Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review A

Sensitive detection of magnetic fields including their orientation with a magnetometer based on atomic phase coherence

Hwang Lee, Michael Fleischhauer, Marlan O. Scully

Published Sep 1, 1998• 72 citations
Publisher

Abstract

An optical magnetometer based on electromagnetically induced transparency is analyzed. Utilizing the different orientation characteristics for different field polarizations, the magnitude and orientation of an applied magnetic field can be measured. As a model system we consider the sodium ${D}_{1}$ transition taking into account hyperfine structure and optical pumping effects.

DOI
10.1103/physreva.58.2587

Related papers

Vector magnetometry based on electromagnetically induced transparency in linearly polarized light

Valeriy I. Yudin, А. В. Тайченачев, Yaroslav O. Dudin +3 more

We develop a generalized principle of electromagnetically induced transparency (EIT) vector magnetometry based on high-contrast EIT resonances and the symmetry of atom-light interaction in the linearly polarized bichromatic fields. Operation of such vector magnetometer on the ${D}_{1}$ line of $^{87}\mathrm{Rb}$ has been demonstrated. The proposed compass-magnetometer has an increased immunity to shifts produced by quadratic Zeeman and ac-Stark effects, as well as by atom-buffer gas and atom-atom collisions. In our proof-of-principle experiment the detected angular sensitivity to magnetic field orientation is ${10}^{\ensuremath{-}3}$ deg/Hz${}^{1/2}$, which is limited by laser intensity fluctuations, light polarization quality, and magnitude of the magnetic field.

arXiv:1004.3969•Physical Review A•Sep 13, 2010•113 citations

Vector Magnetometer Using Rb Vapor

Kevin C. Cox

This project demonstrates an optical method for measuring the strength and direction of a magnetic field using electromagnetically induced transparency (EIT) in rubidium vapor. In rubidium atoms, the Zeeman effect causes atomic states to shift when an external magnetic field is applied. The magnitude of these shifts, and consequently the strength of the magnetic field, can be measured by recording electromagnetically induced transparency resonances with tuned laser fields. Furthermore, since the atom's interaction with the laser field is dependent on the direction of the magnetic field and the laser polarization, we are able to determine the direction as well as the strength of the magnetic field by analyzing relative intensities of EIT resonances. With a feasible precision down to 10 picoTesla and the possibility of complete field mapping, this magnetometer can be useful for medical, geophysical, and materials testing applications.

•May 4, 2011•0 citations

Orientational effects on the amplitude and phase of polarimeter signals in double-resonance atomic magnetometry

Stuart J. Ingleby, Carolyn O’Dwyer, Paul F. Griffin +2 more

Double-resonance optically pumped magnetometry can be used to measure static magnetic fields with high sensitivity by detecting a resonant atomic spin response to a small oscillating field perturbation. Determination of the resonant frequency yields a scalar measurement of static field $({B}_{0})$ magnitude. We present calculations and experimental data showing that the on-resonance polarimeter signal of light transmitted through an atomic vapor in arbitrarily oriented ${B}_{0}$ may be modeled by considering the evolution of alignment terms in atomic polarization. We observe that the amplitude and phase of the magnetometer signal are highly dependent upon ${B}_{0}$ orientation and present precise measurements of the distribution of these parameters over the full $4\ensuremath{\pi}$ solid angle.

arXiv:1707.04418•Physical Review A•Jul 28, 2017•24 citations

Zero-field optical magnetometer based on spin alignment

Adil Meraki, L. Elson, N.J. Ho +4 more

Optically pumped magnetometers are important instruments for imaging biological magnetic signals without the need for cryogenic cooling. These magnetometers are presently available in the commercial market and utilize the principles of atomic alignment or orientation, enabling remarkable sensitivity and precision in the measurement of magnetic fields. This research focuses on utilizing a spin-aligned atomic ensemble for magnetometry at zero field. An approach is introduced which involves evaluating how the linear polarization of light rotates as it passes through the atomic vapor to null the magnetic field. Analytical expressions are derived for the resulting spin alignment and photodetection signals. Experimental results are provided, demonstrating good agreement with the theoretical predictions. The sensitivity and bandwidth of the magnetometer are characterized based on the detected polarization rotation signal. Lastly, the practical utility of the magnetometer for medical applications is demonstrated by successfully detecting a synthetic cardiac signal.

arXiv:2308.12233•Physical Review A•Dec 11, 2023•19 citations

Optical Magnetometer Incorporating Photonic Crystals

Igor K. Kulikov, Lucia Florescu

According to a proposal, photonic crystals would be used to greatly increase the sensitivities of optical magnetometers that are already regarded as ultrasensitive. The proposal applies, more specifically, to a state-of-the-art type of quantum coherent magnetometer that exploits the electromagnetically-induced-transparency (EIT) method for determining a small change in a magnetic field indirectly via measurement of the shift, induced by that change, in the hyperfine levels of resonant atoms exposed to the field.

•Oct 1, 2007•0 citations

Quantum sensitivity limits of an optical magnetometer based on atomic phase coherence

Michael Fleischhauer, Marlan O. Scully

An optical magnetometer based on atomic coherence effects is analyzed using a quantum Langevin approach. The large dispersion of a phase-coherent atomic medium (``phaseonium'') at a point of vanishing absorption is used to detect magnetic level shifts via optical phase measurements in a Mach-Zehnder interferometer with sensitivities potentially superior to state-of-the-art devices. Effects of Doppler broadening and fluctuations of the driving field are discussed and a comparison to standard optical-pumping magnetometers is made.

Physical Review A•Mar 1, 1994•142 citations
An optical magnetometer based on electromagnetically induced transparency is analyzed. Utilizing the different orientation characteristics for different field polarizations, the magnitude and orientation of an applied magnetic field can be measured. As a model system we consider the sodium D1{D}_{1}D1​ transition taking into account hyperfine structure and optical pumping effects.
We develop a generalized principle of electromagnetically induced transparency (EIT) vector magnetometry based on high-contrast EIT resonances and the symmetry of atom-light interaction in the linearly polarized bichromatic fields. Operation of such vector magnetometer on the D1{D}_{1}D1​ line of 87Rb^{87}\mathrm{Rb}87Rb has been demonstrated. The proposed compass-magnetometer has an increased immunity to shifts produced by quadratic Zeeman and ac-Stark effects, as well as by atom-buffer gas and atom-atom collisions. In our proof-of-principle experiment the detected angular sensitivity to magnetic field orientation is ${10}^{\ensuremath{-}3}$ deg/Hz1/2{}^{1/2}1/2, which is limited by laser intensity fluctuations, light polarization quality, and magnitude of the magnetic field.
This project demonstrates an optical method for measuring the strength and direction of a magnetic field using electromagnetically induced transparency (EIT) in rubidium vapor. In rubidium atoms, the Zeeman effect causes atomic states to shift when an external magnetic field is applied. The magnitude of these shifts, and consequently the strength of the magnetic field, can be measured by recording electromagnetically induced transparency resonances with tuned laser fields. Furthermore, since the atom's interaction with the laser field is dependent on the direction of the magnetic field and the laser polarization, we are able to determine the direction as well as the strength of the magnetic field by analyzing relative intensities of EIT resonances. With a feasible precision down to 10 picoTesla and the possibility of complete field mapping, this magnetometer can be useful for medical, geophysical, and materials testing applications.
Double-resonance optically pumped magnetometry can be used to measure static magnetic fields with high sensitivity by detecting a resonant atomic spin response to a small oscillating field perturbation. Determination of the resonant frequency yields a scalar measurement of static field (B0)({B}_{0})(B0​) magnitude. We present calculations and experimental data showing that the on-resonance polarimeter signal of light transmitted through an atomic vapor in arbitrarily oriented B0{B}_{0}B0​ may be modeled by considering the evolution of alignment terms in atomic polarization. We observe that the amplitude and phase of the magnetometer signal are highly dependent upon B0{B}_{0}B0​ orientation and present precise measurements of the distribution of these parameters over the full $4\ensuremath{\pi}$ solid angle.
Optically pumped magnetometers are important instruments for imaging biological magnetic signals without the need for cryogenic cooling. These magnetometers are presently available in the commercial market and utilize the principles of atomic alignment or orientation, enabling remarkable sensitivity and precision in the measurement of magnetic fields. This research focuses on utilizing a spin-aligned atomic ensemble for magnetometry at zero field. An approach is introduced which involves evaluating how the linear polarization of light rotates as it passes through the atomic vapor to null the magnetic field. Analytical expressions are derived for the resulting spin alignment and photodetection signals. Experimental results are provided, demonstrating good agreement with the theoretical predictions. The sensitivity and bandwidth of the magnetometer are characterized based on the detected polarization rotation signal. Lastly, the practical utility of the magnetometer for medical applications is demonstrated by successfully detecting a synthetic cardiac signal.
According to a proposal, photonic crystals would be used to greatly increase the sensitivities of optical magnetometers that are already regarded as ultrasensitive. The proposal applies, more specifically, to a state-of-the-art type of quantum coherent magnetometer that exploits the electromagnetically-induced-transparency (EIT) method for determining a small change in a magnetic field indirectly via measurement of the shift, induced by that change, in the hyperfine levels of resonant atoms exposed to the field.
An optical magnetometer based on atomic coherence effects is analyzed using a quantum Langevin approach. The large dispersion of a phase-coherent atomic medium (``phaseonium'') at a point of vanishing absorption is used to detect magnetic level shifts via optical phase measurements in a Mach-Zehnder interferometer with sensitivities potentially superior to state-of-the-art devices. Effects of Doppler broadening and fluctuations of the driving field are discussed and a comparison to standard optical-pumping magnetometers is made.