Fiber Bragg gratings for atom chips

Steve Helsby, Costantino Corbari, Morten Ibsen, Péter Horák, Peter G. Kazansky

Published Jan 17, 2007• 3 citations
Publisher

Abstract

We discuss the fabrication and characterization of fiber Fabry-Perot cavities developed for integrated atom detection on the atom chip. Investigations show that the cavities are suitable for the detection of small numbers of atoms, with restrictions due to absorption in the Bragg gratings. We show that a significant reduction in these absorption losses can be attained by thermal annealing, removing any material limitations to single-atom detection.

DOI
10.1103/physreva.75.013618

Related papers

Fiber optics for quantum computers

Steve Helsby, Hebe Powell, Péter Horák +2 more

Abstract: We describe schemes for the integration of miniature optical components onto Atom Chips, for the manipulation and detection of ultra-cold atoms. Our intention is to build detectors sensitive enough to accurately detect single atoms. Two approaches are discussed: simple fluorescence detection and the use of a resonant cavity. Theory predicts that cavities with F>100 should be sufficient to obtain signal to noise ratios high enough to detect single atoms. The first micro cavities were demonstrated using mirrors formed by cleaved fiber ends coated with a stick-on dielectric coating to give F ∼100. A more successful approach involves the full integration of the mirrors and fibers by using Bragg gratings written into the fiber core: it has been possible to form gap cavities with F ~ 150. 1.

•Jan 1, 2004•0 citations

Single atom detection on an atom chip with integrated optics

Marco Wilzbach

The subject of this thesis is the miniaturization and integration of detectors for the detection of single rubidium atoms on an atom chip. For this purpose three different detectors were developed for atom detection by absorption or fluorescence: i) A fluorescence detector was realized by mounting a tapered lensed fiber perpendicular to a collection fiber. ii) An absorption detector was built by placing a multi-mode fiber in-line with a tapered lensed fiber. iii) A tunable cavity detector was built from two single mode fibers mounted on the chip surface. To mount the detectors on the planar surface of the atom chip retaining structures by means of lithographical techniques were developed. Those structures allow a very accurate and stable passive fiber alignment. To test the individual detectors an atomic ensemble of thermal rubidium atoms was prepared in a magneto-optical trap. Then the atoms were transferred into magnetic micro-traps of the atom chip and were guided to one of the detectors. Each integrated detector has been evaluated by several characterization measurements. With the fluorescence detector the highest single atom detection efficiency of 54\\% was attained. Thereby it was possible to perform quantitative measurements for the magnetically guided atoms on a single atom level and to study fundamental properties of the confined atoms.

•Jan 1, 2007•0 citations

Detecting Neutral Atoms on an Atom Chip

Marco Wilzbach, Albrecht Haase, Michael Schwarz +8 more

This chapter contains sections titled: Introduction Detecting Single Atoms Measuring the Scattered Light: Fluorescence Detection Measuring the Driving Field Absorption on Resonance Refraction Cavities Absorption on Resonance Refraction Many Atoms in a Cavity Concentric Cavity Miniaturization Properties of Fiber Cavities Loss Mechanisms for a Cavity Losses due to the Gap Length Losses due to Transversal Misalignment Losses due to Angular Misalignment Fresnel Reflections Other Fiber Optical Components for the Atom Chip Fluorescence and Absorption Detectors A Single Mode Tapered Lensed Fiber Dipole Trap Integration of Fibers on the Atom Chip Building Fiber Cavities The SU-8 Resist Test of the SU-8 Structure Pilot Test for Atom Detection with Small Waists Dropping Atoms through a Concentric Cavity Detecting Magnetically Guided Atoms Conclusion References

Wiley eBooks•Jan 26, 2007•1 citation

Thermal tuning of a fiber-integrated Fabry-Pérot cavity

Clemens Singer, Alexander Goetz, Adarsh S. Prasad +3 more

Here, we present the thermal tuning capability of an alignment-free, fiber-integrated Fabry-Pérot cavity. The two mirrors are made of fiber Bragg gratings that can be individually temperature stabilized and tuned. We show the temperature tuning of the resonance wavelength of the cavity without any degradation of the finesse and the tuning of the individual stop bands of the fiber Bragg gratings. This not only permits for the cavity's finesse to be optimized post-fabrication but also makes this cavity applicable as a narrowband filter with a FWHM spectral width of 0.07 ± 0.02 pm and a suppression of more than -15 dB that can be wavelength tuned. Further, in the field of quantum optics, where strong light-matter interactions are desirable, quantum emitters can be coupled to such a cavity and the cavity effect can be reversibly omitted and re-established. This is particularly useful when working with solid-state quantum emitters where such a reference measurement is often not possible once an emitter has been permanently deposited inside a cavity.

arXiv:2105.12560•Optics Express•Aug 10, 2021•8 citations

Detecting neutral atoms on an atom chip

M. Wilzbach, A. Haase, M. Schwarz +8 more

Abstract Detecting single atoms (qubits) is a key requirement for implementing quantum information processing on an atom chip. The detector should ideally be integrated on the chip. Here we present and compare different methods capable of detecting neutral atoms on an atom chip. After a short introduction to fluorescence and absorption detection we discuss cavity enhanced detection of single atoms. In particular we concentrate on optical fiber based detectors such as fiber cavities and tapered fiber dipole traps. We discuss the various constraints in building such detectors in detail along with the current implementations on atom chips. Results from experimental tests of fiber integration are also described. In addition we present a pilot experiment for atom detection using a concentric cavity to verify the required scaling.

arXiv:physics/0608189•Fortschritte der Physik•Aug 1, 2006•12 citations

Stable fiber-based Fabry-Pérot cavity

T. Steinmetz, Yves Colombe, D. Hunger +4 more

The development of a fiber-based, tunable optical cavity with open access is reported. The cavity is of the Fabry-Pérot type and is formed with miniature spherical mirrors positioned on the end of single- or multimode optical fibers by a transfer technique, which involves lifting a high-quality mirror from a smooth convex substrate, either a ball lens or microlens. The cavities typically have a finesse of ∼1000 and a mode volume of 600μm3. The detection of small ensembles of cold Rb atoms guided through such a cavity on an atom chip is demonstrated.

arXiv:physics/0606231•Applied Physics Letters•Sep 11, 2006•96 citations
We discuss the fabrication and characterization of fiber Fabry-Perot cavities developed for integrated atom detection on the atom chip. Investigations show that the cavities are suitable for the detection of small numbers of atoms, with restrictions due to absorption in the Bragg gratings. We show that a significant reduction in these absorption losses can be attained by thermal annealing, removing any material limitations to single-atom detection.
Abstract: We describe schemes for the integration of miniature optical components onto Atom Chips, for the manipulation and detection of ultra-cold atoms. Our intention is to build detectors sensitive enough to accurately detect single atoms. Two approaches are discussed: simple fluorescence detection and the use of a resonant cavity. Theory predicts that cavities with F>100 should be sufficient to obtain signal to noise ratios high enough to detect single atoms. The first micro cavities were demonstrated using mirrors formed by cleaved fiber ends coated with a stick-on dielectric coating to give F ∼100. A more successful approach involves the full integration of the mirrors and fibers by using Bragg gratings written into the fiber core: it has been possible to form gap cavities with F ~ 150. 1.
The subject of this thesis is the miniaturization and integration of detectors for the detection of single rubidium atoms on an atom chip. For this purpose three different detectors were developed for atom detection by absorption or fluorescence: i) A fluorescence detector was realized by mounting a tapered lensed fiber perpendicular to a collection fiber. ii) An absorption detector was built by placing a multi-mode fiber in-line with a tapered lensed fiber. iii) A tunable cavity detector was built from two single mode fibers mounted on the chip surface. To mount the detectors on the planar surface of the atom chip retaining structures by means of lithographical techniques were developed. Those structures allow a very accurate and stable passive fiber alignment. To test the individual detectors an atomic ensemble of thermal rubidium atoms was prepared in a magneto-optical trap. Then the atoms were transferred into magnetic micro-traps of the atom chip and were guided to one of the detectors. Each integrated detector has been evaluated by several characterization measurements. With the fluorescence detector the highest single atom detection efficiency of 54\\% was attained. Thereby it was possible to perform quantitative measurements for the magnetically guided atoms on a single atom level and to study fundamental properties of the confined atoms.
This chapter contains sections titled: Introduction Detecting Single Atoms Measuring the Scattered Light: Fluorescence Detection Measuring the Driving Field Absorption on Resonance Refraction Cavities Absorption on Resonance Refraction Many Atoms in a Cavity Concentric Cavity Miniaturization Properties of Fiber Cavities Loss Mechanisms for a Cavity Losses due to the Gap Length Losses due to Transversal Misalignment Losses due to Angular Misalignment Fresnel Reflections Other Fiber Optical Components for the Atom Chip Fluorescence and Absorption Detectors A Single Mode Tapered Lensed Fiber Dipole Trap Integration of Fibers on the Atom Chip Building Fiber Cavities The SU-8 Resist Test of the SU-8 Structure Pilot Test for Atom Detection with Small Waists Dropping Atoms through a Concentric Cavity Detecting Magnetically Guided Atoms Conclusion References
Here, we present the thermal tuning capability of an alignment-free, fiber-integrated Fabry-Pérot cavity. The two mirrors are made of fiber Bragg gratings that can be individually temperature stabilized and tuned. We show the temperature tuning of the resonance wavelength of the cavity without any degradation of the finesse and the tuning of the individual stop bands of the fiber Bragg gratings. This not only permits for the cavity's finesse to be optimized post-fabrication but also makes this cavity applicable as a narrowband filter with a FWHM spectral width of 0.07 ± 0.02 pm and a suppression of more than -15 dB that can be wavelength tuned. Further, in the field of quantum optics, where strong light-matter interactions are desirable, quantum emitters can be coupled to such a cavity and the cavity effect can be reversibly omitted and re-established. This is particularly useful when working with solid-state quantum emitters where such a reference measurement is often not possible once an emitter has been permanently deposited inside a cavity.
Abstract Detecting single atoms (qubits) is a key requirement for implementing quantum information processing on an atom chip. The detector should ideally be integrated on the chip. Here we present and compare different methods capable of detecting neutral atoms on an atom chip. After a short introduction to fluorescence and absorption detection we discuss cavity enhanced detection of single atoms. In particular we concentrate on optical fiber based detectors such as fiber cavities and tapered fiber dipole traps. We discuss the various constraints in building such detectors in detail along with the current implementations on atom chips. Results from experimental tests of fiber integration are also described. In addition we present a pilot experiment for atom detection using a concentric cavity to verify the required scaling.
The development of a fiber-based, tunable optical cavity with open access is reported. The cavity is of the Fabry-Pérot type and is formed with miniature spherical mirrors positioned on the end of single- or multimode optical fibers by a transfer technique, which involves lifting a high-quality mirror from a smooth convex substrate, either a ball lens or microlens. The cavities typically have a finesse of ∼1000 and a mode volume of 600μm3. The detection of small ensembles of cold Rb atoms guided through such a cavity on an atom chip is demonstrated.