Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Technical Physics

Magnetometer based on a pair of symmetric transitions in the 87Rb hyperfine structure

Evgenii B. Aleksandrov, Anton K. Vershovskii, Anatoly S. Pazgalev

Published Jul 1, 2006• 15 citations
Publisher

Abstract

A new version of the fast optically pumped magnetometer, an optically pumped balanced quantum magnetometer, built around a pair of symmetric transitions in the hyperfine structure of the 87 Rb ground state is implemented for the first time. The noise-limited sensitivity of the prototype in terms of the variance is 6 pT for a measurement time of 0.1 s. The basic advantages of the new magnetometer are the absence of dead zones when it changes orientation relative to the magnetic field and an extremely low sensitivity to the drift of pumping parameters.

DOI
10.1134/s1063784206070176

Related papers

Magnetometer without “Dead Zones” for Receiving Magnetic Induction Signals

Ермак Сергей Викторович, Roman Kuzmin, Olga Ermak +1 more

The article presents the results of a study of the possibility of using a quantum magnetometer on transitions in the hyperfine structure of rubidium- 87 atoms. A laboratory setup was assembled that implements a quantum magnetometer on transitions in the hyperfine structure of rubidium- 87 atoms placed in a small cell with an antirelaxation coating of the walls. Using the magnetometer, variable magnetic fields simulating magnetoinductive communication signals were received. The bandwidth of the magnetometer was measured, amounting to $\mathbf{1 6 0 ~ H z}$ at a level of $\mathbf{0. 7 0 7}$. Various cases of mutual orientation of constant and variable magnetic fields were considered. The possibility of receiving signals regardless of their direction was demonstrated, and a conclusion was made about the advantage of using a quantum magnetometer on transitions in the hyperfine structure of rubidium- 87 atoms in comparison with an Mz-type quantum magnetometer on low-frequency Zeeman transitions.

International Conference on Electrical Engineering and Photonics (EExPolytech)•Oct 16, 2025•0 citations

The design of a Λ-HFS magnetometer

Anton K. Vershovskii, Anatoly S. Pazgalev, Evgenii B. Aleksandrov

The design of a new quantum magnetometer for geomagnetic fields, an outgrowth of the idea of the so-called HFS magnetometer that uses microwave transitions between hyperfine sublevels of alkaline atoms, is presented. In contrast to the ordinary HFS magnetometer, which measures the frequency difference of two independent transitions, the new Λ-HFS magnetometer is based on the excitation of two transitions with a common level. The design under discussion retains the principal advantages of the prototype (negligible systematic errors and the absence of dead zones for a single sensor), with the electronic circuits being simplified significantly and the requirements on the short-term frequency stability of the reference oscillator being relaxed substantially. An analysis of the new scheme is based on the solution of the equation for the density matrix of a multilevel system without constraints on the power of the microwave fields.

Technical Physics•Jan 1, 2000•7 citations

Spin projection noise and the magnetic sensitivity of optically pumped magnetometers

K. Mouloudakis, V. Koutrouli, Iannis K. Kominis +2 more

Present protocols for obtaining the ultimate magnetic sensitivity of optically pumped magnetometers (OPMs) utilizing alkali-metal ensembles rely on uncorrelated atoms in stretched states. A new approach for calculating the spin projection noise (SPN)-limited signal to noise ratio (SNR) and the magnetic sensitivity of OPMs is proposed. Our model is based solely on the mean-field density matrix dynamics and in contrast to previous models, it applies to both low and high field regimes, it takes into account the degree of spin polarization, the intra- and interhyperfine correlations, the decoherence processes, the atom-light coupling and the effects of the spin dynamics on the spin-noise spectra. Fine tuning of the probe frequency allow us to explore different hyperfine states and ground-state correlations. Especially in the spin-exchange-relaxation-free (SERF) regime, alongside the magnetic resonance narrowing and the increased number density, hallmarks of SERF magnetometers, we report on a new SERF feature; the reduction of spin-projection noise at the spin precession frequency as a consequence of strongly-correlated hyperfine spins that attenuate and redistribute SPN when properly probed.

arXiv:2402.10746•Feb 16, 2024•2 citations

Research on an pump-probe rubidium magnetometer

Zhiguo Wang, Luo Hui, Fan Zhenfang +1 more

In order to measure a weak alternating magnetic field, an optically-pumped Rb magnetometer based on pump-probe structure is investigated and demonstrated. The pumping light and probing light propagate along the z axis and x axis, respectively. A constant polarization magnetic field along the pumping light is applied, which not only stabilizes the polarization of Rb atoms but also tunes resonance frequency of Rb atoms. When a weak alternating magnetic field is applied perpendicularly to the constant magnetic field, the magnetic moment will tip off the z axis and rotate around the z axis. And then the polarization plane of probing light is modulated correspondingly. The x component of the magnetic moment can be obtained with a balanced detector. As a result, a signal proportional to weak alternating magnetic field can be obtained.In order to obtain the magnetic response of the magnetometer, we analyze the signal amplitude as a function of polarization magnetic field strength B0 and transverse relaxation time 2 with numerical simulation. The amplitude-frequency response of the magnetometer is determined mainly by two parameters, namely cutoff frequency c=1/2 and resonance frequency 0= B0, where is the gyromagnetic ratio of Rb atom. At low frequency, that is a0 and a 0c2, the magnetometer has a flat response, here a is the frequency of the weak alternating magnetic field. If 0c, the signal amplitude will be large for large 0 or small c. For a given c, the peak response appears at 0=c. In the vicinity of resonance frequency, if c0, a peak will appear and if c 0, no peak occurs. At high frequency, the amplitude will decrease with the increase of a.We verify the above analyses in experiment. A vapor cell with a short transverse relaxation time is used to obtain large frequency response bandwidth. Through optimizing the powers and frequencies of pumping laser and probing laser, high polarization and detection sensitivity of atomic spin can be obtained. Moreover, through choosing an appropriate polarization magnetic field, the magnetometer can be maximally sensitive to the magnetic field to be measured. The experimental results show that the magnetometer has a sensitivity of about m 0.2; pT/HzHz and bandwidth of about 3.5 kHz. It can be used to detect low field magnetic resonance and high frequency abnormal physical phenomena.

Acta Physica Sinica•Jan 1, 2016•4 citations

Sensitive detection of magnetic fields including their orientation with a magnetometer based on atomic phase coherence

Hwang Lee, Michael Fleischhauer, Marlan O. Scully

An optical magnetometer based on electromagnetically induced transparency is analyzed. Utilizing the different orientation characteristics for different field polarizations, the magnitude and orientation of an applied magnetic field can be measured. As a model system we consider the sodium ${D}_{1}$ transition taking into account hyperfine structure and optical pumping effects.

Physical Review A•Sep 1, 1998•72 citations

High sensitivity closed-loop Rb optically pumped magnetometer for measuring nuclear magnetization

Siran Li, Danyue Ma, Kun Wang +5 more

Rb optically pumped magnetometer (OPM) based on electron paramagnetic resonance (EPR) show advantages to measure the nuclear magnetization and have succeeded in fundamental physics and rotation sensing, etc . The magnetometry sensitivity is a key performance of these Rb OPMs which should be improved. In this study, a high sensitivity Rb OPM is demonstrated theoretically and experimentally. To improve the sensitivity, acousto-optic modulation based on balanced detection is applied to suppress the probe noises. Compared with the conventional optical rotation detection for this OPM configuration, the probe noise shows a significant suppression especially in low frequencies. Eventually, a simultaneous dual-axis transverse measurement with 30 fT/Hz 1/2 sensitivity is achieved in a 200 Hz bandwidth and a 250nT linear working range. In addition, we utilize a closed-loop feedback to improve the stability and enlarge the transverse measurement range to 10µT order of magnitude while maintain the open-loop performances. A quasi-static magnetic field measurement can also be achieved in the longitudinal direction in the closed-loop mode. This OPM can serve for the nuclear magnetization measurement with a high sensitivity especially in environments with a large magnitude of the external magnetic field.

Optics Express•Nov 16, 2022•6 citations
A new version of the fast optically pumped magnetometer, an optically pumped balanced quantum magnetometer, built around a pair of symmetric transitions in the hyperfine structure of the 87 Rb ground state is implemented for the first time. The noise-limited sensitivity of the prototype in terms of the variance is 6 pT for a measurement time of 0.1 s. The basic advantages of the new magnetometer are the absence of dead zones when it changes orientation relative to the magnetic field and an extremely low sensitivity to the drift of pumping parameters.
The article presents the results of a study of the possibility of using a quantum magnetometer on transitions in the hyperfine structure of rubidium- 87 atoms. A laboratory setup was assembled that implements a quantum magnetometer on transitions in the hyperfine structure of rubidium- 87 atoms placed in a small cell with an antirelaxation coating of the walls. Using the magnetometer, variable magnetic fields simulating magnetoinductive communication signals were received. The bandwidth of the magnetometer was measured, amounting to 160 Hz\mathbf{1 6 0 ~ H z}160 Hz at a level of 0.707\mathbf{0. 7 0 7}0.707. Various cases of mutual orientation of constant and variable magnetic fields were considered. The possibility of receiving signals regardless of their direction was demonstrated, and a conclusion was made about the advantage of using a quantum magnetometer on transitions in the hyperfine structure of rubidium- 87 atoms in comparison with an Mz-type quantum magnetometer on low-frequency Zeeman transitions.
The design of a new quantum magnetometer for geomagnetic fields, an outgrowth of the idea of the so-called HFS magnetometer that uses microwave transitions between hyperfine sublevels of alkaline atoms, is presented. In contrast to the ordinary HFS magnetometer, which measures the frequency difference of two independent transitions, the new Λ-HFS magnetometer is based on the excitation of two transitions with a common level. The design under discussion retains the principal advantages of the prototype (negligible systematic errors and the absence of dead zones for a single sensor), with the electronic circuits being simplified significantly and the requirements on the short-term frequency stability of the reference oscillator being relaxed substantially. An analysis of the new scheme is based on the solution of the equation for the density matrix of a multilevel system without constraints on the power of the microwave fields.
Present protocols for obtaining the ultimate magnetic sensitivity of optically pumped magnetometers (OPMs) utilizing alkali-metal ensembles rely on uncorrelated atoms in stretched states. A new approach for calculating the spin projection noise (SPN)-limited signal to noise ratio (SNR) and the magnetic sensitivity of OPMs is proposed. Our model is based solely on the mean-field density matrix dynamics and in contrast to previous models, it applies to both low and high field regimes, it takes into account the degree of spin polarization, the intra- and interhyperfine correlations, the decoherence processes, the atom-light coupling and the effects of the spin dynamics on the spin-noise spectra. Fine tuning of the probe frequency allow us to explore different hyperfine states and ground-state correlations. Especially in the spin-exchange-relaxation-free (SERF) regime, alongside the magnetic resonance narrowing and the increased number density, hallmarks of SERF magnetometers, we report on a new SERF feature; the reduction of spin-projection noise at the spin precession frequency as a consequence of strongly-correlated hyperfine spins that attenuate and redistribute SPN when properly probed.
In order to measure a weak alternating magnetic field, an optically-pumped Rb magnetometer based on pump-probe structure is investigated and demonstrated. The pumping light and probing light propagate along the z axis and x axis, respectively. A constant polarization magnetic field along the pumping light is applied, which not only stabilizes the polarization of Rb atoms but also tunes resonance frequency of Rb atoms. When a weak alternating magnetic field is applied perpendicularly to the constant magnetic field, the magnetic moment will tip off the z axis and rotate around the z axis. And then the polarization plane of probing light is modulated correspondingly. The x component of the magnetic moment can be obtained with a balanced detector. As a result, a signal proportional to weak alternating magnetic field can be obtained.In order to obtain the magnetic response of the magnetometer, we analyze the signal amplitude as a function of polarization magnetic field strength B0 and transverse relaxation time 2 with numerical simulation. The amplitude-frequency response of the magnetometer is determined mainly by two parameters, namely cutoff frequency c=1/2 and resonance frequency 0= B0, where is the gyromagnetic ratio of Rb atom. At low frequency, that is a0 and a 0c2, the magnetometer has a flat response, here a is the frequency of the weak alternating magnetic field. If 0c, the signal amplitude will be large for large 0 or small c. For a given c, the peak response appears at 0=c. In the vicinity of resonance frequency, if c0, a peak will appear and if c 0, no peak occurs. At high frequency, the amplitude will decrease with the increase of a.We verify the above analyses in experiment. A vapor cell with a short transverse relaxation time is used to obtain large frequency response bandwidth. Through optimizing the powers and frequencies of pumping laser and probing laser, high polarization and detection sensitivity of atomic spin can be obtained. Moreover, through choosing an appropriate polarization magnetic field, the magnetometer can be maximally sensitive to the magnetic field to be measured. The experimental results show that the magnetometer has a sensitivity of about m 0.2; pT/HzHz and bandwidth of about 3.5 kHz. It can be used to detect low field magnetic resonance and high frequency abnormal physical phenomena.
An optical magnetometer based on electromagnetically induced transparency is analyzed. Utilizing the different orientation characteristics for different field polarizations, the magnitude and orientation of an applied magnetic field can be measured. As a model system we consider the sodium D1{D}_{1}D1​ transition taking into account hyperfine structure and optical pumping effects.
Rb optically pumped magnetometer (OPM) based on electron paramagnetic resonance (EPR) show advantages to measure the nuclear magnetization and have succeeded in fundamental physics and rotation sensing, etc . The magnetometry sensitivity is a key performance of these Rb OPMs which should be improved. In this study, a high sensitivity Rb OPM is demonstrated theoretically and experimentally. To improve the sensitivity, acousto-optic modulation based on balanced detection is applied to suppress the probe noises. Compared with the conventional optical rotation detection for this OPM configuration, the probe noise shows a significant suppression especially in low frequencies. Eventually, a simultaneous dual-axis transverse measurement with 30 fT/Hz 1/2 sensitivity is achieved in a 200 Hz bandwidth and a 250nT linear working range. In addition, we utilize a closed-loop feedback to improve the stability and enlarge the transverse measurement range to 10µT order of magnitude while maintain the open-loop performances. A quasi-static magnetic field measurement can also be achieved in the longitudinal direction in the closed-loop mode. This OPM can serve for the nuclear magnetization measurement with a high sensitivity especially in environments with a large magnitude of the external magnetic field.