Japanese Journal of Applied Physics

Development of Phase-lock System between Two Single-Mode Lasers for Optical-Optical Double Resonance Spectroscopy

Motohiro Kumagai, Hideto Kanamori, Michio M. Matsushita, Tatsuhisa Kato

Published Oct 1, 1999• 6 citations
Publisher

Abstract

The difference frequency between two single-mode CW lasers was stabilized to a microwave (MW) frequency reference by using an optical phase-lock loop (PLL). The long-term frequency jittering of the beat spectrum was much suppressed by this method. The difference frequency was able to be continuously scanned from 0.1 to 18 GHz by changing the microwave reference frequency. It was also possible to scan the two lasers synchronously keeping the difference frequency constant. This stable and flexible light source would be an ideal light source for optical-optical double resonance (OODR) spectroscopy and resonance laser Raman experiments. For the demonstration, this new system was applied to an OODR experiment using a Rubidium atom. The hyperfine structures in the D2line were observed in the sub-Doppler condition.

DOI
10.1143/jjap.38.6102

Related papers

Experiment of Laser Phase Lock with Source Locking CW Microwave Frequency Counter

Jing Zhang

Technology of achieving stable laser frequency plays an important role in the application of high precision measurement and high fine spectrum.In this paper,we phase-locked a laser for 3 to 4 hours to the other laser by the signal of beat frequency between two lasers,based on the instrument:Source locking CW microwave frequency counter.This work enables us to investigate the electromagnetically induced transparency spectroscopy,Raman spectroscopy and four-wave-mixing in atomic system.

Journal of Shanxi University•Jan 1, 2012•0 citations

Production of a coherent pair of light beams with a microwave frequency difference from a single extended-cavity diode laser

Sin Hyuk Yim, D. Cho

We produced a pair of coherent laser beams with a 3-GHz frequency difference by optically phase locking two modes from a single, multimode extended-cavity diode laser. This method is complementary to either a direct modulation or an optical phase locking of two independent lasers. A large differential frequency shift between the two modes of the laser allows efficient phase locking. We developed a simple theory to account for the large differential frequency shift. Allan deviation of the beat frequency when the two modes are phase-locked drops as an inverse of the measurement time and it reaches 10(-14) when the time is 1 h. Coherent population trapping spectroscopy of Rb atoms using the phase-locked beams resulted in a spectrum as narrow as that of the case using direct modulation by a stable frequency synthesizer.

Review of Scientific Instruments•Feb 1, 2010•6 citations

Frequency stabilization of a GaAs semiconductor laser by use of the optical-optical double-resonance effect of the Doppler-free spectrum of Rb D/sub 1/ line

Masao Suzuki, S. Yamaguchi

The frequency of a GaAs semiconductor laser was locked to the hyperfine spectrum of the Rb D/sub 1/ line by saturation spectroscopy. A first GaAs laser was locked to one of the Doppler-free hyperfine lines using a source modulation method. The burnt hole modulated by the stabilized laser beam was detected by a second laser beam irradicated from the same or the opposite direction and was used as a frequency discriminator to stabilize the second laser. The characteristics of the double-resonance spectrum were measured. The frequency stability of the second laser, which was free from frequency modulation, was estimated to be on the order of 10/sup -9/.>

IEEE Journal of Quantum Electronics•Dec 1, 1988•12 citations

A versatile digital GHz phase lock for external cavity diode lasers

J. Appel, Andrew MacRae, Alexander I. Lvovsky

We present a versatile, inexpensive and simple optical phase lock for applications in atomic physics experiments. Thanks to all-digital phase detection and implementation of beat frequency pre-scaling, the apparatus requires no microwave-range reference input, and permits phase locking at frequency differences ranging from sub-MHz to 7 GHz (and with minor extension, to 12 GHz). The locking range thus covers ground state hyperfine splittings of all alkali metals, which makes this system a universal tool for many experiments on coherent interaction between light and atoms.

arXiv:0809.3607•Measurement Science and Technology•Apr 17, 2009•87 citations

Laser frequency offset locking using electromagnetically induced transparency

S. C. Bell, D. Heywood, J. D. White +2 more

The authors have used an electromagnetically induced transparency resonance in rubidium as a dispersive reference to lock the relative frequency of two lasers to the atomic ground-state hyperfine splitting. The beat frequency between the two lasers directly generates a microwave signal at 3.036GHz (Rb85) or 6.835GHz (Rb87). High bandwidth (600kHz) feedback was achieved with only low-frequency (10MHz) electronics using the frequency modulation sideband method. The spectral width of the microwave beat frequency was reduced to less than 1kHz. The technique offers a convenient and low-cost method suitable for many topical two-frequency experiments, including coherent population trapping, slow light, lasing without inversion, and Raman sideband cooling.

Applied Physics Letters•Apr 23, 2007•63 citations

Doppler-free modulation transfer spectroscopy of rubidium 52S1/2–62P1/2 transitions using a frequency-doubled diode laser blue-light source

Nobuhiko Ito

A frequency-doubled diode laser spectrometer in the blue-wavelength region with a continuous-frequency tuning range of up to ∼7 GHz has been developed, comprising a powerful fundamental light source based on a master/slave laser combination coupled with a KNbO3 crystal for second-harmonic generation in a power-enhancement cavity. It has been employed for the observation of saturated absorption spectra in 52S1/2–62P1/2 hyperfine transitions of atomic rubidium with the aid of a modulation transfer spectroscopic technique, and also the frequency stabilization to one of them has been demonstrated, suggesting the possibility of the establishment of a precision optical frequency marker in the blue range. A relative stability of better than 2.8×10−10 is estimated based on the locked error signal in the preliminary stabilization. With a further study of the frequency instability and uncertainty, in addition to supplementary improvements of apparatus, one may expect a realization of a stabilized laser in the blue-spectral domain. Details of the developed blue-light source are described and the demonstrated results of the rubidium spectroscopy are also described and discussed.

Review of Scientific Instruments•Jul 1, 2000•27 citations
The difference frequency between two single-mode CW lasers was stabilized to a microwave (MW) frequency reference by using an optical phase-lock loop (PLL). The long-term frequency jittering of the beat spectrum was much suppressed by this method. The difference frequency was able to be continuously scanned from 0.1 to 18 GHz by changing the microwave reference frequency. It was also possible to scan the two lasers synchronously keeping the difference frequency constant. This stable and flexible light source would be an ideal light source for optical-optical double resonance (OODR) spectroscopy and resonance laser Raman experiments. For the demonstration, this new system was applied to an OODR experiment using a Rubidium atom. The hyperfine structures in the D2line were observed in the sub-Doppler condition.
We produced a pair of coherent laser beams with a 3-GHz frequency difference by optically phase locking two modes from a single, multimode extended-cavity diode laser. This method is complementary to either a direct modulation or an optical phase locking of two independent lasers. A large differential frequency shift between the two modes of the laser allows efficient phase locking. We developed a simple theory to account for the large differential frequency shift. Allan deviation of the beat frequency when the two modes are phase-locked drops as an inverse of the measurement time and it reaches 10(-14) when the time is 1 h. Coherent population trapping spectroscopy of Rb atoms using the phase-locked beams resulted in a spectrum as narrow as that of the case using direct modulation by a stable frequency synthesizer.
The frequency of a GaAs semiconductor laser was locked to the hyperfine spectrum of the Rb D/sub 1/ line by saturation spectroscopy. A first GaAs laser was locked to one of the Doppler-free hyperfine lines using a source modulation method. The burnt hole modulated by the stabilized laser beam was detected by a second laser beam irradicated from the same or the opposite direction and was used as a frequency discriminator to stabilize the second laser. The characteristics of the double-resonance spectrum were measured. The frequency stability of the second laser, which was free from frequency modulation, was estimated to be on the order of 10/sup -9/.>
We present a versatile, inexpensive and simple optical phase lock for applications in atomic physics experiments. Thanks to all-digital phase detection and implementation of beat frequency pre-scaling, the apparatus requires no microwave-range reference input, and permits phase locking at frequency differences ranging from sub-MHz to 7 GHz (and with minor extension, to 12 GHz). The locking range thus covers ground state hyperfine splittings of all alkali metals, which makes this system a universal tool for many experiments on coherent interaction between light and atoms.
The authors have used an electromagnetically induced transparency resonance in rubidium as a dispersive reference to lock the relative frequency of two lasers to the atomic ground-state hyperfine splitting. The beat frequency between the two lasers directly generates a microwave signal at 3.036GHz (Rb85) or 6.835GHz (Rb87). High bandwidth (600kHz) feedback was achieved with only low-frequency (10MHz) electronics using the frequency modulation sideband method. The spectral width of the microwave beat frequency was reduced to less than 1kHz. The technique offers a convenient and low-cost method suitable for many topical two-frequency experiments, including coherent population trapping, slow light, lasing without inversion, and Raman sideband cooling.
A frequency-doubled diode laser spectrometer in the blue-wavelength region with a continuous-frequency tuning range of up to ∼7 GHz has been developed, comprising a powerful fundamental light source based on a master/slave laser combination coupled with a KNbO3 crystal for second-harmonic generation in a power-enhancement cavity. It has been employed for the observation of saturated absorption spectra in 52S1/2–62P1/2 hyperfine transitions of atomic rubidium with the aid of a modulation transfer spectroscopic technique, and also the frequency stabilization to one of them has been demonstrated, suggesting the possibility of the establishment of a precision optical frequency marker in the blue range. A relative stability of better than 2.8×10−10 is estimated based on the locked error signal in the preliminary stabilization. With a further study of the frequency instability and uncertainty, in addition to supplementary improvements of apparatus, one may expect a realization of a stabilized laser in the blue-spectral domain. Details of the developed blue-light source are described and the demonstrated results of the rubidium spectroscopy are also described and discussed.