Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Buffer gas cooled atoms and molecules: Production, collisional studies, and applications

Stephen Maxwell

Published Jan 1, 2007• 1 citation
OpenAlex

Related papers

Toward Ultracold Atomic Hydrogen and Deuterium: An Application of Buffer Gas Cooling

Bonna K. Newman, Cort Johnson, Nathan Brahms +5 more

Bulletin of the American Physical Society•May 19, 2006•0 citations

A permanent magnet trap for buffer gas cooled atoms and molecules

Didier Nohlmans, Sarah M. Skoff, Richard Hendricks +4 more

Bulletin of the American Physical Society•Jun 6, 2013•0 citations

Rotational relaxation of fluoromethane molecules in low-temperature collisions with buffer-gas helium

Xingjia Li, Liang Xu, Yanning Yin +3 more

We propose a method to study the rotational relaxation of polar molecules [here taking fluoromethane $({\mathrm{CH}}_{3}\mathrm{F})$ as an example] in collisions with 3.5 K buffer-gas helium (He) atoms by using an electrostatic guiding technique. The dependence of the guiding signal of ${\mathrm{CH}}_{3}\mathrm{F}$ on the injected He flux and the dependence of the guiding efficiency of ${\mathrm{CH}}_{3}\mathrm{F}$ on its rotational temperature are investigated both theoretically and experimentally. By comparing the experimental and simulated results, we find that the translational and rotational temperatures of the buffer-gas cooled ${\mathrm{CH}}_{3}\mathrm{F}$ molecules can reach to about 5.48 and 0.60 K, respectively, and the ratio between the translational and average rotational collisional cross sections of ${\mathrm{CH}}_{3}\mathrm{F}\ensuremath{-}\mathrm{He}$ is $\ensuremath{\gamma}={\ensuremath{\sigma}}_{t}/{\ensuremath{\sigma}}_{r}=36.49\ifmmode\pm\else\textpm\fi{}6.15$. In addition, the slowing, cooling, and boosting effects of the molecular beam with different injected He fluxes are also observed and their forming conditions are investigated in some detail. Our study shows that our proposed method can not only be used to measure the translational and rotational temperatures of the buffer-gas cooled molecules, but also to measure the ratio of the translational collisional cross section to the average rotational collisional cross section, and even to measure the average rotational collisional cross section when the translational collisional cross section is measured by fitting the lifetime of molecule signal to get a numerical solution from the diffusion equation of buffer-gas He atoms in the cell.

Physical Review A•Jun 6, 2016•9 citations

Buffer gas cooled beams and cold molecular collisions

David Patterson

•Jan 1, 2010•3 citations

Realization of coherent optically dense media via buffer-gas cooling

Tao Hong, Alexey Vyacheslavovich Gorshkov, David Patterson +4 more

We demonstrate that buffer-gas cooling combined with laser ablation can be used to create coherent optical media with high optical depth and low Doppler broadening that offers metastable states with low collisional and motional decoherence. Demonstration of this generic technique opens pathways to coherent optics with a large variety of atoms and molecules. We use helium buffer gas to cool $^{87}\mathrm{Rb}$ atoms to below $7\phantom{\rule{0.3em}{0ex}}\mathrm{K}$ and slow atom diffusion to the walls. Electromagnetically induced transparency in this medium allows for 50% transmission in a medium with initial optical depth $D>70$ and for slow pulse propagation with large delay-bandwidth products. In the high-$D$ regime, we observe high-contrast spectrum oscillations due to efficient four-wave mixing.

arXiv:0805.1416•Physical Review A•Jan 6, 2009•24 citations

Buffer-gas cooling of diatomic molecules

Dimitri Michael Egorov

•Jan 1, 2004•6 citations
We propose a method to study the rotational relaxation of polar molecules [here taking fluoromethane (CH3F)({\mathrm{CH}}_{3}\mathrm{F})(CH3​F) as an example] in collisions with 3.5 K buffer-gas helium (He) atoms by using an electrostatic guiding technique. The dependence of the guiding signal of CH3F{\mathrm{CH}}_{3}\mathrm{F}CH3​F on the injected He flux and the dependence of the guiding efficiency of CH3F{\mathrm{CH}}_{3}\mathrm{F}CH3​F on its rotational temperature are investigated both theoretically and experimentally. By comparing the experimental and simulated results, we find that the translational and rotational temperatures of the buffer-gas cooled CH3F{\mathrm{CH}}_{3}\mathrm{F}CH3​F molecules can reach to about 5.48 and 0.60 K, respectively, and the ratio between the translational and average rotational collisional cross sections of ${\mathrm{CH}}_{3}\mathrm{F}\ensuremath{-}\mathrm{He}$ is $\ensuremath{\gamma}={\ensuremath{\sigma}}_{t}/{\ensuremath{\sigma}}_{r}=36.49\ifmmode\pm\else\textpm\fi{}6.15$. In addition, the slowing, cooling, and boosting effects of the molecular beam with different injected He fluxes are also observed and their forming conditions are investigated in some detail. Our study shows that our proposed method can not only be used to measure the translational and rotational temperatures of the buffer-gas cooled molecules, but also to measure the ratio of the translational collisional cross section to the average rotational collisional cross section, and even to measure the average rotational collisional cross section when the translational collisional cross section is measured by fitting the lifetime of molecule signal to get a numerical solution from the diffusion equation of buffer-gas He atoms in the cell.
We demonstrate that buffer-gas cooling combined with laser ablation can be used to create coherent optical media with high optical depth and low Doppler broadening that offers metastable states with low collisional and motional decoherence. Demonstration of this generic technique opens pathways to coherent optics with a large variety of atoms and molecules. We use helium buffer gas to cool 87Rb^{87}\mathrm{Rb}87Rb atoms to below 7K7\phantom{\rule{0.3em}{0ex}}\mathrm{K}7K and slow atom diffusion to the walls. Electromagnetically induced transparency in this medium allows for 50% transmission in a medium with initial optical depth D>70D>70D>70 and for slow pulse propagation with large delay-bandwidth products. In the high-DDD regime, we observe high-contrast spectrum oscillations due to efficient four-wave mixing.