Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Journal of Applied Physics

Fast loading of a magneto-optical trap from a pulsed thermal source

József Fortágh, Alexander Grossmann, Theodor W. Hänsch, Claus Zimmermann

Published Dec 15, 1998• 74 citations
Publisher

Abstract

We report an efficient method to load atoms into a magneto-optical trap. A resistively heated alkali metal dispenser, which is mounted close to the trapping region, serves as a compact, pulsed source for Rb atoms. The atoms are captured by the magneto-optical trap within less than 3 s at a loading rate of more than 107 atoms per second. The lifetime of the trapped atoms exceeds the filling time by about 30 s.

DOI
10.1063/1.369018

Related papers

Fast and efficient loading of a Rb magneto-optical trap using light-induced atomic desorption

Sergey Nikitich Atutov, R. Calabrese, V. Guidi +10 more

We have obtained fast loading of a rubidium magneto-optical trap and very high collection efficiency by capturing the atoms desorbed by a light flash from a polydimethylsiloxane film deposited on the internal surface of a cell. The atoms are trapped with an effective loading time of about 65 ms at a loading rate greater than $2\ifmmode\times\else\texttimes\fi{}{10}^{8}$ atoms per second. This rate is larger than the values reported in literature and is obtained by preserving a long lifetime of the trapped atoms. This lifetime exceeds the filling time by nearly two orders of magnitude. Trap loading by light-induced desorption from siloxane compounds can be very effectively applied to store and trap a large number of atoms in the case of very weak atomic flux or extremely low vapor density. It can be also effectively used for fast production of ultracold atoms.

Physical Review A•May 22, 2003•95 citations

An atomic beam source for fast loading of a magneto-optical trap under high vacuum

Peter D. McDowall, Tzahi Grünzweig, Andrew J. Hilliard +1 more

We report on a directional atomic beam created using an alkali metal dispenser and a nozzle. By applying a high current (15 A) pulse to the dispenser at room temperature we can rapidly heat it to a temperature at which it starts dispensing, avoiding the need for preheating. The atomic beam produced is capable of loading 90% of a magneto-optical trap (MOT) in less than 7 s while maintaining a low vacuum pressure of <10(-11) Torr. The transverse velocity components of the atomic beam are measured to be within typical capture velocities of a rubidium MOT. Finally, we show that the atomic beam can be turned off within 1.8 s.

Review of Scientific Instruments•May 1, 2012•10 citations

Pulsed loading of a magneto-optical trap on an atom chip with fast recovery of ultrahigh vacuum

Vivek Singh, Vibhuti Bhushan Tiwari, A Chaudhary +2 more

Abstract Here, we present studies on pulsed loading of a rubidium (Rb) magneto-optical trap (MOT) in an ultra-high vacuum (UHV) environment on an atom chip. We have used a parallel combination of Rb dispensers for better heat dissipation to achieve fast UHV recovery in the chamber after the end of the current pulse to the dispensers. We have estimated the threshold heat energy required for activation of the dispensers for different values of current pulses. Although a pulse with a higher current value and shorter duration has a lower threshold heat energy, we operated the dispensers at moderate current pulse parameters (24 A, 10 s) for protection of the circuits. Nearly, 3 × 10 7 cold 87 Rb atoms were loaded in the MOT using this current pulse, with a UHV recovery time of ∼600 ms in the chamber. This fast recovery of UHV in the MOT chamber is useful for further experiments such as magnetic trapping and evaporative cooling of atoms in the same chamber.

arXiv:2403.11458•Laser Physics Letters•Dec 19, 2024•1 citation

Collimated, single-pass atom source from a pulsed alkali metal dispenser for laser-cooling experiments

Kevin L. Moore, Thomas Purdy, Kater W. Murch +3 more

We have developed an improved scheme for loading atoms into a magneto-optical trap (MOT) from a directed rubidium alkali metal dispenser in <10−10Torr ultrahigh vacuum conditions. A current-driven dispenser was surrounded with a cold absorbing “shroud” held at ⩽0°C, pumping rubidium atoms not directed into the MOT. This nearly eliminates background atoms and reduces the detrimental rise in pressure normally associated with these devices. The system can be well-described as a current-controlled, rapidly switched, two-temperature thermal beam, and was used to load a MOT with 3×108atoms.

arXiv:physics/0409011•Review of Scientific Instruments•Jan 7, 2005•23 citations

Loading and Compression of a Large Number of Rubidium Atoms Using a Semi-Dark Type Magneto-Optical Trap

Lan‐Sheng Yang, Bai-Tzeng Han, De-Sheng Hong +2 more

We have built an apparatus for setting up a double magneto-optical trap (double MOT) which allows more than 10 Rb atoms to be loaded in 15 seconds. This compact system consists mainly of a stainless steel chamber and a homemade glass cell. The two chambers are spatially separated by a small diameter transfer tube for differential pumping. The stainless steel chamber is maintained at a pressure of 10 Torr, enabling fast capturing of background Rb atoms. The optically cooled atomic clouds are pushed by a laser beam towards the glass cell which is in a much higher vacuum. Under this condition, the glass cell provides a rather long life time for holding the atoms. After the atoms are loaded in the temporarily bright MOT, a semi-dark type MOT compression is employed to reach a spatial density of 1×10 atoms/cm. The compressed atom clouds are further cooled by polarization gradient cooling to a temperature of 30 μK. The high phase space density cloud is suitable for experiments related to ultracold atoms.

Chinese Journal of Physics•Dec 1, 2007•3 citations

Loading of the narrow line Tm MOT from a pulsed cold atomic beam

M. O. Yaushev, D. Mishin, Dmitry O. Tregubov +2 more

We report on building a pulsed source of cold Tm atoms and loading of the narrow-line magneto-optical trap (MOT) from the cold atomic beam. We achieve the loading rate of the first-stage MOT in the primary chamber up to 108 atoms/s and obtain a cold atomic beam with the mean longitudinal velocity ∼10 m/s and an angular spread of 18 mrad in a pulsed mode. In this regime, we can form a cold atomic beam with up to 5 × 106 atoms at a 5 Hz repetition rate. We also introduce a novel method to enhance the capture velocity of the narrow-line MOT by incorporating an additional axial cooling beam and achieve loading efficiency η = 10% of the second-stage MOT in the science chamber. Our approach could be extended to other atomic species with similar properties, such as Sr, Yb, Dy, and Er, serving as a convenient alternative for the traditional 2D-MOT schemes. Providing rapid loading of the MOT in the science chamber, it would reduce preparation time of the atomic ensemble leading to a shorter dead time in spectroscopy experiments and a higher repetition rate.

arXiv:2411.08807•Review of Scientific Instruments•Mar 1, 2025•4 citations
We report an efficient method to load atoms into a magneto-optical trap. A resistively heated alkali metal dispenser, which is mounted close to the trapping region, serves as a compact, pulsed source for Rb atoms. The atoms are captured by the magneto-optical trap within less than 3 s at a loading rate of more than 107 atoms per second. The lifetime of the trapped atoms exceeds the filling time by about 30 s.
We have obtained fast loading of a rubidium magneto-optical trap and very high collection efficiency by capturing the atoms desorbed by a light flash from a polydimethylsiloxane film deposited on the internal surface of a cell. The atoms are trapped with an effective loading time of about 65 ms at a loading rate greater than $2\ifmmode\times\else\texttimes\fi{}{10}^{8}$ atoms per second. This rate is larger than the values reported in literature and is obtained by preserving a long lifetime of the trapped atoms. This lifetime exceeds the filling time by nearly two orders of magnitude. Trap loading by light-induced desorption from siloxane compounds can be very effectively applied to store and trap a large number of atoms in the case of very weak atomic flux or extremely low vapor density. It can be also effectively used for fast production of ultracold atoms.
We report on a directional atomic beam created using an alkali metal dispenser and a nozzle. By applying a high current (15 A) pulse to the dispenser at room temperature we can rapidly heat it to a temperature at which it starts dispensing, avoiding the need for preheating. The atomic beam produced is capable of loading 90% of a magneto-optical trap (MOT) in less than 7 s while maintaining a low vacuum pressure of <10(-11) Torr. The transverse velocity components of the atomic beam are measured to be within typical capture velocities of a rubidium MOT. Finally, we show that the atomic beam can be turned off within 1.8 s.
Abstract Here, we present studies on pulsed loading of a rubidium (Rb) magneto-optical trap (MOT) in an ultra-high vacuum (UHV) environment on an atom chip. We have used a parallel combination of Rb dispensers for better heat dissipation to achieve fast UHV recovery in the chamber after the end of the current pulse to the dispensers. We have estimated the threshold heat energy required for activation of the dispensers for different values of current pulses. Although a pulse with a higher current value and shorter duration has a lower threshold heat energy, we operated the dispensers at moderate current pulse parameters (24 A, 10 s) for protection of the circuits. Nearly, 3 × 10 7 cold 87 Rb atoms were loaded in the MOT using this current pulse, with a UHV recovery time of ∼600 ms in the chamber. This fast recovery of UHV in the MOT chamber is useful for further experiments such as magnetic trapping and evaporative cooling of atoms in the same chamber.
We have developed an improved scheme for loading atoms into a magneto-optical trap (MOT) from a directed rubidium alkali metal dispenser in <10−10Torr ultrahigh vacuum conditions. A current-driven dispenser was surrounded with a cold absorbing “shroud” held at ⩽0°C, pumping rubidium atoms not directed into the MOT. This nearly eliminates background atoms and reduces the detrimental rise in pressure normally associated with these devices. The system can be well-described as a current-controlled, rapidly switched, two-temperature thermal beam, and was used to load a MOT with 3×108atoms.
We have built an apparatus for setting up a double magneto-optical trap (double MOT) which allows more than 10 Rb atoms to be loaded in 15 seconds. This compact system consists mainly of a stainless steel chamber and a homemade glass cell. The two chambers are spatially separated by a small diameter transfer tube for differential pumping. The stainless steel chamber is maintained at a pressure of 10 Torr, enabling fast capturing of background Rb atoms. The optically cooled atomic clouds are pushed by a laser beam towards the glass cell which is in a much higher vacuum. Under this condition, the glass cell provides a rather long life time for holding the atoms. After the atoms are loaded in the temporarily bright MOT, a semi-dark type MOT compression is employed to reach a spatial density of 1×10 atoms/cm. The compressed atom clouds are further cooled by polarization gradient cooling to a temperature of 30 μK. The high phase space density cloud is suitable for experiments related to ultracold atoms.
We report on building a pulsed source of cold Tm atoms and loading of the narrow-line magneto-optical trap (MOT) from the cold atomic beam. We achieve the loading rate of the first-stage MOT in the primary chamber up to 108 atoms/s and obtain a cold atomic beam with the mean longitudinal velocity ∼10 m/s and an angular spread of 18 mrad in a pulsed mode. In this regime, we can form a cold atomic beam with up to 5 × 106 atoms at a 5 Hz repetition rate. We also introduce a novel method to enhance the capture velocity of the narrow-line MOT by incorporating an additional axial cooling beam and achieve loading efficiency η = 10% of the second-stage MOT in the science chamber. Our approach could be extended to other atomic species with similar properties, such as Sr, Yb, Dy, and Er, serving as a convenient alternative for the traditional 2D-MOT schemes. Providing rapid loading of the MOT in the science chamber, it would reduce preparation time of the atomic ensemble leading to a shorter dead time in spectroscopy experiments and a higher repetition rate.