Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2610.31717

In situ enhanced detectability of axions' responses in a microwave cavity

Li Gao, Suirong He, Hao Zheng, Ni Chen, Xianing Feng, Qingquan Jiang, Jin Li, L. F. Wei

hep-phhep-thquant-phSubmitted Oct 22, 2026• Announced Oct 23, 2026
arXivHTMLPDF

Abstract

Microwave cavities in strong magnetic fields are among the most sensitive detectors for axion dark matter detection. Its sensitivity, however, is fundamentally limited by the second order nature of axion photon energy conversion, which yields an extremely weak signal. Here we propose a feasible approach to break this limitation, by pre-exciting the target cavity mode to generate a first order power response signal in situ. The resulting signal amplitude scales linearly with the axion-photon coupling parameter, which is in sharp contrast to the quadratic scaling of conventional schemes, and is detectable via standard quadrature balanced homodyne detection system, even though its phase remains stochastic. Numerical simulations demonstrate that this pre-excited seed field can effectively suppress thermal noise, and thus the detection sensitivity of the system can approach the lower quantum noise limit. Consequently, the sensitivities predicted by the KSVZ and DFSZ models could be surpassed. This proposal might offer a pathway to a major leap in axion dark matter searches, as it is within reach of current technology.

AI Summary

The paper asks whether coherently pre-exciting an axion haloscope’s target mode can improve readout of its weak electromagnetic response without changing the underlying axion–photon conversion mechanism. It models a driven cylindrical microwave cavity in a static axial magnetic field, with a seed field in the $\mathrm{TM}_{010}$ mode. Interference between the seed and axion-induced fields produces a power cross term proportional to $g_{a\gamma\gamma}$, rather than the conventional signal power proportional to $g_{a\gamma\gamma}^2$. An axion-modified Maxwell-equation calculation gives the cavity response, while a proposed quadrature-balanced homodyne receiver extracts the interference amplitude despite the stochastic axion phase. For a 1 GHz, 5.13 L cavity with $\bar B=8$ T, $Q=10^4$, and a 3 nT seed, the reported cross-term amplitude is $3.24\times10^{-17}$ W, compared with $3.63\times10^{-25}$ W for conventional conversion power. Sensitivity estimates combine pump amplitude and phase noise, photon shot noise, and thermal and transmission-chain noise using a radiometer model. The resulting projections claim sensitivity below the KSVZ and DFSZ predictions across 300 MHz–10 GHz at room temperature, with 100 s integration and 100 Hz bandwidth. The analysis identifies pump noise as the principal limitation and gives a seed-field operating range of approximately 3–10 nT: stronger pumping degrades sensitivity. It treats pump-noise spectra as assumed external parameters, assumes independent noise sources, and neglects axion spatial gradients. The claimed thermal-noise suppression means thermal noise becomes negligible relative to pump-induced noise; the results are theoretical and numerical, without an experimental demonstration.

Some signs of AI-generated textOverclaimsMissing comparisonUnclear noveltyPossible error

Central claim may not hold: The linear-in-g term is interference with an injected seed, not enhanced axion conversion, and its larger amplitude alone does not establish improved sensitivity. The thermal-noise advantage is unsupported because making pump noise dominant does not suppress thermal fluctuations, and Appendix D discards zero-mean carrier–noise beating terms whose nonzero variance contributes to detection noise. The paper's stated pump noise and explicit noise-temperature definition give approximately 8 × 10^8 K rather than the claimed 0.7 K. The stated signal, pump noise, bandwidth and integration time give an SNR of approximately 0.003 under the paper's own equation, below its detection threshold of one. The noiseless IQ magnitude reconstruction does not justify the sensitivity calculation for a noisy stochastic axion field, because magnitude bias, noise variance and averaging across coherence intervals are not correctly established.

Written by gpt-6.1-sol from the paper's full text. Automated: it can be wrong.

Comments
10 pages, 4 figures

Related papers

Quantum-enhanced dark matter detection with in-cavity control: mitigating the Rayleigh curse

Haowei Shi, Anthony J. Brady, Wojciech Górecki +3 more

The nature of dark matter is a fundamental puzzle in modern physics. A major approach of searching for dark matter relies on detecting feeble noise in microwave cavities. However, the quantum advantages of common quantum resources such as squeezing are intrinsically limited by the Rayleigh curse—a constant loss places a sensitivity upper bound on these quantum resources. In this paper, we propose an in situ transient control to mitigate such Rayleigh limit. The protocol consists of three steps: in-cavity quantum state preparation, axion accumulation with tunable time duration, and measurement. For the quantum source, we focus on the single-mode squeezed state (SMSS), and the entanglement-assisted case using signal-ancilla pairs in two-mode squeezed state (TMSS), where the ancilla does not interact with the axion. From quantum Fisher information rate evaluation, we derive the requirement of cavity quality factor, thermal noise level and squeezing gain for quantum advantage. When the squeezing gain becomes larger, the optimal axion accumulation time decreases, which reduces loss and mitigates the Rayleigh curse—i.e., the quantum advantage increases with the squeezing gain. Overall, we find that TMSS is more sensitive in the low-temperature limit. In the case of SMSS, as large gain is required for an advantage over vacuum, homodyne detection is sufficient to achieve optimality. Whereas, for TMSS, anti-squeezing and photon counting is optimal. Thanks to recent advances in magnetic field-resilient in-cavity squeezing and rapidly coupling out for photon counting, the proposed protocol is compatible with axion detection scenario.

arXiv:2409.04656•npj Quantum Information•Mar 17, 2025•9 citations

Squeezed Vacuum Used to Accelerate the Search for a Weak Classical Signal

M. Malnou, Daniel Palken, Benjamin Brubaker +3 more

Many experiments that interrogate fundamental theories require detectors whose sensitivities are limited by the laws of quantum mechanics.In cavity-based searches for axionic dark matter, vacuum fluctuations in the two quadratures of the cavity electromagnetic field limit the sensitivity to an axion-induced field.In an apparatus designed to partially mimic existing axion detectors, we demonstrate experimentally that such quantum limits can be overcome through the use of squeezed states.By preparing a microwave cavity in a squeezed state and measuring just the squeezed quadrature, we enhance the spectral scan rate by a factor of 2.12 Æ 0.08.This enhancement is in excellent quantitative agreement with a theoretical model accounting for both imperfect squeezing and measurement.

arXiv:1809.06470•Physical Review X•May 3, 2019•114 citations

Boosting Axion Searches with Quantum Sensing

Claudio D. Gatti

The axion, a pseudoscalar particle originally introduced by Peccei, Quinn, Weinberg, and Wilczek to solve the "strong CP problem", is a well motivated dark-matter candidate with a mass lying in a broad range from peV to few meV. The last decade witnessed an increasing interest in axions and axion-like particles with many theoretical works published and many new experimental proposals. A major challenge for cosmological-axion discovery is the detection of the faint signal expected in detectors with power as low as a fraction of yoctowatt corresponding to a single microwave photon per minute. Early experiments used GaAs field-effect-transistors as well as pioneering technology such as Rydberg-atom single-photon detection. In the attempt of reducing the noise temperature superconductive devices were soon introduced. Microstrip SQUID Amplifiers allowed SQUIDs to operate at frequencies of a few GHz with a noise temperature reaching the standard quantum limit. Josephson Parametric Amplifiers have been recently employed extending the search to higher frequency while boradband Traveling Wave Parametric Amplifiers are now under study. The ultimate sensitivity, beyond the quantum limit, is however expected from single microwave-photon detectors. Solutions for quantum sensing include quantum non-demolition measurements and switching detectors based on superconducting qubits and hot-electron detectors. A further improvement in signal sensitivity and noise reduction is expected exploiting arrays of superconducting qubits as proposed by the SUPERGALAX project.

IEEE Workshop on Low Temperature Electronics (WOLTE)•Apr 12, 2021•1 citation

Wide-Mass-Scanning-Range Setup and Phase-Resolved Protocol for Axion Dark Matter Detection

A. Cottet, T. Kontos

We propose a paradigm for quantum enhanced axion dark matter search, which does not rely on power measurements. We propose to measure directly the axion amplitude and phase in an interferometric protocol at the quantum limit, using a non-linear cavity. In addition, we introduce gyromagnetic modes as wide mass range transducers for axion signals compatible with standard haloscope designs. We expect this scheme to offer an improvement of at least 4 orders of magnitude in figure of merit and at least 2 orders of magnitude in mass window with respect to standard haloscopes. Owing to its generality, our proposed protocol has the potential to speed up axion search but also the search for dark photons or other cosmological objects, such as galactic masers.

hep-phCross-listedarXiv:2609.32554•Sep 29, 2026

Quantum-Enhanced Sensing of Axion Dark Matter with a Transmon-Based Single Microwave Photon Counter

C. Braggio, Léo Balembois, R. Di Vora +10 more

We report an axion dark matter search with a haloscope equipped with a microwave photon counter. The haloscope is a tunable high quality factor three-dimensional microwave cavity placed in a magnetic field. The photon counter, operated cyclically, maps an incoming microwave photon onto the state of a superconducting transmon qubit. The measurement protocol continuously monitors the power emitted by the haloscope cavity as well as the dark count background and enables tuning of the cavity frequency to probe different axion masses. With this apparatus, we enhance by a factor of 20 the search speed that can be reached with quantum-limited linear amplifiers and set a new standard for probing the existence of axions with resonant detectors above 5 GHz.

arXiv:2403.02321•Physical Review X•Apr 28, 2025•54 citations

Benchmarking Dark Matter Search using a Parity-Check Protocol with Machine-Learning Optimized Pulses

Yu-Han Chang, Ilya Moskalenko, Marko Kuzmanović +7 more

We report on an improved microwave detection protocol for dark matter candidates such as the axion and the dark photon. We employ a superconducting transmon qubit dispersively coupled to a double-cavity system, enabling quantum non-demolition measurements of the photon occupation in a relatively short-lived storage cavity. To reduce the experimental cycle time and enhance sensitivity for axion and dark-photon searches, we operate this detector in a regime of increased qubit-cavity coupling, resulting in Stark shifts of 4.6 MHz. In this regime, conventional control pulses suffer from strong frequency-detuning sensitivity and photon-number-dependent errors. We address this limitation by implementing frequency-detuning-robust $π/2$ pulses (obtained by machine-learning optimization) that preserve high-fidelity qubit control over a bandwidth of approximately 20 MHz. We experimentally validate this protocol and demonstrate single-photon detection performance comparable to previous implementations, despite significantly reduced qubit coherence times and storage-cavity lifetimes. Using parity-based measurement sequences combined with a Hidden Markov Model (HMM) analysis, we achieve background rates on the order of $\mathcal{O}(20)$ Hz. In the absence of a magnetic field, we derive exclusion limits on the dark photon model for dark matter, reaching a sensitivity to the kinetic mixing angle of $ε_{95\%} \sim 1\times10^{-14}$ at 5.051 GHz. These results establish machine-learning robust control as a key enabler for faster, more scalable microwave quantum sensors for dark-matter searches.

quant-pharXiv:2606.25795•Physical review. D/Physical review. D.•Jun 25, 2026•0 citations
Microwave cavities in strong magnetic fields are among the most sensitive detectors for axion dark matter detection. Its sensitivity, however, is fundamentally limited by the second order nature of axion photon energy conversion, which yields an extremely weak signal. Here we propose a feasible approach to break this limitation, by pre-exciting the target cavity mode to generate a first order power response signal in situ. The resulting signal amplitude scales linearly with the axion-photon coupling parameter, which is in sharp contrast to the quadratic scaling of conventional schemes, and is detectable via standard quadrature balanced homodyne detection system, even though its phase remains stochastic. Numerical simulations demonstrate that this pre-excited seed field can effectively suppress thermal noise, and thus the detection sensitivity of the system can approach the lower quantum noise limit. Consequently, the sensitivities predicted by the KSVZ and DFSZ models could be surpassed. This proposal might offer a pathway to a major leap in axion dark matter searches, as it is within reach of current technology.
The paper asks whether coherently pre-exciting an axion haloscope’s target mode can improve readout of its weak electromagnetic response without changing the underlying axion–photon conversion mechanism. It models a driven cylindrical microwave cavity in a static axial magnetic field, with a seed field in the TM010\mathrm{TM}_{010}TM010​ mode. Interference between the seed and axion-induced fields produces a power cross term proportional to gaγγg_{a\gamma\gamma}gaγγ​, rather than the conventional signal power proportional to gaγγ2g_{a\gamma\gamma}^2gaγγ2​.
An axion-modified Maxwell-equation calculation gives the cavity response, while a proposed quadrature-balanced homodyne receiver extracts the interference amplitude despite the stochastic axion phase. For a 1 GHz, 5.13 L cavity with Bˉ=8\bar B=8Bˉ=8 T, Q=104Q=10^4Q=104, and a 3 nT seed, the reported cross-term amplitude is 3.24×10−173.24\times10^{-17}3.24×10−17 W, compared with 3.63×10−253.63\times10^{-25}3.63×10−25 W for conventional conversion power. Sensitivity estimates combine pump amplitude and phase noise, photon shot noise, and thermal and transmission-chain noise using a radiometer model. The resulting projections claim sensitivity below the KSVZ and DFSZ predictions across 300 MHz–10 GHz at room temperature, with 100 s integration and 100 Hz bandwidth.
The analysis identifies pump noise as the principal limitation and gives a seed-field operating range of approximately 3–10 nT: stronger pumping degrades sensitivity. It treats pump-noise spectra as assumed external parameters, assumes independent noise sources, and neglects axion spatial gradients. The claimed thermal-noise suppression means thermal noise becomes negligible relative to pump-induced noise; the results are theoretical and numerical, without an experimental demonstration.
The nature of dark matter is a fundamental puzzle in modern physics. A major approach of searching for dark matter relies on detecting feeble noise in microwave cavities. However, the quantum advantages of common quantum resources such as squeezing are intrinsically limited by the Rayleigh curse—a constant loss places a sensitivity upper bound on these quantum resources. In this paper, we propose an in situ transient control to mitigate such Rayleigh limit. The protocol consists of three steps: in-cavity quantum state preparation, axion accumulation with tunable time duration, and measurement. For the quantum source, we focus on the single-mode squeezed state (SMSS), and the entanglement-assisted case using signal-ancilla pairs in two-mode squeezed state (TMSS), where the ancilla does not interact with the axion. From quantum Fisher information rate evaluation, we derive the requirement of cavity quality factor, thermal noise level and squeezing gain for quantum advantage. When the squeezing gain becomes larger, the optimal axion accumulation time decreases, which reduces loss and mitigates the Rayleigh curse—i.e., the quantum advantage increases with the squeezing gain. Overall, we find that TMSS is more sensitive in the low-temperature limit. In the case of SMSS, as large gain is required for an advantage over vacuum, homodyne detection is sufficient to achieve optimality. Whereas, for TMSS, anti-squeezing and photon counting is optimal. Thanks to recent advances in magnetic field-resilient in-cavity squeezing and rapidly coupling out for photon counting, the proposed protocol is compatible with axion detection scenario.
Many experiments that interrogate fundamental theories require detectors whose sensitivities are limited by the laws of quantum mechanics.In cavity-based searches for axionic dark matter, vacuum fluctuations in the two quadratures of the cavity electromagnetic field limit the sensitivity to an axion-induced field.In an apparatus designed to partially mimic existing axion detectors, we demonstrate experimentally that such quantum limits can be overcome through the use of squeezed states.By preparing a microwave cavity in a squeezed state and measuring just the squeezed quadrature, we enhance the spectral scan rate by a factor of 2.12 Æ 0.08.This enhancement is in excellent quantitative agreement with a theoretical model accounting for both imperfect squeezing and measurement.
The axion, a pseudoscalar particle originally introduced by Peccei, Quinn, Weinberg, and Wilczek to solve the "strong CP problem", is a well motivated dark-matter candidate with a mass lying in a broad range from peV to few meV. The last decade witnessed an increasing interest in axions and axion-like particles with many theoretical works published and many new experimental proposals. A major challenge for cosmological-axion discovery is the detection of the faint signal expected in detectors with power as low as a fraction of yoctowatt corresponding to a single microwave photon per minute. Early experiments used GaAs field-effect-transistors as well as pioneering technology such as Rydberg-atom single-photon detection. In the attempt of reducing the noise temperature superconductive devices were soon introduced. Microstrip SQUID Amplifiers allowed SQUIDs to operate at frequencies of a few GHz with a noise temperature reaching the standard quantum limit. Josephson Parametric Amplifiers have been recently employed extending the search to higher frequency while boradband Traveling Wave Parametric Amplifiers are now under study. The ultimate sensitivity, beyond the quantum limit, is however expected from single microwave-photon detectors. Solutions for quantum sensing include quantum non-demolition measurements and switching detectors based on superconducting qubits and hot-electron detectors. A further improvement in signal sensitivity and noise reduction is expected exploiting arrays of superconducting qubits as proposed by the SUPERGALAX project.
We propose a paradigm for quantum enhanced axion dark matter search, which does not rely on power measurements. We propose to measure directly the axion amplitude and phase in an interferometric protocol at the quantum limit, using a non-linear cavity. In addition, we introduce gyromagnetic modes as wide mass range transducers for axion signals compatible with standard haloscope designs. We expect this scheme to offer an improvement of at least 4 orders of magnitude in figure of merit and at least 2 orders of magnitude in mass window with respect to standard haloscopes. Owing to its generality, our proposed protocol has the potential to speed up axion search but also the search for dark photons or other cosmological objects, such as galactic masers.
We report an axion dark matter search with a haloscope equipped with a microwave photon counter. The haloscope is a tunable high quality factor three-dimensional microwave cavity placed in a magnetic field. The photon counter, operated cyclically, maps an incoming microwave photon onto the state of a superconducting transmon qubit. The measurement protocol continuously monitors the power emitted by the haloscope cavity as well as the dark count background and enables tuning of the cavity frequency to probe different axion masses. With this apparatus, we enhance by a factor of 20 the search speed that can be reached with quantum-limited linear amplifiers and set a new standard for probing the existence of axions with resonant detectors above 5 GHz.
We report on an improved microwave detection protocol for dark matter candidates such as the axion and the dark photon. We employ a superconducting transmon qubit dispersively coupled to a double-cavity system, enabling quantum non-demolition measurements of the photon occupation in a relatively short-lived storage cavity. To reduce the experimental cycle time and enhance sensitivity for axion and dark-photon searches, we operate this detector in a regime of increased qubit-cavity coupling, resulting in Stark shifts of 4.6 MHz. In this regime, conventional control pulses suffer from strong frequency-detuning sensitivity and photon-number-dependent errors. We address this limitation by implementing frequency-detuning-robust π/2π/2π/2 pulses (obtained by machine-learning optimization) that preserve high-fidelity qubit control over a bandwidth of approximately 20 MHz. We experimentally validate this protocol and demonstrate single-photon detection performance comparable to previous implementations, despite significantly reduced qubit coherence times and storage-cavity lifetimes. Using parity-based measurement sequences combined with a Hidden Markov Model (HMM) analysis, we achieve background rates on the order of O(20)\mathcal{O}(20)O(20) Hz. In the absence of a magnetic field, we derive exclusion limits on the dark photon model for dark matter, reaching a sensitivity to the kinetic mixing angle of ε95%∼1×10−14ε_{95\%} \sim 1\times10^{-14}ε95%​∼1×10−14 at 5.051 GHz. These results establish machine-learning robust control as a key enabler for faster, more scalable microwave quantum sensors for dark-matter searches.