Review of Josephson effect detection mechanisms

Sidney Shapiro

Published Jan 1, 1974• 1 citation
Publisher

Abstract

Some modes of video, heterodyne, and oscillator-mixer operation of Josephson junctions were reviewed.
DOI
10.1051/rphysap:01974009010500

Related papers

The use of a Josephson junction as a heterodyne-mixer at millimeter wavelengths

A. I. Akimenko, I. K. Ianson, В. С. Соловьев

•May 1, 1975•0 citations

Experiments on the Josephson junction amplifier. Final report (Part 3)

Aldert van der Ziel, Hyeokmin Choe

•Mar 1, 1972•0 citations

Superconducting devices for millimeter and submillimeter wavelengths

P. L. Richards

Josephson junctions are highly nonlinear and respond up to infrared frequencies. A wide variety of high frequency applications have been explored. In addition, several high frequency superconducting devices are being developed which do not use the Josephson effect. These include a superconducting version of the Schottky barrier diode for use as a heterodyne mixer and a video detector, and also a composite superconducting bolometer. In this review, the state of development of superconducting mixers, detectors, and parametric amplifiers at microwave, millimeter, and submillimeter wavelengths is discussed. Emphasis will be placed on developments which have taken place since 1974 when a previous review was circulated.

De Gruyter eBooks•Dec 31, 1977•7 citations

ミリ波・サブミリ波検出器

Kazuo Fujisawa

In this report, Josephson junction detectors for millimeter and submillimeter waves are surveyed. Emphasis is placed on heterodyne detectors (mixers). Others are briefly referred to, such as video detectors, bolometers, quasiparticle mixers and parametric amplifiers. Also, three kinds of Josephson junctions for detector use are mentioned and brief comments are given on them. These are tunnel junctions, thin film microbridges and point contacts.Thermally cyclable oxide barrier tunnel junctions have been obtained and used as low noise quasiparticle mixers at 115GHz. They have lower noise temperatures compared to Josephson effect mixers, but the receiver noise temperatures are not lowered owing to their lower conversion efficiencies. Thin film microbridges suffer from low junction resistances and also from heating effects caused by d.c. bias supply and r.f. incident power. There seems to exist many problems to be overcome in order to make good submillimeter wave detectors by tunnel junctions or microbridges.Point contacts are now widely used as sensitive detectors for millimeter and submillimeter waves. Although there exist difficulties for making rugged and thermally cyclable point contacts, the techniques for making them have made considerable progress, and a new construction of detector mount has appeared, which brought a low noise mixer at 115GHz thermally cyclable.It is shown that the sensitivity of video detectors decreases as proportional to the inverse square of frequency. So, for submillimeter waves, video detectors are inferior to superconducting bolometers.Recent progress in heterodyne detectors (fundamental and harmonic mixers) are touched on. They are superior to Shottky diode mixers in that they have much smaller NEP's and much higher conversion efficiencies (especially in harmonic mixers), and also in that they operate with much smaller LO power. Experimental curves of IF output power v.s. bias voltage are given for harmonic mixers with harmonic number N=7 and N=10. It is noted that harmonic mixers with even harmonic number are preferable, because they can operate at zero bias voltage. Among them, low even numbers 2 or 4 are recommended in regards to good conversion efficiency.By using Josephson junctions, a peculiar parametric operation is possible, namely doubly degenerate mode. This mode operates under zero d.c. bias by choosing pump frequency as 2ωp=ωs+ωi, ωp-ωs-ωi. Zero bias operation allows the adoption of microbridge arrays. A parametric amplifier with 160 microbridge arrays was built at 33GHz, and showed amplifier gain of 15dB and noise temperature of 20K.

TEION KOGAKU (Journal of Cryogenics and Superconductivity Society of Japan)•Jan 1, 1980•0 citations

Studies of noise in Josephson-effect mixers and their potential for submillimeter heterodyne detection

Robert J. Schoelkopf

NOTE: Text or symbols not renderable in plain ASCII are indicated by [...]. Abstract is included in .pdf document. This thesis describes both theoretical and experimental investigations into the dynamics and noise processes of Josephson junctions, with the intent of evaluating their potential as mixers in heterodyne instruments for submillimeter-wave (i.e., the frequency range from 300 GHz to 3THz) detection. Superconducting tunnel junctions utilizing the nonlinearity due to photon-assisted tunneling of quasiparticles (SIS mixers) have become the state-of-the-art technology for sensitive heterodyne detection up to frequencies of about 700 [...]. Recent progress in the fabrication of high [...], superconductors has led to Josephson-effect devices with [...] products of up to ten millivolts, which might be suitable for mixing at frequencies of many terahertz. The key question for weighing the prospects for high-frequency Josephson mixers is that of the sensitivity which can be attained. Previous experimental work on Josephson mixing suggests the existence of an "excess" noise, which degrades the sensitivity. Theoretical modeling of mixer performance, based on the resistivelyshunted junction (RSJ) model for the dynamics of the device, also indicates the presence of larger noise than expected. The origin of this noise was not clearly understood, however, nor was its exact magnitude or expected scaling with frequency or junction characteristics known. In addition, previous experiments utilized crude devices of the point-contact type, which were unstable and thus undesirable for real applications. In the first part of this thesis research, extensive numerical simulations were performed with the RSJ model, including calculations of mixer noise and conversion efficiency. These calculations have revealed that the source of excess noise is the AC Josephson oscillations of the device, which can be completely incoherent, with a linewidth comparable to their frequency. Thus they appear as a broadband noise source. While this noise is intrinsic and unavoidable, an optimized mixer is still shown to be capable of interesting sensitivity levels, and the excess noise is expected to become relatively less important as the operating frequency is increased. Secondly, a process has been developed for the fabrication of stable, well-characterized, and reproducible Josephson devices based on resistively-shunted Nb and NbN tunnel junctions. The devices utilize submicron-area, high current-density tunnel junctions and a AuGe shunt resistor to yield completely non-hysteretic I-V curves, normal-state resistances of about [...] products of about half a millivolt. These devices should be nearly optimal for mixing at [...]. Heterodyne measurements using these junctions have been performed in a waveguide mixer mount. Receiver temperatures as low as 190 K (DSB), with -6 dB conversion efficiency, have been obtained at 100 [...], but these results are still a factor of about four higher than those predicted by the RSJ simulations. Accurate measurements of the available noise power of the junctions at the intermediate frequency of 1.5 [...] were made, and confirmed that the receivers were limited by elevated junction output noise. The deviations of the noise from theoretical predictions are shown to be caused by the nonlinear interaction of the junction with the embedding circuit. While this work points out some of the complexity introduced by the strong nonlinearity of Josephson devices, it is still expected that Josephson-effect mixers may be useful for heterodyne detection at very high frequencies.

•Nov 7, 2007•5 citations

Heterodyne Mixing and Direct Detection with High Temperature Josephson Junctions

Erich N. Grossman, Leila R. Vale

•May 1, 1994•3 citations
Josephson junctions are highly nonlinear and respond up to infrared frequencies. A wide variety of high frequency applications have been explored. In addition, several high frequency superconducting devices are being developed which do not use the Josephson effect. These include a superconducting version of the Schottky barrier diode for use as a heterodyne mixer and a video detector, and also a composite superconducting bolometer. In this review, the state of development of superconducting mixers, detectors, and parametric amplifiers at microwave, millimeter, and submillimeter wavelengths is discussed. Emphasis will be placed on developments which have taken place since 1974 when a previous review was circulated.
In this report, Josephson junction detectors for millimeter and submillimeter waves are surveyed. Emphasis is placed on heterodyne detectors (mixers). Others are briefly referred to, such as video detectors, bolometers, quasiparticle mixers and parametric amplifiers. Also, three kinds of Josephson junctions for detector use are mentioned and brief comments are given on them. These are tunnel junctions, thin film microbridges and point contacts.Thermally cyclable oxide barrier tunnel junctions have been obtained and used as low noise quasiparticle mixers at 115GHz. They have lower noise temperatures compared to Josephson effect mixers, but the receiver noise temperatures are not lowered owing to their lower conversion efficiencies. Thin film microbridges suffer from low junction resistances and also from heating effects caused by d.c. bias supply and r.f. incident power. There seems to exist many problems to be overcome in order to make good submillimeter wave detectors by tunnel junctions or microbridges.Point contacts are now widely used as sensitive detectors for millimeter and submillimeter waves. Although there exist difficulties for making rugged and thermally cyclable point contacts, the techniques for making them have made considerable progress, and a new construction of detector mount has appeared, which brought a low noise mixer at 115GHz thermally cyclable.It is shown that the sensitivity of video detectors decreases as proportional to the inverse square of frequency. So, for submillimeter waves, video detectors are inferior to superconducting bolometers.Recent progress in heterodyne detectors (fundamental and harmonic mixers) are touched on. They are superior to Shottky diode mixers in that they have much smaller NEP's and much higher conversion efficiencies (especially in harmonic mixers), and also in that they operate with much smaller LO power. Experimental curves of IF output power v.s. bias voltage are given for harmonic mixers with harmonic number N=7 and N=10. It is noted that harmonic mixers with even harmonic number are preferable, because they can operate at zero bias voltage. Among them, low even numbers 2 or 4 are recommended in regards to good conversion efficiency.By using Josephson junctions, a peculiar parametric operation is possible, namely doubly degenerate mode. This mode operates under zero d.c. bias by choosing pump frequency as 2ωp=ωs+ωi, ωp-ωs-ωi. Zero bias operation allows the adoption of microbridge arrays. A parametric amplifier with 160 microbridge arrays was built at 33GHz, and showed amplifier gain of 15dB and noise temperature of 20K.
NOTE: Text or symbols not renderable in plain ASCII are indicated by [...]. Abstract is included in .pdf document. This thesis describes both theoretical and experimental investigations into the dynamics and noise processes of Josephson junctions, with the intent of evaluating their potential as mixers in heterodyne instruments for submillimeter-wave (i.e., the frequency range from 300 GHz to 3THz) detection. Superconducting tunnel junctions utilizing the nonlinearity due to photon-assisted tunneling of quasiparticles (SIS mixers) have become the state-of-the-art technology for sensitive heterodyne detection up to frequencies of about 700 [...]. Recent progress in the fabrication of high [...], superconductors has led to Josephson-effect devices with [...] products of up to ten millivolts, which might be suitable for mixing at frequencies of many terahertz. The key question for weighing the prospects for high-frequency Josephson mixers is that of the sensitivity which can be attained. Previous experimental work on Josephson mixing suggests the existence of an "excess" noise, which degrades the sensitivity. Theoretical modeling of mixer performance, based on the resistivelyshunted junction (RSJ) model for the dynamics of the device, also indicates the presence of larger noise than expected. The origin of this noise was not clearly understood, however, nor was its exact magnitude or expected scaling with frequency or junction characteristics known. In addition, previous experiments utilized crude devices of the point-contact type, which were unstable and thus undesirable for real applications. In the first part of this thesis research, extensive numerical simulations were performed with the RSJ model, including calculations of mixer noise and conversion efficiency. These calculations have revealed that the source of excess noise is the AC Josephson oscillations of the device, which can be completely incoherent, with a linewidth comparable to their frequency. Thus they appear as a broadband noise source. While this noise is intrinsic and unavoidable, an optimized mixer is still shown to be capable of interesting sensitivity levels, and the excess noise is expected to become relatively less important as the operating frequency is increased. Secondly, a process has been developed for the fabrication of stable, well-characterized, and reproducible Josephson devices based on resistively-shunted Nb and NbN tunnel junctions. The devices utilize submicron-area, high current-density tunnel junctions and a AuGe shunt resistor to yield completely non-hysteretic I-V curves, normal-state resistances of about [...] products of about half a millivolt. These devices should be nearly optimal for mixing at [...]. Heterodyne measurements using these junctions have been performed in a waveguide mixer mount. Receiver temperatures as low as 190 K (DSB), with -6 dB conversion efficiency, have been obtained at 100 [...], but these results are still a factor of about four higher than those predicted by the RSJ simulations. Accurate measurements of the available noise power of the junctions at the intermediate frequency of 1.5 [...] were made, and confirmed that the receivers were limited by elevated junction output noise. The deviations of the noise from theoretical predictions are shown to be caused by the nonlinear interaction of the junction with the embedding circuit. While this work points out some of the complexity introduced by the strong nonlinearity of Josephson devices, it is still expected that Josephson-effect mixers may be useful for heterodyne detection at very high frequencies.