Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review A

Field-state measurement in a micromaser using retrodictive quantum theory

E.-K. Tan, John Jeffers, Stephen Mark Barnett

Published Apr 7, 2004• 6 citations
Publisher

Abstract

Injected two-level atoms, prepared and measured in various states, make an effective measurement of the cavity field of a micromaser prior to the injection of the atoms. In contrast to other existing literature on the micromaser, we have used the unconventional retrodictive quantum theory which allows us to calculate, in particular, the phase properties of the field state at an earlier time prior to the interaction with the injected atoms.

DOI
10.1103/physreva.69.043806

Related papers

Field-State Retrodiction in a Micromaser

E.-K. Tan

We have used retrodictive quantum theory to calculate the retrodictive initial field states of a micromaser for different combinations of prepared and measured atomic states. This method allows calculations of both the photon statistics and the off‐diagonal matrix elements, thus the phase information, of the cavity field prior to interaction with injected atoms.

AIP conference proceedings•Jan 1, 2004•0 citations

Retrodiction as a tool for micromaser field measurements

John Jeffers, S. M. Barnett, David Thomas Pegg

We use retrodictive quantum theory to describe cavity field measurements by successive atomic detections in the micromaser. We calculate the state of the micromaser cavity field prior to detection of sequences of atoms in either the excited or ground state, for atoms that are initially prepared in the excited state. This provides the POM elements, which describe such sequences of measurements.

arXiv:quant-ph/0207086•Journal of Modern Optics•Apr 1, 2002•6 citations

Decay of number-state superpositions in a micromaser

John J. Slosser, T. A. B. Kennedy, Pierre Meystre

Coherent superpositions of quantum states are very sensitive to coupling to the environment. The fluctuations associated with this coupling tend to wash out quantum phases, so that in practice only quantum mixtures are observed at the macroscopic level. This problem has been the object of recent interest in connection with measurement theory (Schrodinger cat). Theoretical predictions indicate that the decay of quantum coherences in the so-called pointer basis is amplified by a factor proportional to a measure of the distance in Hilbert space between the states. Micromasers offer a possible experimental tool to investigate the decay of such coherences. Theoretical studies of a lossless version of the micromaster have shown the existence of trapping states | n q 〉 of the cavity mode. These number states are such that atoms injected in the upper state into the cavity experience a 2qπ interaction with the field. Cavity states of the form | ψ 〉 = Σ q C q | n q 〉 are easily shown to be dynamic steady states of the system. Number states are not a pointer basis for the micromaser, and our theoretical results will evidence the qualitative difference in the nature of coherence decay between this and previously studied cases. Because the decay times of micromaser cavities are typically of the order of hundreds of milliseconds, our results should be amenable to experimental verification.

Annual Meeting Optical Society of America•Jan 1, 1988•0 citations

Atomic beam correlations and the quantum state of the micromaser

Per Elmfors, Benny E. Lautrup, Bo-Sture Skagerstam

Correlation measurements on the states of two-level atoms having passed through a micromaser at different times can be used to infer properties of the quantum state of the radiation field in the cavity. Long(short) correlation length in time is to some extent associated with super(sub)-Poissonian photon statistics. The correlation length is also an indicator of a phase structure much richer than what is revealed by the usual single-time observables, like the atomic inversion or the Mandel quality factor. In realistic experimental situations the correlations may extend over many times the decay time of the cavity. Our assertions are verified by comparing theoretical calculations with a high-precision Monte-Carlo simulation of the micromaser system.

arXiv:cond-mat/9506058•Physica Scripta•Jun 1, 1997•7 citations

Quantum revivals in micromasers

Ewan M. Wright, P. Meystre

A distinctive signature of the granulated nature of the electromagnetic field is the revivals known to occur in the dynamics of a two-level atom interacting with a single-field mode (Jaynes-Cummings model). The development of high-Q single-mode cavities combined with progress in Rydberg atom spectroscopy has led to a possibility of verifying these predictions. Revival experiments using micromasers have been performed by Walther et al. Here the cavity mode is first allowed to reach a steady state, and then probe atoms are injected into the resonator. By measuring their state as they exit the cavity, one can infer the state of the field. We show that the micromaser experiences Jaynes-Cummingslike revivals when the pump parameter θ is varied. However, in contrast to the conventional Jaynes-Cummings situation, which considers initially coherent fields, the micromaser photon statistics are usually not Poissonian and depend sensitively on θ. The micromaser revivals cannot be explained by a semiclassical theory or linearized quantum fluctuations about the semiclassical solution. Rather, an exact quantum treatment, considering fully the granularity of the cavity mode, is required.

Annual Meeting Optical Society of America•Jan 1, 1988•0 citations

Micromaser with injected atomic phase

Rebecca R. McGowan, William C. Schieve

Both approximate and exact methods exist to determine the density matrix of the field inside an incoherently driven micromaser, but as of yet only a steady-state Fokker-Planck solution has been found for the micromaser with injected atomic phase [Phys. Rev. A 34, 2032 (1986)]. Since Fokker-Planck solutions have been shown not to represent the effect of trapping states on the cavity field adequately, other solutions must be sought. In this paper, we present both a highly accurate approximate analytical solution and a more computationally complex numerical solution based on the exact methods of Lu [Phys. Rev. A 47, 1347 (1993)], both of which demonstrate symmetry breaking in the phase. Since the spectra of the injected phase micromaser will be the same as that of the incoherently pumped case, we present numerical comparisons of our two solutions via the phase variance.

Physical Review A•Sep 1, 1997•11 citations
Injected two-level atoms, prepared and measured in various states, make an effective measurement of the cavity field of a micromaser prior to the injection of the atoms. In contrast to other existing literature on the micromaser, we have used the unconventional retrodictive quantum theory which allows us to calculate, in particular, the phase properties of the field state at an earlier time prior to the interaction with the injected atoms.
Coherent superpositions of quantum states are very sensitive to coupling to the environment. The fluctuations associated with this coupling tend to wash out quantum phases, so that in practice only quantum mixtures are observed at the macroscopic level. This problem has been the object of recent interest in connection with measurement theory (Schrodinger cat). Theoretical predictions indicate that the decay of quantum coherences in the so-called pointer basis is amplified by a factor proportional to a measure of the distance in Hilbert space between the states. Micromasers offer a possible experimental tool to investigate the decay of such coherences. Theoretical studies of a lossless version of the micromaster have shown the existence of trapping states | n q 〉 of the cavity mode. These number states are such that atoms injected in the upper state into the cavity experience a 2qπ interaction with the field. Cavity states of the form | ψ 〉 = Σ q C q | n q 〉 are easily shown to be dynamic steady states of the system. Number states are not a pointer basis for the micromaser, and our theoretical results will evidence the qualitative difference in the nature of coherence decay between this and previously studied cases. Because the decay times of micromaser cavities are typically of the order of hundreds of milliseconds, our results should be amenable to experimental verification.
Correlation measurements on the states of two-level atoms having passed through a micromaser at different times can be used to infer properties of the quantum state of the radiation field in the cavity. Long(short) correlation length in time is to some extent associated with super(sub)-Poissonian photon statistics. The correlation length is also an indicator of a phase structure much richer than what is revealed by the usual single-time observables, like the atomic inversion or the Mandel quality factor. In realistic experimental situations the correlations may extend over many times the decay time of the cavity. Our assertions are verified by comparing theoretical calculations with a high-precision Monte-Carlo simulation of the micromaser system.
A distinctive signature of the granulated nature of the electromagnetic field is the revivals known to occur in the dynamics of a two-level atom interacting with a single-field mode (Jaynes-Cummings model). The development of high-Q single-mode cavities combined with progress in Rydberg atom spectroscopy has led to a possibility of verifying these predictions. Revival experiments using micromasers have been performed by Walther et al. Here the cavity mode is first allowed to reach a steady state, and then probe atoms are injected into the resonator. By measuring their state as they exit the cavity, one can infer the state of the field. We show that the micromaser experiences Jaynes-Cummingslike revivals when the pump parameter θ is varied. However, in contrast to the conventional Jaynes-Cummings situation, which considers initially coherent fields, the micromaser photon statistics are usually not Poissonian and depend sensitively on θ. The micromaser revivals cannot be explained by a semiclassical theory or linearized quantum fluctuations about the semiclassical solution. Rather, an exact quantum treatment, considering fully the granularity of the cavity mode, is required.
Both approximate and exact methods exist to determine the density matrix of the field inside an incoherently driven micromaser, but as of yet only a steady-state Fokker-Planck solution has been found for the micromaser with injected atomic phase [Phys. Rev. A 34, 2032 (1986)]. Since Fokker-Planck solutions have been shown not to represent the effect of trapping states on the cavity field adequately, other solutions must be sought. In this paper, we present both a highly accurate approximate analytical solution and a more computationally complex numerical solution based on the exact methods of Lu [Phys. Rev. A 47, 1347 (1993)], both of which demonstrate symmetry breaking in the phase. Since the spectra of the injected phase micromaser will be the same as that of the incoherently pumped case, we present numerical comparisons of our two solutions via the phase variance.