Journal of Physics Conference Series

Noise cancellation properties of displacement noise free interferometer

Shuichi Sato, Seiji Kawamura, A. Nishizawa, Yanbei Chen

Published May 1, 2010• 0 citations
Publisher

Abstract

We have demonstrated the practical feasibility of a displacement- and frequency-noise-free laser interferometer (DFI) by partially implementing a recently proposed optical configuration using bi-directional Mach-Zehnder interferometers (MZIs). The noise cancellation efficiency was evaluated by comparing the displacement noise spectrum of the MZIs and the DFI, demonstrating up to 50 dB of noise cancellation. In addition, the possible extension of DFI as QND device is explored.

DOI
10.1088/1742-6596/228/1/012026

Related papers

変位雑音フリー干渉計を用いた量子非破壊測定

光純 白澤, Koya SHIRASAWA

Displacement-noise-free interferometer (DFI) has developed for gravitational-wave (GW) detection free from any kind of displacement noise, which limits sensitivity of conventional laser interferometer GW detectors. The DFI mechanism can be also applied to quantum radiation pressure noise (RPN) in principle, and thus DFI allows ultrasensitive sensing beyond the so-called standard quantum limit. Namely, DFI can be a quantum-non-demolition (QND) measurement device for GW detection. The goal of this study is to examine the QND characteristics by cancelling RPN after observing it. Since not only obtaining the two signals which have same displacement information on the mirrors for the DFI system but amplifying the incident laser power to observe RPN are required for the experiment, I contrived a new optical design, a bidirectional triangular ring cavity DFI (RC-DFI). In this thesis, I introduced superiority of the optical system as compared to Mach-Zehnder type, and furthermore I demonstrated length control experiment of the cavity for verifying whether the noise cancellation ability on the above optical system will be still confirmed. Key Words: Gravitational-wave, Displacement-noise-free interferometry, Quantum-non-demolition measurement

•Mar 31, 2017•0 citations

Quantum Precision Limits of Displacement Noise-Free Interferometers

Tuvia Gefen, Rajashik Tarafder, R. X. Adhikari +1 more

Current laser-interferometric gravitational wave detectors suffer from a fundamental limit to their precision due to the displacement noise of optical elements contributed by various sources. Several schemes for displacement noise-free interferometers (DFI) have been proposed to mitigate their effects. The idea behind these schemes is similar to decoherence-free subspaces in quantum sensing; i.e., certain modes contain information about the gravitational waves but are insensitive to the mirror motion (displacement noise). We derive quantum precision limits for general DFI schemes, including optimal measurement basis and optimal squeezing schemes. We introduce a triangular cavity DFI scheme and apply our general bounds to it. Precision analysis of this scheme with different noise models shows that the DFI property leads to interesting sensitivity profiles and improved precision due to noise mitigation and larger gain from squeezing.

arXiv:2209.02998•Physical Review Letters•Jan 8, 2024•12 citations

Noise-suppressing and lock-free optical interferometer for cold atom experiments

Xiao-Xiao Ma, Xian Zhang, Kaikai Huang +1 more

A novel noise-suppressing and lock-free interferometer is proposed and experimentally demonstrated in the study of the quantum non-destructive (QND) interaction of cold atoms. A QND measurement based on far-off resonant dispersive probing is usually carried out by a Mach-Zehnder type interferometer. It is an experimental challenge in its own right to reduce the classical noise, such as acoustic noise, phase noise and amplitude noise of lasers, and to lock the interferometer at the white-light position that corresponds to a nearly zero path-length difference. Here, we report an interferometer with an inserted acousto-optic modulator (AOM). It is noise immune and lock-free in principle. The experiments show that the new interferometer is able to measure cold atoms for more than 30 minutes and reduce the phase noise by about 30 dB.

Optics Express•Aug 28, 2020•2 citations

Dispersion cancellation in a triple Laue interferometer

Hartmut Lemmel

The concept of dispersion cancellation has been established in light optics to improve the resolution of interferometric measurements on dispersive media. Odd order dispersion cancellation allows to measure phase shifts without defocusing the interferometer due to wave packet displacements, while even order dispersion cancellation allows to measure time lags without losing resolution due to wave packet spreading. We report that either type of dispersion cancellation can be realized very easily in a triple Laue interferometer. Such interferometers are Mach–Zehnder interferometers based on Bragg diffraction, and are commonly used for neutrons and x-rays. Although the first x-ray interferometer was built nearly five decades ago, the feature of dispersion cancellation hasnʼt been recognized so far because the concept was hardly known in the neutron and x-ray community. However, it explains right away the surprising decoupling of phase shift and spatial displacement that we have discovered recently in neutron interferometry (Lemmel and Wagh 2010 Phys. Rev. A 82 033626). Furthermore, this article might inspire the light optics community to consider whether a triple Laue interferometer for laser light would be useful and feasible. We explain how dispersion cancellation works in neutron interferometry, and we describe the setup rigorously by solving the Schrodinger equation and by calculating the path integral. We point out, that the latter has to be evaluated with special care since in our setup the beam trajectory moves with respect to the crystal lattice of the interferometer.

Journal of Optics•Sep 4, 2014•1 citation

Quantum Limited DPSK Receivers with Optical Mach-Zehnder Interferometer Demodulation

Xiupu Zhang, Zhang, Guodong

We present an analysis of quantum-limited DPSK receivers with optical Mach-Zehnder interferometer (MZI) demodulation. It is shown for the first time that the quantum limits for DPSK/MZI receivers with single-port and balanced detections exactly differ from 3-dB in receiver sensitivity, obtained by both Poisson and Gaussian noise statistics.

arXiv:physics/0410077•Oct 12, 2004•0 citations

Feedback Stabilization of Optical Interferometer.

R. H. Nakat

An experimental study was carried out on the performance of a feedback stabilization scheme for optical interferometers. Optical interferometers are susceptible to acoustic noise which translates into path length fluctuations in the interferometer arms. These fluctuations induce phase noise, resulting in amplitude fluctuations on the interferometer output. The experiment was performed on a Mach-Zehnder homodyne interferometer where a RMS noise reduction of 23 dB was observed. The stabilization scheme has application to other interferometer configurations. In the future, it will be applied to stabilize cavities used in the squeezed state generation of light. (Author)

•Feb 1, 1985•0 citations
We have demonstrated the practical feasibility of a displacement- and frequency-noise-free laser interferometer (DFI) by partially implementing a recently proposed optical configuration using bi-directional Mach-Zehnder interferometers (MZIs). The noise cancellation efficiency was evaluated by comparing the displacement noise spectrum of the MZIs and the DFI, demonstrating up to 50 dB of noise cancellation. In addition, the possible extension of DFI as QND device is explored.
Displacement-noise-free interferometer (DFI) has developed for gravitational-wave (GW) detection free from any kind of displacement noise, which limits sensitivity of conventional laser interferometer GW detectors. The DFI mechanism can be also applied to quantum radiation pressure noise (RPN) in principle, and thus DFI allows ultrasensitive sensing beyond the so-called standard quantum limit. Namely, DFI can be a quantum-non-demolition (QND) measurement device for GW detection. The goal of this study is to examine the QND characteristics by cancelling RPN after observing it. Since not only obtaining the two signals which have same displacement information on the mirrors for the DFI system but amplifying the incident laser power to observe RPN are required for the experiment, I contrived a new optical design, a bidirectional triangular ring cavity DFI (RC-DFI). In this thesis, I introduced superiority of the optical system as compared to Mach-Zehnder type, and furthermore I demonstrated length control experiment of the cavity for verifying whether the noise cancellation ability on the above optical system will be still confirmed. Key Words: Gravitational-wave, Displacement-noise-free interferometry, Quantum-non-demolition measurement
Current laser-interferometric gravitational wave detectors suffer from a fundamental limit to their precision due to the displacement noise of optical elements contributed by various sources. Several schemes for displacement noise-free interferometers (DFI) have been proposed to mitigate their effects. The idea behind these schemes is similar to decoherence-free subspaces in quantum sensing; i.e., certain modes contain information about the gravitational waves but are insensitive to the mirror motion (displacement noise). We derive quantum precision limits for general DFI schemes, including optimal measurement basis and optimal squeezing schemes. We introduce a triangular cavity DFI scheme and apply our general bounds to it. Precision analysis of this scheme with different noise models shows that the DFI property leads to interesting sensitivity profiles and improved precision due to noise mitigation and larger gain from squeezing.
A novel noise-suppressing and lock-free interferometer is proposed and experimentally demonstrated in the study of the quantum non-destructive (QND) interaction of cold atoms. A QND measurement based on far-off resonant dispersive probing is usually carried out by a Mach-Zehnder type interferometer. It is an experimental challenge in its own right to reduce the classical noise, such as acoustic noise, phase noise and amplitude noise of lasers, and to lock the interferometer at the white-light position that corresponds to a nearly zero path-length difference. Here, we report an interferometer with an inserted acousto-optic modulator (AOM). It is noise immune and lock-free in principle. The experiments show that the new interferometer is able to measure cold atoms for more than 30 minutes and reduce the phase noise by about 30 dB.
The concept of dispersion cancellation has been established in light optics to improve the resolution of interferometric measurements on dispersive media. Odd order dispersion cancellation allows to measure phase shifts without defocusing the interferometer due to wave packet displacements, while even order dispersion cancellation allows to measure time lags without losing resolution due to wave packet spreading. We report that either type of dispersion cancellation can be realized very easily in a triple Laue interferometer. Such interferometers are Mach–Zehnder interferometers based on Bragg diffraction, and are commonly used for neutrons and x-rays. Although the first x-ray interferometer was built nearly five decades ago, the feature of dispersion cancellation hasnʼt been recognized so far because the concept was hardly known in the neutron and x-ray community. However, it explains right away the surprising decoupling of phase shift and spatial displacement that we have discovered recently in neutron interferometry (Lemmel and Wagh 2010 Phys. Rev. A 82 033626). Furthermore, this article might inspire the light optics community to consider whether a triple Laue interferometer for laser light would be useful and feasible. We explain how dispersion cancellation works in neutron interferometry, and we describe the setup rigorously by solving the Schrodinger equation and by calculating the path integral. We point out, that the latter has to be evaluated with special care since in our setup the beam trajectory moves with respect to the crystal lattice of the interferometer.
An experimental study was carried out on the performance of a feedback stabilization scheme for optical interferometers. Optical interferometers are susceptible to acoustic noise which translates into path length fluctuations in the interferometer arms. These fluctuations induce phase noise, resulting in amplitude fluctuations on the interferometer output. The experiment was performed on a Mach-Zehnder homodyne interferometer where a RMS noise reduction of 23 dB was observed. The stabilization scheme has application to other interferometer configurations. In the future, it will be applied to stabilize cavities used in the squeezed state generation of light. (Author)