The performance of an interferometric gravity-wave detector is analyzed, treating both the motion of the mirrors and the optical fields quantum mechanically, in continuous time. Kerr cells in each arm of the interferometer are used to counter the effects of radiation-pressure fluctuations, a feedback loop is used to keep the interferometer operating at the proper null, and a large mean-field assumption is used to linearize the analysis. When narrow-band disturbances are being measured, the performance of this interferometer can greatly surpass the standard quantum limit. When the Kerr cells are removed, the interferometer operates at the standard quantum limit, and this analysis agrees with earlier studies.
The sensitivity in interferometric measurements such as gravitational-wave detectors is ultimately limited by quantum noise of light. We discuss the use of feedback mechanisms to reduce the quantum effects of radiation pressure. Recent experiments have shown that it is possible to reduce the thermal motion of a mirror by cold damping. The mirror motion is measured with an optomechanical sensor based on a high-finesse cavity, and reduced by a feedback loop. We show that this technique can be extended to lock the mirror at the quantum level. In gravitational-waves interferometers with Fabry-Perot cavities in each arms, it is even possible to use a single feedback mechanism to lock one cavity mirror on the other. This quantum locking greatly improves the sensitivity of the interferometric measurement. It is furthermore insensitive to imperfections such as losses in the interferometer.
It is shown that photon shot noise and radiation-pressure back-action noise are the sole forms of quantum noise in interferometric gravitational wave detectors that operate near or below the standard quantum limit, if one filters the interferometer output appropriately. No additional noise arises from the test masses' initial quantum state or from reduction of the test-mass state due to measurement of the interferometer output or from the uncertainty principle associated with the test-mass state. Two features of interferometers are central to these conclusions: (i) The interferometer output [the photon number flux
N(t) entering the final photodetector] commutes with itself at different times in the Heisenberg picture, $[\mathcal{N}^(t),\mathcal{N}^{(t}^{\ensuremath{'}})]=0$ and thus can be regarded as classical. (ii) This number flux is linear to high accuracy in the test-mass initial position and momentum operators
xo and
po, and those operators influence the measured photon flux
N(t) in manners that can easily be removed by filtering. For example, in most interferometers
xo and
po appear in
N(t) only at the test masses' $\ensuremath{\sim}1\mathrm{Hz}$ pendular swinging frequency and their influence is removed when the output data are high-pass filtered to get rid of noise below $\ensuremath{\sim}10\mathrm{Hz}.$ The test-mass operators
xo and
po contained in the unfiltered output
N(t) make a nonzero contribution to the commutator $[\mathcal{N}^(t),\mathcal{N}^{(t}^{\ensuremath{'}})].$ That contribution is precisely canceled by a nonzero commutation of the photon shot noise and radiation-pressure noise, which also are contained in
N(t). This cancellation of commutators is responsible for the fact that it is possible to derive an interferometer's standard quantum limit from test-mass considerations, and independently from photon-noise considerations, and get identically the same result. These conclusions are all true for a far wider class of measurements than just gravitational-wave interferometers. To elucidate them, this paper presents a series of idealized thought experiments that are free from the complexities of real measuring systems.