Physica B Condensed Matter

Multichannel DC SQUID system with two stage configuration

H. Furukawa, S. Fujita, Ayumu Matani, M. Yoshida, K. Shirae

Published Aug 1, 1990• 1 citation
Publisher
DOI
10.1016/s0921-4526(90)80899-t

Related papers

Two Stage dc SQUID-based Amplifier with Double transformer Coupling Scheme

Dmitri E. Kirichenko, A.B. Pavolotskij, I.G. Prokhorova +4 more

•Jan 1, 1997•2 citations

Stabilization and optimization of a two-stage dc SQUID coupled to a high Q resonator

Andrea Vinante, M. Bonaldi, P. Falferi +4 more

Physica C Superconductivity•Mar 1, 2002•22 citations

New amplifier configuration based on the circulating current state of a DC SQUID

Andrew D. Hibbs, Michael A. Krupka, Linas R. Kunstmanas +4 more

Physica C Superconductivity•Mar 1, 2002•4 citations

Multi-Channel High T c SQUID

Hideo Itozaki, Saburo Tanaka, Tatsuoki Nagaishi +1 more

IEICE Transactions on Electronics•Aug 25, 1994•6 citations

Multichannel DC SQUID System

Hisao Furukawa, K. Shirae

A new essential multichannel dc SQUID system has been devised. The system consists of two stages of dc SQUIDs; in the first stage, a number of dc SQUIDs equivalent to the input number detect the input signals, and the sum of the first-stage output modulates the carrier of the second-stage dc SQUID and is sent by the carrier to a room temperature amplifier, where the mixed input signals are separated into the original signals. To verify the system operation, a three channel dc SQUID system has been developed and good results have been obtained.

Japanese Journal of Applied Physics•Mar 1, 1989•8 citations

Sensitivity enhancement of Quantum Design dc superconducting quantum interference devices in two-stage configuration

R. Mezzena, Andrea Vinante, P. Falferi +5 more

The energy sensitivity of a direct current (dc) superconducting quantum interference device (SQUID) can be improved if it is operated in a two-stage configuration. Employing this technique, a commercial dc SQUID system was modified and made competitive with other sensors especially designed for very low noise applications. We report the noise measurements performed in the temperature range 4.2 K–25 mK. At 4.2 K, the coupled energy sensitivity obtained with the two-stage dc SQUID was approximately ten times better than with a conventional readout electronics. The noise energy decreases linearly until approximately 300 mK, in good agreement with theoretical previsions. At lower temperature the hot-electron effect produces a saturation and the best energy sensitivity measured with open input coil is 35 ℏ.

Review of Scientific Instruments•Sep 1, 2001•31 citations
A new essential multichannel dc SQUID system has been devised. The system consists of two stages of dc SQUIDs; in the first stage, a number of dc SQUIDs equivalent to the input number detect the input signals, and the sum of the first-stage output modulates the carrier of the second-stage dc SQUID and is sent by the carrier to a room temperature amplifier, where the mixed input signals are separated into the original signals. To verify the system operation, a three channel dc SQUID system has been developed and good results have been obtained.
The energy sensitivity of a direct current (dc) superconducting quantum interference device (SQUID) can be improved if it is operated in a two-stage configuration. Employing this technique, a commercial dc SQUID system was modified and made competitive with other sensors especially designed for very low noise applications. We report the noise measurements performed in the temperature range 4.2 K–25 mK. At 4.2 K, the coupled energy sensitivity obtained with the two-stage dc SQUID was approximately ten times better than with a conventional readout electronics. The noise energy decreases linearly until approximately 300 mK, in good agreement with theoretical previsions. At lower temperature the hot-electron effect produces a saturation and the best energy sensitivity measured with open input coil is 35 ℏ.