Physical Review A

Reduction of radiation-pressure-induced fluctuations in interferometric gravity-wave detectors

Roy S. Bondurant

Published Nov 1, 1986• 42 citations
Publisher

Abstract

The performance of an interferometric gravity-wave detector is analyzed, treating both the motion of the mirrors and the optical fields quantum mechanically, in continuous time. Kerr cells in each arm of the interferometer are used to counter the effects of radiation-pressure fluctuations, a feedback loop is used to keep the interferometer operating at the proper null, and a large mean-field assumption is used to linearize the analysis. When narrow-band disturbances are being measured, the performance of this interferometer can greatly surpass the standard quantum limit. When the Kerr cells are removed, the interferometer operates at the standard quantum limit, and this analysis agrees with earlier studies.

DOI
10.1103/physreva.34.3927

Related papers

Quantum limits in interferometric detection of gravitational radiation

A. F. Pace, Matthew J. Collett, Daniel F. Walls

A spectral analysis is given of the quantum fluctuations in an optical interferometer to detect gravitational radiation. Two different methods of beating the standard quantum limit are examined: directing a squeezed state into the nonlaser input port of the interferometer and placing a Kerr medium into both arms of the interferometer. For both the Kerr medium and large squeezing cases the interferometer system is limited ultimately by the damping noise in the mirrors, not by noise in the light.

Physical Review A•Apr 1, 1993•169 citations

Quantum Limit on the Michelson Interferometer used for Gravitational-Wave Detection

R. Loudon

The quantum limitations on measurements of the relative positions of the two mirrors in a Michelson gravity-wave detector are derived. The effects of intensity fluctuations in the two light beams and radiation pressure on the mirrors are modeled in a unified calculation. The radiation-pressure uncertainty in mirror position differs in general from earlier work, but gives agreement for coherent input light.

Physical Review Letters•Sep 21, 1981•114 citations

Beating quantum limits in interferometers with quantum locking of mirrors

A. Heidmann, Jean-Michel Courty, M. Pinard +1 more

The sensitivity in interferometric measurements such as gravitational-wave detectors is ultimately limited by quantum noise of light. We discuss the use of feedback mechanisms to reduce the quantum effects of radiation pressure. Recent experiments have shown that it is possible to reduce the thermal motion of a mirror by cold damping. The mirror motion is measured with an optomechanical sensor based on a high-finesse cavity, and reduced by a feedback loop. We show that this technique can be extended to lock the mirror at the quantum level. In gravitational-waves interferometers with Fabry-Perot cavities in each arms, it is even possible to use a single feedback mechanism to lock one cavity mirror on the other. This quantum locking greatly improves the sensitivity of the interferometric measurement. It is furthermore insensitive to imperfections such as losses in the interferometer.

arXiv:quant-ph/0311167•Journal of Optics B Quantum and Semiclassical Optics•Jul 28, 2004•12 citations

Quantum Measurement in Gravitational-Wave Detectors

Yanbei Chen

Laser interferometric gravitational-wave detectors measure tiny motions of macroscopic mirrors. Complex interferometer configurations and quantum optical techniques will be used to enhance sensitivity in future interferometers, which will reach and surpass the Standard Quantum Limit.

Frontiers in Optics•Jan 1, 2007•0 citations

Quantum Measurements in Gravitational-Wave Detectors

Yanbei Chen

Laser interferometric gravitational-wave detectors measure tiny motions of macroscopic test masses. Complex interferometer configurations and quantum optical techniques will be used to enhance sensitivity in future interferometers, which will reach and surpass the Standard Quantum Limit.

Frontiers in Optics•Jan 1, 2006•0 citations

Noise in gravitational-wave detectors and other classical-force measurements is not influenced by test-mass quantization

Vladimir B. Braginsky, M. L. Gorodetsky, Farid Ya Khalili +3 more

It is shown that photon shot noise and radiation-pressure back-action noise are the sole forms of quantum noise in interferometric gravitational wave detectors that operate near or below the standard quantum limit, if one filters the interferometer output appropriately. No additional noise arises from the test masses' initial quantum state or from reduction of the test-mass state due to measurement of the interferometer output or from the uncertainty principle associated with the test-mass state. Two features of interferometers are central to these conclusions: (i) The interferometer output [the photon number flux $\mathcal{N}^(t)$ entering the final photodetector] commutes with itself at different times in the Heisenberg picture, $[\mathcal{N}^(t),\mathcal{N}^{(t}^{\ensuremath{'}})]=0$ and thus can be regarded as classical. (ii) This number flux is linear to high accuracy in the test-mass initial position and momentum operators ${x}_{o}$ and ${p}_{o},$ and those operators influence the measured photon flux $\mathcal{N}^(t)$ in manners that can easily be removed by filtering. For example, in most interferometers ${x}_{o}$ and ${p}_{o}$ appear in $\mathcal{N}^(t)$ only at the test masses' $\ensuremath{\sim}1\mathrm{Hz}$ pendular swinging frequency and their influence is removed when the output data are high-pass filtered to get rid of noise below $\ensuremath{\sim}10\mathrm{Hz}.$ The test-mass operators ${x}_{o}$ and ${p}_{o}$ contained in the unfiltered output $\mathcal{N}^(t)$ make a nonzero contribution to the commutator $[\mathcal{N}^(t),\mathcal{N}^{(t}^{\ensuremath{'}})].$ That contribution is precisely canceled by a nonzero commutation of the photon shot noise and radiation-pressure noise, which also are contained in $\mathcal{N}^(t).$ This cancellation of commutators is responsible for the fact that it is possible to derive an interferometer's standard quantum limit from test-mass considerations, and independently from photon-noise considerations, and get identically the same result. These conclusions are all true for a far wider class of measurements than just gravitational-wave interferometers. To elucidate them, this paper presents a series of idealized thought experiments that are free from the complexities of real measuring systems.

arXiv:gr-qc/0109003•Physical review. D. Particles, fields, gravitation, and cosmology/Physical review. D. Particles and fields•Apr 7, 2003•84 citations
The performance of an interferometric gravity-wave detector is analyzed, treating both the motion of the mirrors and the optical fields quantum mechanically, in continuous time. Kerr cells in each arm of the interferometer are used to counter the effects of radiation-pressure fluctuations, a feedback loop is used to keep the interferometer operating at the proper null, and a large mean-field assumption is used to linearize the analysis. When narrow-band disturbances are being measured, the performance of this interferometer can greatly surpass the standard quantum limit. When the Kerr cells are removed, the interferometer operates at the standard quantum limit, and this analysis agrees with earlier studies.
The sensitivity in interferometric measurements such as gravitational-wave detectors is ultimately limited by quantum noise of light. We discuss the use of feedback mechanisms to reduce the quantum effects of radiation pressure. Recent experiments have shown that it is possible to reduce the thermal motion of a mirror by cold damping. The mirror motion is measured with an optomechanical sensor based on a high-finesse cavity, and reduced by a feedback loop. We show that this technique can be extended to lock the mirror at the quantum level. In gravitational-waves interferometers with Fabry-Perot cavities in each arms, it is even possible to use a single feedback mechanism to lock one cavity mirror on the other. This quantum locking greatly improves the sensitivity of the interferometric measurement. It is furthermore insensitive to imperfections such as losses in the interferometer.
It is shown that photon shot noise and radiation-pressure back-action noise are the sole forms of quantum noise in interferometric gravitational wave detectors that operate near or below the standard quantum limit, if one filters the interferometer output appropriately. No additional noise arises from the test masses' initial quantum state or from reduction of the test-mass state due to measurement of the interferometer output or from the uncertainty principle associated with the test-mass state. Two features of interferometers are central to these conclusions: (i) The interferometer output [the photon number flux N(t)\mathcal{N}^(t)N(t) entering the final photodetector] commutes with itself at different times in the Heisenberg picture, $[\mathcal{N}^(t),\mathcal{N}^{(t}^{\ensuremath{'}})]=0$ and thus can be regarded as classical. (ii) This number flux is linear to high accuracy in the test-mass initial position and momentum operators xo{x}_{o}xo​ and po,{p}_{o},po​, and those operators influence the measured photon flux N(t)\mathcal{N}^(t)N(t) in manners that can easily be removed by filtering. For example, in most interferometers xo{x}_{o}xo​ and po{p}_{o}po​ appear in N(t)\mathcal{N}^(t)N(t) only at the test masses' $\ensuremath{\sim}1\mathrm{Hz}$ pendular swinging frequency and their influence is removed when the output data are high-pass filtered to get rid of noise below $\ensuremath{\sim}10\mathrm{Hz}.$ The test-mass operators xo{x}_{o}xo​ and po{p}_{o}po​ contained in the unfiltered output N(t)\mathcal{N}^(t)N(t) make a nonzero contribution to the commutator $[\mathcal{N}^(t),\mathcal{N}^{(t}^{\ensuremath{'}})].$ That contribution is precisely canceled by a nonzero commutation of the photon shot noise and radiation-pressure noise, which also are contained in N(t).\mathcal{N}^(t).N(t). This cancellation of commutators is responsible for the fact that it is possible to derive an interferometer's standard quantum limit from test-mass considerations, and independently from photon-noise considerations, and get identically the same result. These conclusions are all true for a far wider class of measurements than just gravitational-wave interferometers. To elucidate them, this paper presents a series of idealized thought experiments that are free from the complexities of real measuring systems.