magnetic moments have a particular ori entation with respect to a magnetic field.In nuclear or electron para magnetic resonance work in solids, liquids, or gases, the small thermal equilibrium polarization that matter possesses in a magnetic field is exploited.Optical pumping enhances this equilibrium polarization through selective optical absorption, by a gaseous atomic system, of polarized resonance radiation.Optical pumping offers the great advan tage of experimental simplicity, as compared to other magnetic resonance techniques, but suffers from severe limitations in application.Since the original suggestion by Brossel and Nastier^ and subse quent development by many others, optical pumping, in conjunction with the transmission monitoring technique of signal detection, has became a standard technique in the study of alkali metal ground states.By far the greatest amount of work in optical pumping has been concerned with alkali metal vapors.Bell, Bloom/ and others^ have considered the process of the optical pumping of the alkalis with attention to the spec tral composition of the pumping light, that is, the resonance radiation incident on the alkali vapor.Colegrove and Franken? have recently dis cussed the complication in the analyses of optical pumping signals for Q helium when the helium absorption cell is optically thick.Hobart has considered this same complication for sodium.Prediction of signals must take into account the fact that the pumping light is absorbed ap proximately exponentially in the optical pumping absorption cell.This means that the absorption coefficient, which is proportional to the al kali density, times the length of the cell is a significant parameter in determining the strength of the signal.Similar calculations of the dependence of optical pumping signals on alkali density and spectral com position of the pumping light will be presented in this work.In order to test the signal predictions> a high resolution Fabry-Perot spectrometer was constructed.This instrument can be used for two purposes : the investigation of the intensity distribution of the pumping light, and, more importantly, determinations of the alkali vapor density in the absorption cell.The desired data are curves of optical pumping signals, for a typical sodium optical pumping experiment, as a function of density.It is often necessary to know these densities in order to is limited to the accuracy to which the density is known.Since the Fabry-Perot spectrometer used to measure sodium vapor densities in conjunction with the signal strength versus density meas urements can be applied to different systems, it was decided to make a determination of the rubidium 85-rubidium 87 spin exchange cross sec tion.The reasons for this choice are discussed in detail in Chapt.IV.In brief, work on rubidium exchange offered some experimental sim plifications and rubidium has previously been studied more thoroughly than other systems.
This paper deals with the experimental studies of the rubidium (Rb) spectral lamp for the purpose of getting an excellent pumping light source for a Rb gas cell type frequency standard, or for a Rb microwave maser. Some of Rb lamps containing Ne, Ar, Kr, and Ne-Ar as a carrier gas were made by way of experiment. In order to observe the hyperfine spectrum of D1line, the Fabry-Perot type scanning interferometer was made, which is driven electrostrictively. The hyperfine components of D1line were resolved successfully. It was observed that the line which is used as a pumping source became intense as the lamp temperature was raised, and it began to be dipped and decrease, however, over the definite temperature. Also observed was that this optimum temperature differs from the temperature at which the integrated intensity of D1line shows a maximum.