Ultracold metastable calcium atoms in a bichromatic magneto-optical trap

Jan Grünert

Published Jan 1, 2002• 1 citation
OpenAlex

Related papers

Optimizing the production of metastable calcium atoms in a magneto-optical trap

Jan Grünert, Andreas Hemmerich

arXiv:physics/0107034•Applied Physics B•Dec 1, 2001•29 citations

ULTRACOLD METASTABLE CALCIUM ATOMS

Jan Grünert, Andreas Hemmerich

We explore an efficient method for preparing large samples of ultracold calcium atoms. An optimized conventional (Doppler-limited) magneto–optical trap collects atoms from a Zeeman cooled atomic beam using a strong dipole transition within the singlet system. This transition is not completely closed thus yielding an intense flux of atoms into the metastable triplet state 3 P 2 . We obtain a flux of above 10 10 atoms/s into the 3 P 2 state. We find that our MOT life time of 23 ms is mainly limited by this loss channel and thus the 3 P 2 production is not hampered by inelasic collisions. A second magneto–optical trap sharing the same magnetic field gradient is superimposed which captures and further cools the metastables using the narrow–band infrared transition 3 P 2 → 3 D 3 . In our present experiment we were able to prepare 3 × 10 8 atoms at temperatures below 20 microkelvin within 250 ms. Minor technical improvements of our setup promise to yield above 10 10 atoms at sub–microkelvin temperatures within 1 s.

Symposium on Frequency Standards and Metrology•May 1, 2002•1 citation

ULTRACOLD CALCIUM ATOMS FOR OPTICAL CLOCKS AND COLLISIONAL STUDIES

Uwe Sterr, C. Degenhardt, Hardo Stoehr +6 more

Laser Spectroscopy•Feb 1, 2004•1 citation

Sub-Doppler magneto-optical trap for calcium

Jan Grünert, Andreas Hemmerich

We explore an efficient method for preparing large samples of ultracold calcium atoms. An optimized conventional (Doppler-limited) magneto-optical trap collects atoms from a Zeeman cooled atomic beam using a strong dipole transition within the singlet system. This transition is not completely closed thus yielding an intense flux of atoms into the metastable triplet state ${}^{3}{P}_{2}.$ A second magneto-optical trap sharing the same magnetic-field gradient is superimposed which captures and further cools the metastables using the narrow-band infrared transition ${}^{3}{\stackrel{\ensuremath{\rightarrow}}{{P}_{2}}}^{3}{D}_{3}.$ In our present experiment we were able to prepare $3\ifmmode\times\else\texttimes\fi{}{10}^{8}$ atoms at temperatures below 20 microkelvin within 250 ms. Minor technical improvements of our setup promise to yield above ${10}^{10}$ atoms at submicrokelvin temperatures within 1 s.

Physical Review A•Mar 29, 2002•71 citations

Magneto-optical trap of metastable helium-3 atoms

M. Kumakura, N. Morita

Applied Physics B•Apr 1, 2000•2 citations

Magnetic trapping of metastable calcium atoms

Dirk P. Hansen, Janis R. Mohr, Andreas Hemmerich

Metastable calcium atoms, produced in a magneto-optic trap (MOT) operating within the singlet system, are continuously loaded into a magnetic trap formed by the magnetic quadrupole field of the MOT. At MOT temperatures of 3 mK and 240 ms loading time, we observe $1.1\ifmmode\times\else\texttimes\fi{}{10}^{8}$ magnetically trapped ${}^{3}{P}_{2}$ atoms at densities of $2.4\ifmmode\times\else\texttimes\fi{}{10}^{8}{\mathrm{cm}}^{\ensuremath{-}3}$ and temperatures of 0.61 mK. In a modified scheme, we first load a MOT for metastable atoms at a temperature of 0.18 mK and subsequently release these atoms into the magnetic trap. In this case, 240 ms of loading yields $2.4\ifmmode\times\else\texttimes\fi{}{10}^{8}$ trapped ${}^{3}{P}_{2}$ atoms at a peak density of $8.7\ifmmode\times\else\texttimes\fi{}{10}^{10}{\mathrm{cm}}^{\ensuremath{-}3}$ and a temperature of 0.13 mK. The temperature decrease observed in the magnetic trap for both loading schemes can be explained only in part by trap size effects.

arXiv:physics/0210119•Physical Review A•Feb 28, 2003•30 citations
We explore an efficient method for preparing large samples of ultracold calcium atoms. An optimized conventional (Doppler-limited) magneto–optical trap collects atoms from a Zeeman cooled atomic beam using a strong dipole transition within the singlet system. This transition is not completely closed thus yielding an intense flux of atoms into the metastable triplet state 3 P 2 . We obtain a flux of above 10 10 atoms/s into the 3 P 2 state. We find that our MOT life time of 23 ms is mainly limited by this loss channel and thus the 3 P 2 production is not hampered by inelasic collisions. A second magneto–optical trap sharing the same magnetic field gradient is superimposed which captures and further cools the metastables using the narrow–band infrared transition 3 P 2 → 3 D 3 . In our present experiment we were able to prepare 3 × 10 8 atoms at temperatures below 20 microkelvin within 250 ms. Minor technical improvements of our setup promise to yield above 10 10 atoms at sub–microkelvin temperatures within 1 s.
We explore an efficient method for preparing large samples of ultracold calcium atoms. An optimized conventional (Doppler-limited) magneto-optical trap collects atoms from a Zeeman cooled atomic beam using a strong dipole transition within the singlet system. This transition is not completely closed thus yielding an intense flux of atoms into the metastable triplet state 3P2.{}^{3}{P}_{2}.3P2​. A second magneto-optical trap sharing the same magnetic-field gradient is superimposed which captures and further cools the metastables using the narrow-band infrared transition ${}^{3}{\stackrel{\ensuremath{\rightarrow}}{{P}_{2}}}^{3}{D}_{3}.$ In our present experiment we were able to prepare $3\ifmmode\times\else\texttimes\fi{}{10}^{8}$ atoms at temperatures below 20 microkelvin within 250 ms. Minor technical improvements of our setup promise to yield above 1010{10}^{10}1010 atoms at submicrokelvin temperatures within 1 s.
Metastable calcium atoms, produced in a magneto-optic trap (MOT) operating within the singlet system, are continuously loaded into a magnetic trap formed by the magnetic quadrupole field of the MOT. At MOT temperatures of 3 mK and 240 ms loading time, we observe $1.1\ifmmode\times\else\texttimes\fi{}{10}^{8}$ magnetically trapped 3P2{}^{3}{P}_{2}3P2​ atoms at densities of $2.4\ifmmode\times\else\texttimes\fi{}{10}^{8}{\mathrm{cm}}^{\ensuremath{-}3}$ and temperatures of 0.61 mK. In a modified scheme, we first load a MOT for metastable atoms at a temperature of 0.18 mK and subsequently release these atoms into the magnetic trap. In this case, 240 ms of loading yields $2.4\ifmmode\times\else\texttimes\fi{}{10}^{8}$ trapped 3P2{}^{3}{P}_{2}3P2​ atoms at a peak density of $8.7\ifmmode\times\else\texttimes\fi{}{10}^{10}{\mathrm{cm}}^{\ensuremath{-}3}$ and a temperature of 0.13 mK. The temperature decrease observed in the magnetic trap for both loading schemes can be explained only in part by trap size effects.