Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Japanese Journal of Applied Physics

Pulse Excitation Method of Coherent-Population-Trapping Suitable for Chip-Scale Atomic Clock

Yuichiro Yano, Shigeyoshi Goka

Published Nov 9, 2012• 12 citations
Publisher

Abstract

We propose a pulse excitation method of coherent population trapping (CPT) with a liquid crystal optical modulator. Since liquid crystals enable reductions in size, weight, cost, and power consumption compared with acousto-optical modulators (AOMs), our method is suitable for chip-scale atomic clocks (CSACs). Experiments showed that pulse excitation with a liquid crystal modulator can narrow the CPT resonance linewidth and reduce the light shift effect using a 87Rb gas cell and the D1-line vertical-cavity surface-emitting laser (VCSEL). The CPT resonance linewidth and light shift sensitivity were less than one-eighth and one-third those for continuous excitation, respectively. They also showed that our method is comparable to that based on an AOM.

DOI
10.7567/jjap.51.122401

Related papers

CPT pulse excitation method based on VCSEL current modulation for miniature atomic clocks

Takumi Ide, Shigeyoshi Goka, Yuichiro Yano

We propose a coherent population trapping (CPT) pulsed-excitation method based on direct drive-current modulation of a vertical-cavity surface-emitting LASER for miniature atomic clocks (MACs). Because our method needs only a simple device configuration without optical external modulators, it is suitable for MACs, including chip-scale atomic-clocks. Reducing the size, cost, and power consumption is also possible. Additionally, we report on experimental results for Ramsey-CPT fringes excited using the proposed method.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2015•11 citations

Exploring Ramsey-coherent population trapping atomic clock realized with pulsed microwave modulated laser

Jing Yang, Yuan Tian, Bozhong Tan +2 more

A scheme for a Ramsey-coherent population trapping (CPT) atomic clock that eliminates the acousto-optic modulator (AOM) is proposed and experimentally studied. Driven by a periodically microwave modulated current, the vertical-cavity surface-emitting laser emits a continuous beam that switches between monochromatic and multichromatic modes. Ramsey-CPT interference has been studied with this mode-switching beam. In eliminating the AOM, which is used to generate pulsed laser in conventional Ramsey-CPT atomic clock, the physics package of the proposed scheme is virtually the same as that of a conventional compact CPT atomic clock, although the resource budget for the electronics will slightly increase as a microwave switch should be added. By evaluating and comparing experimentally recorded signals from the two Ramsey-CPT schemes, the short-term frequency stability of the proposed scheme was found to be 46% better than the scheme with AOM. The experimental results suggest that the implementation of a compact Ramsey-CPT atomic clock promises better frequency stability.

Journal of Applied Physics•Mar 7, 2014•16 citations

CPT chip-scale atomic clock with direct-modulation chip-external cavity diode laser

Jiqing Lian, Jie Miao, Tian Zhao +7 more

Chip-scale atomic clocks are critical for applications requiring compact, energy-efficient, and highly stable timing, such as GPS receivers and communication systems. Coherent population trapping (CPT)-based atomic clocks, which commonly use vertical-cavity surface-emitting lasers (VCSELs), have enabled significant miniaturization. However, their precision is limited by the broad linewidth of VCSELs. Alternative laser technologies, such as distributed Bragg reflector lasers, distributed feedback lasers, and external cavity diode lasers (ECDLs), offer potential improvements but face challenges in achieving compact size and adequate modulation bandwidth. This study presents a 795 nm chip-ECDL with a direct modulation bandwidth up to 4 GHz, specifically designed for CPT chip-scale atomic clocks. Based on the chip-ECDL, a CPT atomic clock with a compact volume of 19.4 ml and power consumption of 1.5 W has been developed. Under identical operating conditions, the CPT signal produced by the chip-ECDL exhibits a 34% reduction in linewidth and a 1.14-fold increase in contrast compared to a VCSEL-based clock. Demonstrating short-term stability better than 5×10−11τ−1/2(1 s<τ<2000 s) and reaching a best stability of 6.6×10−13 at 2000 s, this work represents the application of an ECDL in a CPT chip-scale clock, advancing the development of next-generation, high-performance chip-scale atomic clocks.

Applied Physics Letters•Jun 2, 2025•11 citations

Exploring Ramsey-CPT spectroscopy in a microcell atomic clock

Clément Carlé, Petersen, Michael, Nicolas Passilly +2 more

Chip-scale atomic clocks (CSACs) based on coherent population trapping (CPT) have attracted significant research and development efforts due to their unrivaled size-power-stability budget [1]. In such clocks, the continuous-wave (CW) interaction of atoms with light yields power broadening and a significant sensitivity of the clock frequency to light-shift effects that contribute to the clock mid-term and long-term stability budget. Numerous approaches have been demonstrated in the literature to reduce light-shift effects in CW-CPT clocks [2-6]. In this study, using an external acousto-optic modulator to produce the interrogation sequence, we investigate the use of Ramsey-CPT spectroscopy in a buffer-gas filled microcell atomic clock. Some results are compared with those obtained in the standard CW regime. In the Ramsey-CPT case, the clock frequency dependence to laser power is reduced by a factor of 60 with a dark time T of 450 µs, at the expense of a 3 times higher operation power. The sensitivity to microwave power variations is reduced by a factor higher than 2. The Ramsey-CPT interrogation improves the clock Allan deviation for time scales in the 100-10 4 s range, at the expense of a degraded short-term stability when the dark time T is increased too much. A clock frequency stability of 3.8 × 10 −12 at 10 4 s is obtained with T = 450 µs, in comparison with the level of 8 × 10 −11 obtained in the standard CW case, in similar experimental conditions and the same cell. These results suggest that Ramsey-based interrogation protocols might be an attractive approach for the development of CSACs with enhanced mid-and long-term stability.

•Mar 22, 2021•0 citations

Coherent Population Trapped Spectrum Based on Chip-Scale External Cavity Diode Laser

Tian Zhao, Jiqing Lian, S.K. Wu +5 more

This article reports a scheme for obtaining coherent population trapping (CPT) spectrum based on a chip-scale external cavity diode laser (CECDL). The CPT spectrum linewidth is 680Hz. Compared to the scheme using vertical cavity surface emitting laser (VCSEL), CECDL has a comparable small volume and higher laser power of 14mW and narrower linewidth of 270kHz. This is beneficial for improving the frequency stability performance of CPT chip-scale atomic clocks.

European Frequency and Time Forum•Jun 25, 2024•2 citations

Ramsey-CPT spectroscopy for a microcell atomic clock

Clément Carlé, Petersen, Michael, Nicolas Passilly +3 more

We investigate the use of pulsed Ramsey-CPT spectroscopy in a coherent population trapping (CPT) atomic clock using a microfabricated buffer gas-filled Cs vapor cell. Tests are performed on a table-top setup with an external acousto-optical modulator (AOM) to produce the optical CPT pulse sequence. A relevant reduction of the clock frequency sensitivity to laser power variations by a factor of about 40 is observed, in comparison with the standard continuous-wave (CW) regime, with a free-evolution time T = 450 μs. The dependence to microwave power variations is also reduced in the Ramsey-CPT interrogation case. With the same cell physics package and similar environmental conditions, the clock Allan deviation is clearly improved for time scales higher than 100 s in the Ramsey-CPT case. These results suggest that the use of Ramsey spectroscopy might be an attractive approach in miniature clocks

•Jul 7, 2021•0 citations
We propose a pulse excitation method of coherent population trapping (CPT) with a liquid crystal optical modulator. Since liquid crystals enable reductions in size, weight, cost, and power consumption compared with acousto-optical modulators (AOMs), our method is suitable for chip-scale atomic clocks (CSACs). Experiments showed that pulse excitation with a liquid crystal modulator can narrow the CPT resonance linewidth and reduce the light shift effect using a 87Rb gas cell and the D1-line vertical-cavity surface-emitting laser (VCSEL). The CPT resonance linewidth and light shift sensitivity were less than one-eighth and one-third those for continuous excitation, respectively. They also showed that our method is comparable to that based on an AOM.
We propose a coherent population trapping (CPT) pulsed-excitation method based on direct drive-current modulation of a vertical-cavity surface-emitting LASER for miniature atomic clocks (MACs). Because our method needs only a simple device configuration without optical external modulators, it is suitable for MACs, including chip-scale atomic-clocks. Reducing the size, cost, and power consumption is also possible. Additionally, we report on experimental results for Ramsey-CPT fringes excited using the proposed method.
A scheme for a Ramsey-coherent population trapping (CPT) atomic clock that eliminates the acousto-optic modulator (AOM) is proposed and experimentally studied. Driven by a periodically microwave modulated current, the vertical-cavity surface-emitting laser emits a continuous beam that switches between monochromatic and multichromatic modes. Ramsey-CPT interference has been studied with this mode-switching beam. In eliminating the AOM, which is used to generate pulsed laser in conventional Ramsey-CPT atomic clock, the physics package of the proposed scheme is virtually the same as that of a conventional compact CPT atomic clock, although the resource budget for the electronics will slightly increase as a microwave switch should be added. By evaluating and comparing experimentally recorded signals from the two Ramsey-CPT schemes, the short-term frequency stability of the proposed scheme was found to be 46% better than the scheme with AOM. The experimental results suggest that the implementation of a compact Ramsey-CPT atomic clock promises better frequency stability.
Chip-scale atomic clocks are critical for applications requiring compact, energy-efficient, and highly stable timing, such as GPS receivers and communication systems. Coherent population trapping (CPT)-based atomic clocks, which commonly use vertical-cavity surface-emitting lasers (VCSELs), have enabled significant miniaturization. However, their precision is limited by the broad linewidth of VCSELs. Alternative laser technologies, such as distributed Bragg reflector lasers, distributed feedback lasers, and external cavity diode lasers (ECDLs), offer potential improvements but face challenges in achieving compact size and adequate modulation bandwidth. This study presents a 795 nm chip-ECDL with a direct modulation bandwidth up to 4 GHz, specifically designed for CPT chip-scale atomic clocks. Based on the chip-ECDL, a CPT atomic clock with a compact volume of 19.4 ml and power consumption of 1.5 W has been developed. Under identical operating conditions, the CPT signal produced by the chip-ECDL exhibits a 34% reduction in linewidth and a 1.14-fold increase in contrast compared to a VCSEL-based clock. Demonstrating short-term stability better than 5×10−11τ−1/2(1 s<τ<2000 s) and reaching a best stability of 6.6×10−13 at 2000 s, this work represents the application of an ECDL in a CPT chip-scale clock, advancing the development of next-generation, high-performance chip-scale atomic clocks.
Chip-scale atomic clocks (CSACs) based on coherent population trapping (CPT) have attracted significant research and development efforts due to their unrivaled size-power-stability budget [1]. In such clocks, the continuous-wave (CW) interaction of atoms with light yields power broadening and a significant sensitivity of the clock frequency to light-shift effects that contribute to the clock mid-term and long-term stability budget. Numerous approaches have been demonstrated in the literature to reduce light-shift effects in CW-CPT clocks [2-6]. In this study, using an external acousto-optic modulator to produce the interrogation sequence, we investigate the use of Ramsey-CPT spectroscopy in a buffer-gas filled microcell atomic clock. Some results are compared with those obtained in the standard CW regime. In the Ramsey-CPT case, the clock frequency dependence to laser power is reduced by a factor of 60 with a dark time T of 450 µs, at the expense of a 3 times higher operation power. The sensitivity to microwave power variations is reduced by a factor higher than 2. The Ramsey-CPT interrogation improves the clock Allan deviation for time scales in the 100-10 4 s range, at the expense of a degraded short-term stability when the dark time T is increased too much. A clock frequency stability of 3.8 × 10 −12 at 10 4 s is obtained with T = 450 µs, in comparison with the level of 8 × 10 −11 obtained in the standard CW case, in similar experimental conditions and the same cell. These results suggest that Ramsey-based interrogation protocols might be an attractive approach for the development of CSACs with enhanced mid-and long-term stability.
We investigate the use of pulsed Ramsey-CPT spectroscopy in a coherent population trapping (CPT) atomic clock using a microfabricated buffer gas-filled Cs vapor cell. Tests are performed on a table-top setup with an external acousto-optical modulator (AOM) to produce the optical CPT pulse sequence. A relevant reduction of the clock frequency sensitivity to laser power variations by a factor of about 40 is observed, in comparison with the standard continuous-wave (CW) regime, with a free-evolution time T = 450 μs. The dependence to microwave power variations is also reduced in the Ramsey-CPT interrogation case. With the same cell physics package and similar environmental conditions, the clock Allan deviation is clearly improved for time scales higher than 100 s in the Ramsey-CPT case. These results suggest that the use of Ramsey spectroscopy might be an attractive approach in miniature clocks