Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

How could the detection of an interference pattern be affected by photons which do not enter the interferometer

А. В. Белинский

Published Jul 1, 1991• 8 citations
OpenAlex

Related papers

How can photons that do not enter into the interferometer influence the recording of the interference pattern

А. В. Белинский

Письма в Журнал экспериментальной и теоретической физики•Jul 1, 1991•0 citations

THE INTERFERENCE PHENOMENA OF LIGHT AT VERY LOW INTENSITY

Z Janossy

An interference pattern is obtained with a Michelson interferometer; the intensity distribution in the pattern is determined by counting the rate of photons by means of a photomultiplier. It is shown that the pattern obtained for very low intensities of light does not differ outside the margin of experimental error from the pattern obtained for normal intensities. At low intensities about 10 photons enter the interferometer per second thus for these low intensities in average at any time much less than one photon is contained inside the interferometer.

Acta Physica Sinica•Jan 1, 1958•0 citations

How to detect photons passing through interference minima

Luis Grave de Peralta, Daniel Domı́nguez

Bulletin of the American Physical Society•Oct 26, 2012•0 citations

THE INTERFERENCE PHENOMENA OF LIGHT AT VERY LOW INTENSITY

Lajos Jánossy, Zs. Náray, 匈牙利科学院中央物理研究所

An interference pattern is obtained with a Michelson interferometer; the intensity distribution in the pattern is determined by counting the rate of photons by means of a photomultiplier. It is shown that the pattern obtained for very low intensities of light does not differ outside the margin of experimental error from the pattern obtained for normal intensities. At low intensities about 106 photons enter the interferometer per second thus for these low intensities in average at any time much less than one photon is contained inside the interferometer.

Acta Physica Sinica•Jan 1, 1958•0 citations

Multi-photon interference and quantum optical interferometry

Richard J. Birrittella, Jihane Mimih, Christopher C. Gerry

APS•May 1, 2013•0 citations

Enhanced Readout from Spatial Interference Fringes in a Point-Source Cold Atom Inertial Sensor

Jing Wang, Junze Tong, Wenbin Xie +3 more

When the initial size of an atom cloud in a cold atom interferometer is negligible compared to its size after free expansion, the interferometer is approximated to a point-source interferometer and is sensitive to rotational movements by introducing an additional phase shear in the interference sequence. This sensitivity on rotation enables a vertical atom-fountain interferometer to measure angular velocity in addition to gravitational acceleration, which it is conventionally used to measure. The accuracy and precision of the angular velocity measurement depends on proper extraction of frequency and phase from spatial interference patterns detected via the imaging of the atom cloud, which is usually affected by various systematic biases and noise. To improve the measurement, a pre-fitting process based on principal component analysis is applied to the recorded raw images. The contrast of interference patterns are enhanced by 7-12 dB when the processing is present, which leads to an enhancement in the precision of angular velocity measurements from 6.3 μrad/s to 3.3 μrad/s. This technique is applicable in various instruments that involve precise extraction of frequency and phase from a spatial interference pattern.

Sensors•May 25, 2023•3 citations
An interference pattern is obtained with a Michelson interferometer; the intensity distribution in the pattern is determined by counting the rate of photons by means of a photomultiplier. It is shown that the pattern obtained for very low intensities of light does not differ outside the margin of experimental error from the pattern obtained for normal intensities. At low intensities about 10 photons enter the interferometer per second thus for these low intensities in average at any time much less than one photon is contained inside the interferometer.
An interference pattern is obtained with a Michelson interferometer; the intensity distribution in the pattern is determined by counting the rate of photons by means of a photomultiplier. It is shown that the pattern obtained for very low intensities of light does not differ outside the margin of experimental error from the pattern obtained for normal intensities. At low intensities about 106 photons enter the interferometer per second thus for these low intensities in average at any time much less than one photon is contained inside the interferometer.
When the initial size of an atom cloud in a cold atom interferometer is negligible compared to its size after free expansion, the interferometer is approximated to a point-source interferometer and is sensitive to rotational movements by introducing an additional phase shear in the interference sequence. This sensitivity on rotation enables a vertical atom-fountain interferometer to measure angular velocity in addition to gravitational acceleration, which it is conventionally used to measure. The accuracy and precision of the angular velocity measurement depends on proper extraction of frequency and phase from spatial interference patterns detected via the imaging of the atom cloud, which is usually affected by various systematic biases and noise. To improve the measurement, a pre-fitting process based on principal component analysis is applied to the recorded raw images. The contrast of interference patterns are enhanced by 7-12 dB when the processing is present, which leads to an enhancement in the precision of angular velocity measurements from 6.3 μrad/s to 3.3 μrad/s. This technique is applicable in various instruments that involve precise extraction of frequency and phase from a spatial interference pattern.