We report on the observation of broadband (40 THz) bright twin beams through high-gain parametric downconversion in an aperiodically poled lithium niobate crystal. The output photon number is shown to scale exponentially with the pump power and not with the pump amplitude, as in homogeneous crystals. Photon number correlations and the number of frequency/temporal modes are assessed by spectral covariance measurements. By using sum-frequency generation on the surface of a non-phase-matched crystal, we measure a cross-correlation peak with the temporal width of 90 fs.
We report on the observation of broadband (40 THz) bright twin beams through high-gain parametric downconversion in an aperiodically poled lithium niobate crystal. The output photon number is shown to scale exponentially with the pump power and not with the pump amplitude, as in homogeneous crystals. Photon number correlations and the number of frequency/temporal modes are assessed by spectral covariance measurements. By using sum-frequency generation on the surface of a non-phase-matched crystal, we measure a cross-correlation peak with the temporal width of 90 fs.
Abstract Properties of intense twin beams generated in parametric down-conversion in periodically poled LiNbO3 crystals and their chirped variants by intense pump fields are analyzed along the model of intense parametric down-conversion that allows for pump depletion and uses the dual spatio-spectral Schmidt modes. Spectral and spatial intensity auto- and cross-correlation functions are determined as they depend on the pump power. Temporal correlations in intense twin beams at the fs time scale are investigated using the Hong-Ou-Mandel interferometer and the process of sum-frequency generation.
Broadband quantum light is a vital resource for quantum metrology and spectroscopy applications such as quantum optical coherence tomography or entangled two photon absorption. For entangled two photon absorption in particular, very high photon flux combined with high time-frequency entanglement is crucial for observing a signal. So far these conditions could be met by using high power lasers driving degenerate, type 0 bulk-crystal spontaneous parametric down conversion (SPDC) sources. This naturally limits the available wavelength ranges and precludes deterministic splitting of the generated output photons. In this work we demonstrate an integrated two-colour SPDC source utilising a group-velocity matched lithium niobate waveguide, reaching both exceptional brightness 1.52⋅10 6 pairssmWGHz and large bandwidth (7.8 THz FWHM) while pumped with a few mW of continuous wave (CW) laser light. By converting a narrow band pump to broadband pulses the created photon pairs show correlation times of Δ τ ≈ 120 fs while maintaining the narrow bandwidth Δ ω p ≪ 1 MHz of the CW pump light, yielding strong time-frequency entanglement. Furthermore our process can be adapted to a wide range of central wavelengths.
We introduce an ultrafast, bright, entangled twin-beam source generated by type-0 parametric down-conversion in periodically-poled lithium niobate at MHz repetition rate, with continuously tunable Schmidt number K set by the pump pulse duration. Photon-number statistics characterization via g(2)(0) and singular-value decomposition of the signal spectral density matrix yield K≃1.05 and K≃1.03, respectively, maintained over multiple orders of magnitude in brightness. Group-delay dispersion of the pump drives a continuous transition from single-mode operation to a controlled multimode regime, consistent with the temporal gain window departing from the inverse phase-matching bandwidth. Strong non-degeneracy of the source (signal at 1.37 um, idler at 4.0 um, ∼100 fs duration) decouples a mid-infrared interaction wavelength, which overlaps with molecular vibrational resonances, from a near-infrared detection band, establishing a practical platform for quantum-enhanced metrology, nonlinear interferometry, and mid-infrared spectroscopic sensing. We show that in the bright few-mode limit, the total entanglement resource is clearly separated between modal and occupational degrees of freedom, and that our source allocates up to 95-97% of that resource to the occupational sector.
We introduce an ultrafast, bright, entangled twin-beam source generated by type-0 parametric down-conversion in periodically-poled lithium niobate at MHz repetition rate, with continuously tunable Schmidt number K set by the pump pulse duration. Photon-number statistics characterization via g(2)(0) and singular-value decomposition of the signal spectral density matrix yield K ~ 1.05 and K ~ 1.03, respectively, maintained over multiple orders of magnitude in brightness. Group-delay dispersion of the pump drives a continuous transition from single-mode operation to a controlled multimode regime, consistent with the temporal gain window departing from the inverse phase-matching bandwidth. Strong non-degeneracy of the source (signal at 1.37 µm, idler at 4.0 µm, ~ 100 fs duration) decouples a mid-infrared interaction wavelength, which overlaps with molecular vibrational resonances, from a near-infrared detection band, establishing a practical platform for quantum-enhanced metrology, nonlinear interferometry, and mid-infrared spectroscopic sensing. We show that in the bright few-mode limit, the total entanglement resource is clearly separated between modal and occupational degrees of freedom, and that our source allocates up to 95-97% of that resource to the occupational sector.
We introduce an ultrafast, bright, entangled twin-beam source generated by type-0 parametric down-conversion in periodically-poled lithium niobate at MHz repetition rate, with continuously tunable Schmidt number K set by the pump pulse duration. Photon-number statistics characterization via g(2)(0) and singular-value decomposition of the signal spectral density matrix yield K ~ 1.05 and K ~ 1.03, respectively, maintained over multiple orders of magnitude in brightness. Group-delay dispersion of the pump drives a continuous transition from single-mode operation to a controlled multimode regime, consistent with the temporal gain window departing from the inverse phase-matching bandwidth. Strong non-degeneracy of the source (signal at 1.37 µm, idler at 4.0 µm, ~ 100 fs duration) decouples a mid-infrared interaction wavelength, which overlaps with molecular vibrational resonances, from a near-infrared detection band, establishing a practical platform for quantum-enhanced metrology, nonlinear interferometry, and mid-infrared spectroscopic sensing. We show that in the bright few-mode limit, the total entanglement resource is clearly separated between modal and occupational degrees of freedom, and that our source allocates up to 95-97% of that resource to the occupational sector.
Summary form only given. In aperiodically poled quasi-phase-matching (QPM) crystals, parametric down-conversion (PDC) can generate very broadband pulsed squeezed light. This is because each part of the crystal will generate squeezed light at a different frequency [1]. But the emission will be thus inhomogeneously broadened, and one requires special measures to eliminate the chirp accompanying the pulses. This can be done by placing a group-velocity dispersion material after the crystal [2] or by specially designing the nonlinear grating [3]. If the bandwidth of squeezed light is large enough, the squeezing and photon-number correlations, after the chirp is removed, will be “single-cycle”, with the correlation time comparable to one optical cycle [4].In this work, the first results on such broadband squeezing are demonstrated. In the 5-mm-long aperiodically poled MgO:LiNbO3 crystal we use, the QPM grating period changes from 7.38 μm to 8.91 μm. With this device, we generated bright twin beams through collinear frequency-nondegenerate high-gain PDC. The phase chirp was eliminated through the design of the nonlinear grating. The frequency bandwidth was measured to be 17 THz, a factor of 15 larger than in a periodically poled crystal. The correlation time was measured using non-phase matched sum frequency generation from the signal and idler beams. The dependence of the sum frequency intensity on the time delay between the signal and idler beams is shown in Fig.1. Fine-resolution scanning (b) shows a narrow peak, demonstrating a correlation time of 90 fs. It can be further reduced by using more advanced grating designs.