arXiv:cond-mat/9506058 · Physica Scripta

Atomic beam correlations and the quantum state of the micromaser

Per Elmfors, Benny E. Lautrup, Bo-Sture Skagerstam

Published Jun 1, 1997• 7 citations
arXivHTMLPDF

Abstract

Correlation measurements on the states of two-level atoms having passed through a micromaser at different times can be used to infer properties of the quantum state of the radiation field in the cavity. Long(short) correlation length in time is to some extent associated with super(sub)-Poissonian photon statistics. The correlation length is also an indicator of a phase structure much richer than what is revealed by the usual single-time observables, like the atomic inversion or the Mandel quality factor. In realistic experimental situations the correlations may extend over many times the decay time of the cavity. Our assertions are verified by comparing theoretical calculations with a high-precision Monte-Carlo simulation of the micromaser system.

DOI
10.1088/0031-8949/55/6/013

Related papers

Micromaser with stationary non-Poissonian pumping

Ulrike Herzog

A method is presented for theoretically investigating the properties of a one-atom micromaser with stationary non-Poissonian pumping. The method is based on treating the statistics of the arrival times of the individual pump atoms with the help of the theory of stochastic point processes. Considerable simplification is achieved by assuming the pump statistics to be described by a stationary renewal process. Thus the influence of super- as well as sub-Poissonian pumping with different strengths of correlation between the pump atoms and different correlation decay times may be studied quantitatively. The level-selective statistics of the atoms leaving the cavity is investigated as well as the photon statistics of the cavity field. Moreover, the relation to the other models used in the literature for describing the micromaser pump statistics is discussed. It is found that for sub- (super-)Poissonian pumping, the stationary expectation value of the cavity photon number (which corresponds to its time-averaged value) is larger (smaller) than the conditioned mean photon number that would result from averaging over the number of photons present in the cavity at the time instants immediately before the injection of the individual pump atoms. For Poissonian pumping, both quantities are shown to be equal. The relative standard deviation of the stationary cavity photon number is decreased (increased) for sub- (super-) Poissonian pumping, in comparison to the corresponding values that would result from Poissonian pumping. Moreover, it turns out that for sub- (super-)Poissonian pumping, the normalized coincidence probability density for the detection of the outgoing deexcited atoms is smaller (larger) than the normalized cavity field intensity correlation function at zero time delay. The difference decreases with increasing lifetime of the pump-atom correlations. Finally, the level-selective delayed coincidence probability densities of the outgoing atoms and their waiting-time distributions are found to be affected greatly by the correlation strength as well as the correlation decay time of the incoming pump atoms.

Physical Review A•Jul 1, 1995•21 citations

Dynamics, correlations, and phases of the micromaser

Per Elmfors, Benny E. Lautrup, Bo-Sture Skagerstam

The micromaser possesses a variety of dynamical phase transitions parametrized by the flux of atoms and the time of flight of the atom within the cavity. We discuss how these phases may be revealed to an observer outside the cavity using the long-time correlation length in the atomic beam. Some of the phase transitions are not reflected in the average excitation level of the outgoing atom, which is the commonly used observable. The correlation length is directly related to the leading eigenvalue of the time evolution operator, which we study in order to elucidate the phase structure. We find that as a function of the time of flight the transition from the thermal to the maser phase is characterized by a sharp peak in the correlation length. For longer times of flight there is a transition to a phase where the correlation length grows exponentially with the flux. We present a detailed numerical and analytical treatment of the different phases and discuss the physics behind them. \textcopyright{} 1996 The American Physical Society.

arXiv:atom-ph/9601004•Physical Review A•Dec 1, 1996•15 citations

Entangled Atoms in Micromaser Physics

Berthold‐Georg Englert, Berthold‐Georg Englert, M. Löffler +7 more

A micromaser in standard operation produces entangled two-level atoms. This entanglement can be investigated in the correlations of atoms leaving the micromaser cavity in the upper and lower maser levels. The correlations contribute to the stabilization of the photon number in the cavity and are thus vital for the generation of sub-Poissonian statistics in the maser field. We review how various statistical signatures for this entanglement are calculated in micromaser theory, and report recent measurements that demonstrate the case. Ways are described leading to an optimal entanglement for the atoms in the micromaser.

Fortschritte der Physik•Nov 1, 1998•72 citations

Collective two-atom effects and trapping states in the micromaser

Per Kristian Rekdal, Bo-Sture Skagerstam

We investigate signals of trapping states in the micromaser system in terms of the average number $⟨n⟩$ of cavity photons as well as a suitably defined correlation length of atoms leaving the cavity. In the description of collective two-atom effects we allow the mean number, $ϵ$, of pump atoms inside the cavity during the characteristic atomic cavity transit time to be as large as of order one. The master equation we consider, which describes the micromaser including collective two-atom effects, still exhibits trapping states for $ϵ\ensuremath{\ne}0$, even for a mean number of atoms inside the cavity close to one. We, however, argue more importantly that the trapping states are more pronounced in terms of the correlation length as compared to $⟨n⟩$, i.e., we suggest that trapping states can be more clearly revealed experimentally in terms of the atom correlation length. For axion detection in the micromaser this observable may, therefore, be an essential ingredient.

arXiv:quant-ph/0606233•Physical Review A•Dec 7, 2006•0 citations

Experiments with the One-atom-maser

Linas Urbonas

There are only fistful of systems in physics that can be described by an exact theory from first principles and, at the same time, can be investigated under experimental conditions approaching the idealized theoretical ones. The one-atom-maser or micromaser provides such an example, making a detailed study of the fundamental properties of the atom-field interaction possible. The situation realized in a micromaser is very close to the ideal case of a single two-level atom interacting with a single quantized mode of a cavity field. In the micromaser the atoms have a dual purpose of both pumping the field and also probing it via measurements of the outgoing atoms. Any other means of measuring the field inside the resonator has the detrimental effect of lowering its Q-factor and thereby the photon storage time. The long photon storage time of the resonator allows for the decay of the field to be negligible during the passage of an atom and its interaction with the field. The behavior of atoms in a cavity is governed by the oscillatory exchange of energy between the atoms and the field, which is called Rabi oscillation. For cavity fields in the vacuum and few photon number states (Fock states), Rabi oscillations have been measured in the past. To prevent thermal effects from polluting the pure number states these experiments were performed at low temperatures (below 1 K). However, the observed resolution of the Rabi oscillations measurements was quite disappointing (only about 2% of the predicted theoretical value) and precluded more ambitious experiments like atom-atom correlations or time resolved investigations of the maser field dynamics. The observed contrast of Rabi oscillations can be considered as a figure of merit for the experimental resolution of quantum features of a maser field. Therefore, a high resolution in the measurements of Rabi oscillations is crucial. This thesis describes the methods and improvements applied to enhance the resolution of Rabi oscillations by a factor of 8. The following upgrades and developments proved to be crucial in this work: 1) The base temperature of the cryogenic system was lowered to 0.3 K, i.e. one third of the original value. At the same time, the time during which the system remains at the base temperature was improved by almost of an order of magnitude (to more than 12 h). 2) For the promotion of the atoms to the Rydberg regime new three-step diode laser setup was constructed. The excitation efficiency compared to the old dye laser was increased by two orders. Using top-of-fringe stabilization with new spectroscopic methods, specially designed error detection and feedback schemes as well as state-of-the-art PID regulators the continuous locking of lasers is about 8 h (compared to about 20 min with the old dye laser system). 3) The flexibility of using the three step excitation allows to excite different maser states and for the first time to investigate pure maser transition. 4) Various improvements on the atomic oven and the channeltron detection unit led to the reliable and stable production and detection of the atomic beam. Observed distribution of the atomic beam statistics reaches to within 6% the Poisson limit which is expected in the absence of experimental imperfections. 5) New developed techniques in magnetic field compensation allow to perform such measurements with two orders of magnitude better accuracy compared to the previous experiments. To demonstrate the new capabilities of the apparatus and to apply its improved resolution of quantum fields we performed a previously impossible in-depth analysis of mean photon number and the atomic inversion produced by a micromaser for various detunings between the cavity- and atomic resonance frequency.

•Jan 1, 2009•0 citations

Quantum revivals in micromasers

Ewan M. Wright, P. Meystre

A distinctive signature of the granulated nature of the electromagnetic field is the revivals known to occur in the dynamics of a two-level atom interacting with a single-field mode (Jaynes-Cummings model). The development of high-Q single-mode cavities combined with progress in Rydberg atom spectroscopy has led to a possibility of verifying these predictions. Revival experiments using micromasers have been performed by Walther et al. Here the cavity mode is first allowed to reach a steady state, and then probe atoms are injected into the resonator. By measuring their state as they exit the cavity, one can infer the state of the field. We show that the micromaser experiences Jaynes-Cummingslike revivals when the pump parameter θ is varied. However, in contrast to the conventional Jaynes-Cummings situation, which considers initially coherent fields, the micromaser photon statistics are usually not Poissonian and depend sensitively on θ. The micromaser revivals cannot be explained by a semiclassical theory or linearized quantum fluctuations about the semiclassical solution. Rather, an exact quantum treatment, considering fully the granularity of the cavity mode, is required.

Annual Meeting Optical Society of America•Jan 1, 1988•0 citations
Correlation measurements on the states of two-level atoms having passed through a micromaser at different times can be used to infer properties of the quantum state of the radiation field in the cavity. Long(short) correlation length in time is to some extent associated with super(sub)-Poissonian photon statistics. The correlation length is also an indicator of a phase structure much richer than what is revealed by the usual single-time observables, like the atomic inversion or the Mandel quality factor. In realistic experimental situations the correlations may extend over many times the decay time of the cavity. Our assertions are verified by comparing theoretical calculations with a high-precision Monte-Carlo simulation of the micromaser system.
A method is presented for theoretically investigating the properties of a one-atom micromaser with stationary non-Poissonian pumping. The method is based on treating the statistics of the arrival times of the individual pump atoms with the help of the theory of stochastic point processes. Considerable simplification is achieved by assuming the pump statistics to be described by a stationary renewal process. Thus the influence of super- as well as sub-Poissonian pumping with different strengths of correlation between the pump atoms and different correlation decay times may be studied quantitatively. The level-selective statistics of the atoms leaving the cavity is investigated as well as the photon statistics of the cavity field. Moreover, the relation to the other models used in the literature for describing the micromaser pump statistics is discussed. It is found that for sub- (super-)Poissonian pumping, the stationary expectation value of the cavity photon number (which corresponds to its time-averaged value) is larger (smaller) than the conditioned mean photon number that would result from averaging over the number of photons present in the cavity at the time instants immediately before the injection of the individual pump atoms. For Poissonian pumping, both quantities are shown to be equal. The relative standard deviation of the stationary cavity photon number is decreased (increased) for sub- (super-) Poissonian pumping, in comparison to the corresponding values that would result from Poissonian pumping. Moreover, it turns out that for sub- (super-)Poissonian pumping, the normalized coincidence probability density for the detection of the outgoing deexcited atoms is smaller (larger) than the normalized cavity field intensity correlation function at zero time delay. The difference decreases with increasing lifetime of the pump-atom correlations. Finally, the level-selective delayed coincidence probability densities of the outgoing atoms and their waiting-time distributions are found to be affected greatly by the correlation strength as well as the correlation decay time of the incoming pump atoms.
The micromaser possesses a variety of dynamical phase transitions parametrized by the flux of atoms and the time of flight of the atom within the cavity. We discuss how these phases may be revealed to an observer outside the cavity using the long-time correlation length in the atomic beam. Some of the phase transitions are not reflected in the average excitation level of the outgoing atom, which is the commonly used observable. The correlation length is directly related to the leading eigenvalue of the time evolution operator, which we study in order to elucidate the phase structure. We find that as a function of the time of flight the transition from the thermal to the maser phase is characterized by a sharp peak in the correlation length. For longer times of flight there is a transition to a phase where the correlation length grows exponentially with the flux. We present a detailed numerical and analytical treatment of the different phases and discuss the physics behind them. \textcopyright{} 1996 The American Physical Society.
A micromaser in standard operation produces entangled two-level atoms. This entanglement can be investigated in the correlations of atoms leaving the micromaser cavity in the upper and lower maser levels. The correlations contribute to the stabilization of the photon number in the cavity and are thus vital for the generation of sub-Poissonian statistics in the maser field. We review how various statistical signatures for this entanglement are calculated in micromaser theory, and report recent measurements that demonstrate the case. Ways are described leading to an optimal entanglement for the atoms in the micromaser.
We investigate signals of trapping states in the micromaser system in terms of the average number ⟨n⟩⟨n⟩⟨n⟩ of cavity photons as well as a suitably defined correlation length of atoms leaving the cavity. In the description of collective two-atom effects we allow the mean number, ϵϵϵ, of pump atoms inside the cavity during the characteristic atomic cavity transit time to be as large as of order one. The master equation we consider, which describes the micromaser including collective two-atom effects, still exhibits trapping states for $ϵ\ensuremath{\ne}0$, even for a mean number of atoms inside the cavity close to one. We, however, argue more importantly that the trapping states are more pronounced in terms of the correlation length as compared to ⟨n⟩⟨n⟩⟨n⟩, i.e., we suggest that trapping states can be more clearly revealed experimentally in terms of the atom correlation length. For axion detection in the micromaser this observable may, therefore, be an essential ingredient.
There are only fistful of systems in physics that can be described by an exact theory from first principles and, at the same time, can be investigated under experimental conditions approaching the idealized theoretical ones. The one-atom-maser or micromaser provides such an example, making a detailed study of the fundamental properties of the atom-field interaction possible. The situation realized in a micromaser is very close to the ideal case of a single two-level atom interacting with a single quantized mode of a cavity field. In the micromaser the atoms have a dual purpose of both pumping the field and also probing it via measurements of the outgoing atoms. Any other means of measuring the field inside the resonator has the detrimental effect of lowering its Q-factor and thereby the photon storage time. The long photon storage time of the resonator allows for the decay of the field to be negligible during the passage of an atom and its interaction with the field. The behavior of atoms in a cavity is governed by the oscillatory exchange of energy between the atoms and the field, which is called Rabi oscillation. For cavity fields in the vacuum and few photon number states (Fock states), Rabi oscillations have been measured in the past. To prevent thermal effects from polluting the pure number states these experiments were performed at low temperatures (below 1 K). However, the observed resolution of the Rabi oscillations measurements was quite disappointing (only about 2% of the predicted theoretical value) and precluded more ambitious experiments like atom-atom correlations or time resolved investigations of the maser field dynamics. The observed contrast of Rabi oscillations can be considered as a figure of merit for the experimental resolution of quantum features of a maser field. Therefore, a high resolution in the measurements of Rabi oscillations is crucial. This thesis describes the methods and improvements applied to enhance the resolution of Rabi oscillations by a factor of 8. The following upgrades and developments proved to be crucial in this work: 1) The base temperature of the cryogenic system was lowered to 0.3 K, i.e. one third of the original value. At the same time, the time during which the system remains at the base temperature was improved by almost of an order of magnitude (to more than 12 h). 2) For the promotion of the atoms to the Rydberg regime new three-step diode laser setup was constructed. The excitation efficiency compared to the old dye laser was increased by two orders. Using top-of-fringe stabilization with new spectroscopic methods, specially designed error detection and feedback schemes as well as state-of-the-art PID regulators the continuous locking of lasers is about 8 h (compared to about 20 min with the old dye laser system). 3) The flexibility of using the three step excitation allows to excite different maser states and for the first time to investigate pure maser transition. 4) Various improvements on the atomic oven and the channeltron detection unit led to the reliable and stable production and detection of the atomic beam. Observed distribution of the atomic beam statistics reaches to within 6% the Poisson limit which is expected in the absence of experimental imperfections. 5) New developed techniques in magnetic field compensation allow to perform such measurements with two orders of magnitude better accuracy compared to the previous experiments. To demonstrate the new capabilities of the apparatus and to apply its improved resolution of quantum fields we performed a previously impossible in-depth analysis of mean photon number and the atomic inversion produced by a micromaser for various detunings between the cavity- and atomic resonance frequency.
A distinctive signature of the granulated nature of the electromagnetic field is the revivals known to occur in the dynamics of a two-level atom interacting with a single-field mode (Jaynes-Cummings model). The development of high-Q single-mode cavities combined with progress in Rydberg atom spectroscopy has led to a possibility of verifying these predictions. Revival experiments using micromasers have been performed by Walther et al. Here the cavity mode is first allowed to reach a steady state, and then probe atoms are injected into the resonator. By measuring their state as they exit the cavity, one can infer the state of the field. We show that the micromaser experiences Jaynes-Cummingslike revivals when the pump parameter θ is varied. However, in contrast to the conventional Jaynes-Cummings situation, which considers initially coherent fields, the micromaser photon statistics are usually not Poissonian and depend sensitively on θ. The micromaser revivals cannot be explained by a semiclassical theory or linearized quantum fluctuations about the semiclassical solution. Rather, an exact quantum treatment, considering fully the granularity of the cavity mode, is required.