Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

電子情報通信学会技術研究報告. SCE, 超伝導エレクトロニクス

Proposal of Measurement Method of Extremely Small Power Dissipation Using a Superconducting Resonator

尚輝 竹内, 裕希 山梨, 信行 吉川

Published Apr 13, 2012• 0 citations
OpenAlex

Related papers

Negative-Inductance Superconducting Quantum Interference Device With Energy Dissipation of 1.38 zJ/bit Measured by Inductively Coupled Coplanar Waveguide Resonator

Hao Li, Jianshe Liu, Han Cai +4 more

High energy-efficient superconducting circuits are increasingly desirable for information technology. Negative-inductance superconducting quantum interference device (nSQUID) is considered to have the capability of approaching the physical limit of irreversible computing. Superconducting coplanar waveguide (CPW) resonator of high quality factor Q is widely used for detecting extremely small signals. To measure the energy dissipation in nSQUID, we have designed and fabricated an nSQUID with its common mode flux control inductively coupled to a superconducting CPW resonator. The energy dissipation can be obtained from the changes in transmission spectra of the coupled circuit at different input powers. Low temperature experimental results at 1.07 K show that the bit operation energy in nSQUID operating at 2.19 GHz is about 1.38 zJ.

IEEE Transactions on Applied Superconductivity•Dec 20, 2016•1 citation

Efficient Measurement of Superconducting Resonators

S. Sendelbach, M. J. A. Stoutimore, Josh Strong +3 more

Bulletin of the American Physical Society•Mar 5, 2014•0 citations

Probing dissipation from vortices with superconducting microwave resonators.

Chengkun Song, Tom Heitmann, M. P. DeFeo +3 more

Bulletin of the American Physical Society•Mar 11, 2008•0 citations

Measurement of 10 zJ energy dissipation of adiabatic quantum-flux-parametron logic using a superconducting resonator

Naoki Takeuchi, Yuki Yamanashi, Nobuyuki Yoshikawa

Adiabatic quantum-flux-parametron (AQFP) logic has the potential to operate with an ultimately small bit energy of several zeptojoules; however, this is too small to measure by conventional techniques. We measure such a small energy dissipation by coupling a superconducting resonator with an AQFP gate, where the insertion loss is sensitively varied with the small dissipation due to the very high Q factor of the resonator. We designed and implemented a 5 GHz superconducting resonator coupled with an AQFP gate. Measurement results show that the bit energy of the gate is ∼10 zJ at 5 GHz operation.

Applied Physics Letters•Feb 4, 2013•84 citations

A method for determining dissipative effects in superconductive devices

Anedio Ranfagni, Daniela Mugnai

Physics Letters A•Oct 22, 2014•2 citations

Efficient methods for extracting superconducting resonator loss in the single-photon regime

Cliff Chen, David Perello, Shahriar Aghaeimeibodi +6 more

Superconducting micro-resonators have application in sensors and quantum computing. Measurement of the resonator internal loss in the single-photon regime is a common tool to study the origins of dissipation, noise, and decoherence in quantum circuits, as well as characterization of materials used for quantum devices. However, such measurements are challenging and time-consuming with large uncertainties due to the poor signal-to-noise ratio when measured at single-photon power levels. We developed methods to extract a subset of the resonator fitting parameters at high power and fix them in the analysis of low power data, which reduce the parameter space in the regression analysis. By comparing the analysis with and without partial extraction, we show that these methods reduce the uncertainty of the results, while improving the robustness and efficiency of the loss measurement.

Journal of Applied Physics•Jan 28, 2025•4 citations
High energy-efficient superconducting circuits are increasingly desirable for information technology. Negative-inductance superconducting quantum interference device (nSQUID) is considered to have the capability of approaching the physical limit of irreversible computing. Superconducting coplanar waveguide (CPW) resonator of high quality factor Q is widely used for detecting extremely small signals. To measure the energy dissipation in nSQUID, we have designed and fabricated an nSQUID with its common mode flux control inductively coupled to a superconducting CPW resonator. The energy dissipation can be obtained from the changes in transmission spectra of the coupled circuit at different input powers. Low temperature experimental results at 1.07 K show that the bit operation energy in nSQUID operating at 2.19 GHz is about 1.38 zJ.
Adiabatic quantum-flux-parametron (AQFP) logic has the potential to operate with an ultimately small bit energy of several zeptojoules; however, this is too small to measure by conventional techniques. We measure such a small energy dissipation by coupling a superconducting resonator with an AQFP gate, where the insertion loss is sensitively varied with the small dissipation due to the very high Q factor of the resonator. We designed and implemented a 5 GHz superconducting resonator coupled with an AQFP gate. Measurement results show that the bit energy of the gate is ∼10 zJ at 5 GHz operation.
Superconducting micro-resonators have application in sensors and quantum computing. Measurement of the resonator internal loss in the single-photon regime is a common tool to study the origins of dissipation, noise, and decoherence in quantum circuits, as well as characterization of materials used for quantum devices. However, such measurements are challenging and time-consuming with large uncertainties due to the poor signal-to-noise ratio when measured at single-photon power levels. We developed methods to extract a subset of the resonator fitting parameters at high power and fix them in the analysis of low power data, which reduce the parameter space in the regression analysis. By comparing the analysis with and without partial extraction, we show that these methods reduce the uncertainty of the results, while improving the robustness and efficiency of the loss measurement.