To date, the optical field in OCT has been treated almost exclusively classically. This work examines the OCT interferometer in full quantization, identifying often ignored effects as vacuum fluctuations, indistinguishable paths, radiation pressure, and photon statistics.
The traditional concept of the optical complex transmittance (OCT) does not provide an experimental opportunity to speak for itself, due to the fact that no measuring instrument catches up with the fluctuation of light fields. By coherent theory, we give it a measurable counterpart, and thus justify the concept. To our knowledge, it is the first time to valuate an object in optics in the terms of observable quantities. Meanwhile the applicability to obtain the full knowledge of an OCT is suggested.
Optical coherence tomography has become an important imaging technology in cardiology and ophthalmology, with other applications under investigations. Major advances in optical coherence tomography (OCT) imaging are likely to occur through a quantum field approach to the technology. In this paper, which is the first part in a series on the topic, the quantum basis of OCT first order correlations is expressed in terms of full field quantization. Specifically first order correlations are treated as the linear sum of single photon interferences along indistinguishable paths. Photons and the electromagnetic (EM) field are described in terms of quantum harmonic oscillators. While the author feels the study of quantum second order correlations will lead to greater paradigm shifts in the field, addressed in part II, advances from the study of quantum first order correlations are given. In particular, ranging errors are discussed (with remedies) from vacuum fluctuations through the detector port, photon counting errors, and position probability amplitude uncertainty. In addition, the principles of quantum field theory and first order correlations are needed for studying second order correlations in part II.
The performance of an interferometric gravity-wave detector is analyzed, treating both the motion of the mirrors and the optical fields quantum mechanically, in continuous time. Kerr cells in each arm of the interferometer are used to counter the effects of radiation-pressure fluctuations, a feedback loop is used to keep the interferometer operating at the proper null, and a large mean-field assumption is used to linearize the analysis. When narrow-band disturbances are being measured, the performance of this interferometer can greatly surpass the standard quantum limit. When the Kerr cells are removed, the interferometer operates at the standard quantum limit, and this analysis agrees with earlier studies.