arXiv:2611.02418
Nearly Transform-Limited Pulse-Like Temporal and Narrowband Spectral Responses in Sum-Frequency Generation from Bright Twin Beams
Yujiro Eto
Abstract
We simultaneously characterize the temporal and spectral responses of the coherent component in bright twin beams using a spectrally resolved, delay-dependent sum-frequency generation (SFG) measurement. The measured temporal-correlation width is 0.138 ps, close to the transform-limited value of 0.126 ps estimated from the measured twin-beam spectrum.The observed spectral-correlation width is 0.176 rad/ps and is limited by the spectrometer resolution. The corresponding time-frequency width product is 0.0243, far below the value of 1 for SFG between two independent transform-limited Gaussian pulses.
AI Summary
The paper asks whether bright twin beams can simultaneously provide a nearly transform-limited temporal response and narrow spectral selectivity in the same coherent two-photon signal. It uses spectrally resolved, delay-dependent sum-frequency generation (SFG) to characterize these responses in high-gain parametric down-conversion. The twin beams are spatially filtered toward a fundamental Gaussian mode, yielding 0.67 mW total average power, and recombined in a $100\,\mu\mathrm{m}$ BBO crystal with variable relative delay. The measured SFG spectra contain a narrow coherent peak associated with frequency-correlated signal–idler modes and a broadband incoherent background. Gaussian fits give a temporal standard deviation of $\sigma_{\tau_-}=0.138\,\mathrm{ps}$ and a spectral standard deviation of $\sigma_{\omega_+}=0.176\,\mathrm{rad/ps}$. Fourier transforming the measured signal spectrum with spectral phase set to zero predicts a transform-limited temporal width of $0.126\,\mathrm{ps}$, approximately 10% below the measured width. Both correlation widths are extracted from the same delay–frequency dataset. Their product is $\sigma_{\tau_-}\sigma_{\omega_+}=0.0243$, compared with unity for SFG between independent, identical transform-limited Gaussian pulses under the stated width convention. The spectral width is limited by spectrometer resolution. The reported product characterizes the coherent component with the incoherent background excluded, rather than the complete SFG signal. Consequently, the proposed use for high-flux, sub-Fourier time–frequency spectroscopy remains conditional on suppressing or removing that background; no spectroscopic application is demonstrated.
Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.
- Comments
- 4 pages