Conference on Lasers and Electro-Optics

Efficient, low-noise, single-photon frequency conversion

Paulina S. Kuo, Jason S. Pelc, Oliver Slattery, Yong‐Su Kim, M. M. Fejer, Xiao Hong Tang

Published Jan 1, 2013• 1 citation
Publisher

Abstract

We demonstrate simultaneous low-noise and efficient frequency conversion in a periodically poled LiNbO3 waveguide with spectral filtering. We achieve >50% external conversion efficiency and 600 noise counts per second at peak conversion.
DOI
10.1364/cleo_qels.2013.jth2a.86

Related papers

Reducing noise in single-photon-level frequency conversion

Paulina S. Kuo, Jason S. Pelc, Oliver Slattery +3 more

We demonstrate low-noise and efficient frequency conversion by sum-frequency mixing in a periodically poled LiNbO(3) (PPLN) waveguide. Using a 1556 nm pump, 1302 nm photons are efficiently converted to 709 nm photons. We obtain 70% conversion efficiency in the PPLN waveguide and >50% external conversion efficiency with 600 noise counts per second at peak conversion with continuous-wave pumping. We simultaneously achieve low noise and high conversion efficiency by careful spectral filtering. We discuss the impact of low-noise frequency translation on single-photon upconversion detection and quantum information applications.

Optics Letters•Apr 9, 2013•65 citations

Ultra low dark-count-rate up-conversion single photon detector

Xiao Hong Tang, Lijun Ma, Oliver Slattery

We have demonstrated an ultra low noise up-conversion single photon detector using a periodically poled lithium niobate waveguide. The dark count rate of this detector is lower than 100 counts/second at 10% detection efficiency.

IEEE Photonics Society Annual Meeting•Nov 1, 2010•3 citations

Low noise single photon frequency upconversion using Ti-indiffused periodically-poled lithium niobate waveguides with efficient narrowband filtering

Zhenda Xie, Kai-Hong Luo, Harald Herrmann +2 more

We demonstrate single-photon frequency-upconversion using a titanium-infused periodically-poled lithium niobate waveguide by L-band erbium-doped fiber amplifier pump. Internal efficiencies up to 84.4% and dark-count rate of 44kHz are achieved with narrowband filtering down to 3.5GHz.

Conference on Lasers and Electro-Optics•Jan 1, 2015•1 citation

Single-photon detector based on frequency up-conversion in MgO-doped periodically-poled LiNbO3 waveguide: recordlow dark counts and detectable photons

Da Li, Yujie J. Ding, Ioulia B. Zotova +1 more

We have implemented a single-photon detector in the 1500-nm band based on frequency up-conversion in a MgO-doped periodically-poled LiNbO3 waveguide, with a record-low dark count rate and a record-low detectable signal photon rate.

Conference on Lasers and Electro-Optics•Jan 1, 2012•0 citations

Frequency up-conversion at the single-photon level in a periodically-poled lithium-niobate waveguide

Sarah Dugan, X. Li, Paul L. Voss +1 more

Using sum-frequency generation we fully up-convert signal photons at 1550 nm to 775 nm. Due to coupling and filtering losses at the output, overall quantum efficiency is /spl sime/3.4% with dark-count probability of 3%.

Quantum Electronics and Laser Science Conference•Dec 10, 2005•2 citations

Devices for frequency conversion of single and entangled photons

Jason S. Pelc, M. M. Fejer

Waveguides in periodically poled lithium niobate can be used for frequency up- and downconversion of quantum states of light.We discuss applications for single-photon detection, quantum communications, and limitations due to parasitic noise processes.

IEEE/LEOS Summer Topical Meetings•Jul 1, 2011•0 citations
We demonstrate low-noise and efficient frequency conversion by sum-frequency mixing in a periodically poled LiNbO(3) (PPLN) waveguide. Using a 1556 nm pump, 1302 nm photons are efficiently converted to 709 nm photons. We obtain 70% conversion efficiency in the PPLN waveguide and >50% external conversion efficiency with 600 noise counts per second at peak conversion with continuous-wave pumping. We simultaneously achieve low noise and high conversion efficiency by careful spectral filtering. We discuss the impact of low-noise frequency translation on single-photon upconversion detection and quantum information applications.